• There are no items in your cart

EN 50289-4-11:2002

Current
Current

The latest, up-to-date edition.

Communication cables - Specifications for test methods - Part 4-11: Environmental test methods - A horizontal integrated fire test method
Published date

03-20-2002

1 Scope
2 Normative references
3 Definitions, symbols and abbreviations
4 Test environment
5 Test apparatus
   5.1 Air-inlet chamber
   5.2 Air-inlet shutter
   5.3 Fire-test chamber
   5.4 Gas burner
   5.5 Removable top cover
   5.6 Exhaust transition
   5.7 Exhaust duct
   5.8 Exhaust duct velocity measurement system
   5.9 Smoke measurement system
   5.10 Smoke release rate measurement system
   5.11 Exhaust duct damper
   5.12 Exhaust blower
   5.13 Fire-test chamber airflow system
   5.14 Ladder cable tray
   5.15 Fire-test chamber temperature measurement
        instruments
   5.16 Data acquisition equipment
   5.17 Heat release rate measurement system
6 Test specimens
7 Calibration and maintenance of test equipment
   7.1 Maintenance
   7.2 Frequency of calibration
   7.3 Airflow
        7.3.1 Air leakage test
        7.3.2 Supplemental air leakage test
        7.3.3 Velocity traverse test
   7.4 Smoke measurement system calibration test
   7.5 Fuel
   7.6 Reinforced inorganic cement board test
        7.6.1 Temperature preheat
        7.6.2 Temperature history test
   7.7 Standard insulated conductor test
   7.8 Procedures for calibration of heat release rate
        measurement equipment
        7.8.1 Analyser calibration
        7.8.2 Delay time
        7.8.3 Calibration test
8 Test specimen preparation
   8.1 Specimen conditioning
   8.2 Determination of specimen diameter
   8.3 Number of cable lengths
   8.4 Cable mounting
9 Test procedures
   9.1 Flame propagation distance and smoke measurement
        test procedure
   9.2 Heat release test procedure
   9.3 Time-to-ignition test procedure
   9.4 Flaming droplets/particles test procedure
10 Post-test clean-up and inspection
   10.1 Smoke measurement system post-test procedure
   10.2 Heat release rate post-test procedure
11 Calculations
   11.1 Optical density of smoke
   11.2 Smoke release rate calculation
   11.3 Exhaust duct velocity measurement calculations
   11.4 Exhaust duct volumetric flow rate calculations
   11.5 Heat release rate calculations
        11.5.1 Peak heat release rate
        11.5.2 Total heat released
   11.6 Time-to-ignition calculations
   11.7 Flaming droplets/particles calculations
12 Report
Annex A (normative) Method for determining suitability
                     of oxygen analysers for making heat
                     release measurements
Annex B (informative) Material information list
Annex C (informative) Brick sizes and locations

This Part 4-11 of EN 50289 specifies a horizontal integrated fire test method for determining flame-propagation distance, optical smoke density, total heat release, heat release rate, time to ignition and flaming droplets/particles for communication cables.The cables are tested in a representative installed condition.

Committee
CLC/TC 46X
DocumentType
Standard
PublisherName
European Committee for Standards - Electrical
Status
Current

