EN 61009-2-1:1994/A11:1998/corrigendum Mar. 1999

Current

Current

The latest, up-to-date edition.

RESIDUAL CURRENT OPERATED CIRCUIT BREAKERS WITH INTEGRAL OVERCURRENT PROTECTION FOR HOUSEHOLD AND SIMILAR USES (RCBOs) - PART 2-1: APPLICABILITY OF THE GENERAL RULES TO RCBOS' FUNCTIONALLY INDEPENDENT OF LINE VOLTAGE

Published date

03-17-1999

Foreword
Introduction
1 Scope
2 Normative references
3 Definitions
4 Classification
5 Characteristics of RCBO's
6 Marking and other product information
7 Standard conditions for operation in service and for
  installation
8 Requirements for construction and operation
9 Tests

Applies to residual current operated circuit breakers with integral overcurrent protection (RCBO's) functionally independent of line voltages, for household and similar uses incorporating overcurrent protection having rated voltages not exceeding 440 V a.c., rated currents not exceeding 125 A and rated short-circuit capacities not exceeding 25 000 A, for operation at 50 Hz or 60 Hz.

Committee
TC 23E
DocumentType
Standard
PublisherName
European Committee for Standards - Electrical
Status
Current

UNE-HD 50573.5.57:2014 Co-ordination of electrical equipment for protection, isolation, switching and control
CEI EN 60670-24 : 2014 BOXES AND ENCLOSURES FOR ELECTRICAL ACCESSORIES FOR HOUSEHOLD AND SIMILAR FIXED ELECTRICAL INSTALLATIONS - PART 24: PARTICULAR REQUIREMENTS FOR ENCLOSURES FOR HOUSING PROTECTIVE DEVICES AND OTHER POWER DISSIPATING ELECTRICAL EQUIPMENT
EN 60670-24:2013 Boxes and enclosures for electrical accessories for household and similar fixed electrical installations - Part 24: Particular requirements for enclosures for housing protective devices and other power dissipating electrical equipment
UNE-EN 60670-24:2013 Boxes and enclosures for electrical accessories for household and similar fixed electrical installations - Part 24: Particular requirements for enclosures for housing protective devices and other power dissipating electrical equipment
06/30146388 DC : DRAFT FEB 2006 CENELEC TS 61643-12 - LOW-VOLTAGE SURGE PROTECTIVE DEVICES - PART 12: SURGE PROTECTIVE DEVICES CONNECTED TO LOW-VOLTAGE POWER SYSTEMS - SELECTION AND APPLICATION PRINCIPLES
BS EN 60670-24:2013 Boxes and enclosures for electrical accessories for household and similar fixed electrical installations Particular requirements for enclosures for housing protective devices and other power dissipating electrical equipment
12/30270562 DC : 0 BS EN 60670-24 - BOXES AND ENCLOSURES FOR ELECTRICAL ACCESSORIES FOR HOUSEHOLD AND SIMILAR FIXED ELECTRICAL INSTALLATIONS - PART 24: PARTICULAR REQUIREMENTS FOR ENCLOSURES FOR HOUSING PROTECTIVE DEVICES AND OTHER POWER DISSIPATING ELECTRICAL EQUIPMENT
I.S. EN 60670-24:2013 BOXES AND ENCLOSURES FOR ELECTRICAL ACCESSORIES FOR HOUSEHOLD AND SIMILAR FIXED ELECTRICAL INSTALLATIONS - PART 24: PARTICULAR REQUIREMENTS FOR ENCLOSURES FOR HOUSING PROTECTIVE DEVICES AND OTHER POWER DISSIPATING ELECTRICAL EQUIPMENT (IEC 60670-24:2011 (MOD))
UNE-HD 60364-5-53:2016 Low-voltage electrical installations - Part 5-53: Selection and erection of electrical equipment - Switchgear and controlgear
S.R. HD 60364-5-537:2016 LOW-VOLTAGE ELECTRICAL INSTALLATIONS - PART 5-53: SELECTION AND ERECTION OF ELECTRICAL EQUIPMENT - DEVICES FOR PROTECTION, ISOLATION, SWITCHING, CONTROL AND MONITORING - CLAUSE 537: ISOLATION AND SWITCHING
HD 60364-5-537:2016/A11:2017 LOW-VOLTAGE ELECTRICAL INSTALLATIONS - PART 5-53: SELECTION AND ERECTION OF ELECTRICAL EQUIPMENT - DEVICES FOR PROTECTION, ISOLATION, SWITCHING, CONTROL AND MONITORING - CLAUSE 537: ISOLATION AND SWITCHING
I.S. HD 50573-5-57:2014 CO-ORDINATION OF ELECTRICAL EQUIPMENT FOR PROTECTION, ISOLATION, SWITCHING AND CONTROL
PREN 60670-24 : DRAFT 2012 BOXES AND ENCLOSURES FOR ELECTRICAL ACCESSORIES FOR HOUSEHOLD AND SIMILAR FIXED ELECTRICAL INSTALLATIONS - PART 24: PARTICULAR REQUIREMENTS FOR ENCLOSURES FOR HOUSING PROTECTIVE DEVICES AND OTHER POWER DISSIPATING ELECTRICAL EQUIPMENT (IEC 60670-24:2011, MODIFIED)
S.R. HD 60364-5-53:2015 LOW-VOLTAGE ELECTRICAL INSTALLATIONS - PART 5-53: SELECTION AND ERECTION OF ELECTRICAL EQUIPMENT - SWITCHGEAR AND CONTROLGEAR
HD 50573-5-57:2014 Co-ordination of electrical equipment for protection, isolation, switching and control
HD 60364-5-53:2015/A11:2017 LOW-VOLTAGE ELECTRICAL INSTALLATIONS - PART 5-53: SELECTION AND ERECTION OF ELECTRICAL EQUIPMENT - SWITCHGEAR AND CONTROLGEAR
UNE-HD 60364-5-537:2017 Low-voltage electrical installations - Part 5-53: Selection and erection of electrical equipment - Devices for protection, isolation, switching, control and monitoring - Clause 537: Isolation and switching

BS EN 61009-1 : 2012 RESIDUAL CURRENT OPERATED CIRCUIT-BREAKERS WITH INTEGRAL OVERCURRENT PROTECTION FOR HOUSEHOLD AND SIMILAR USES (RCBOS) - PART 1: GENERAL RULES
BS IEC 1009-2.2 : 1991 SPECIFICATION FOR RESIDUAL CURRENT OPERATED CIRCUIT-BREAKERS WITH INTEGRAL OVERCURRENT PROTECTION FOR HOUSEHOLD AND SIMILAR USES (RCBO's) - APPLICABILITY OF THE GENERAL RULES TO RCBO's FUNCTIONALLY DEPENDENT ON LINE VOLTAGE

View more information
Sorry this product is not available in your region.

Access your standards online with a subscription

Features

  • Simple online access to standards, technical information and regulations.

  • Critical updates of standards and customisable alerts and notifications.

  • Multi-user online standards collection: secure, flexible and cost effective.