EN 60695-9-2:2014 Fire hazard testing - Part 9-2: Surface spread of flame - Summary and relevance of test methods
03/318326 DC : DRAFT NOV 2003
UNE-EN 60695-8-2:2017 Fire hazard testing - Part 8-2: Heat release - Summary and relevance of test methods
EN 60695-8-2:2017 Fire hazard testing - Part 8-2: Heat release - Summary and relevance of test methods
I.S. EN 60695-9-2:2014 FIRE HAZARD TESTING - PART 9-2: SURFACE SPREAD OF FLAME - SUMMARY AND RELEVANCE OF TEST METHODS
CEI EN 60695-6-2 : 2013 FIRE HAZARD TESTING - PART 6-2: SMOKE OBSCURATION - SUMMARY AND RELEVANCE OF TEST METHODS
IEC 60695-8-1:2016 Fire hazard testing - Part 8-1: Heat release - General guidance
PD IEC/TR 62222:2012 Fire performance of communication cables installed in buildings
CEI EN 60695-8-1 : 2009 FIRE HAZARD TESTING - PART 8-1: HEAT RELEASE - GENERAL GUIDANCE
UNE-EN 60695-8-1:2017 Fire hazard testing - Part 8-1: Heat release - General guidance
I.S. EN 60695-8-2:2017 FIRE HAZARD TESTING - PART 8-2: HEAT RELEASE - SUMMARY AND RELEVANCE OF TEST METHODS
I.S. EN 60695-6-2:2011 FIRE HAZARD TESTING - PART 6-2: SMOKE OBSCURATION - SUMMARY AND RELEVANCE OF TEST METHODS (IEC 60695-6-2:2011)
UNE-EN 60695-9-2:2014 Fire hazard testing - Part 9-2: Surface spread of flame - Summary and relevance of test methods
IEC TS 60695-9-2:2005 Fire hazard testing - Part 9-2: Surface spread of flame - Summary and relevance of test methods
IEC 60695-6-2:2011 Fire hazard testing - Part 6-2: Smoke obscuration - Summary and relevance of test methods
IEC 60695-9-2:2014 Fire hazard testing - Part 9-2: Surface spread of flame - Summary and relevance of test methods
BS EN 60695-8-1:2017 Fire hazard testing Heat release. General guidance
I.S. EN 60695-8-1:2017 FIRE HAZARD TESTING - PART 8-1: HEAT RELEASE - GENERAL GUIDANCE
DD IEC TS 60695-9-2 : DRAFT 2005 FIRE HAZARD TESTING - PART 9-2: SURFACE SPREAD OF FLAME - SUMMARY AND RELEVANCE OF TEST METHODS
DD IEC TS 60695-6-2 : DRAFT 2005 FIRE HAZARD TESTING - PART 6-2: SMOKE OBSCURATION - SUMMARY AND RELEVANCE OF TEST METHODS
BS EN 60695-9-2:2014 Fire hazard testing Surface spread of flame. Summary and relevance of test methods
BS EN 60695-8-2:2017 Fire hazard testing Heat release. Summary and relevance of test methods
09/30193524 DC : 0 BS EN 62222 - FIRE PERFORMANCE OF COMMUNICATION CABLES INSTALLED IN BUILDINGS - METHODS OF FIRE RETARDANCY
IEC TR 62222:2012 Fire performance of communication cables installed in buildings
UNE-EN 60695-6-2:2012 Fire hazard testing - Part 6-2: Smoke obscuration - Summary and relevance of test methods
IEC TR 60695-8-2:2008 Fire hazard testing - Part 8-2: Heat release - Summary and relevance of test methods
IEC TS 60695-6-2:2005 Fire hazard testing - Part 6-2: Smoke obscuration - Summary and relevance of test methods
13/30277762 DC : 0 BS EN 60695-8-2 IEC 60695-8-2 ED 1.0 - FIRE HAZARD TESTING - PART 8-2: HEAT RELEASE - SUMMARY AND RELEVANCE OF TEST METHODS
BS EN 60695-6-2:2011 Fire hazard testing Smoke obscuration. Summary and relevance of test methods
PD IEC/TR 60695-8-2:2008 Fire hazard testing Heat release. Summary and relevance of test methods
04/30111706 DC : DRAFT MAR 2004 IEC 60695-9-2 ED.2 - FIRE HAZARD TESTING - PART 9-2: SURFACE SPREAD OF FLAME - SUMMARY AND RELEVANCE OF TEST METHODS
EN 60695-6-2 : 2011 FIRE HAZARD TESTING - PART 6-2: SMOKE OBSCURATION - SUMMARY AND RELEVANCE OF TEST METHODS (IEC 60695-6-2:2011)
EN 60695-8-1:2017 Fire hazard testing - Part 8-1: Heat release - General guidance

IEC 60695-4:2012 Fire hazard testing - Part 4: Terminology concerning fire tests for electrotechnical products
EN 60695-4:2012 FIRE HAZARD TESTING - PART 4: TERMINOLOGY CONCERNING FIRE TESTS FOR ELECTROTECHNICAL PRODUCTS (IEC 60695-4:2012)

View more information
Sorry this product is not available in your region.

Access your standards online with a subscription

Features

  • Simple online access to standards, technical information and regulations.

  • Critical updates of standards and customisable alerts and notifications.

  • Multi-user online standards collection: secure, flexible and cost effective.