• There are no items in your cart

EN 61811-1:2015

Current

Current

The latest, up-to-date edition.

Electromechanical telecom elementary relays of assessed quality - Part 1: Generic specification and blank detail specification

Published date

03-27-2015

FOREWORD
1 Scope
2 Normative references
3 Terms and definitions
4 Rated values
5 Marking and documentation
6 Preparation of blank detail and detail specifications
7 Quality assessment procedures
8 Test schedule
9 Tests
10 Ordering information
Annex A (informative) - Relay reliability - Failure rate data
Annex B (informative) - Characteristic values of the relay
Annex C (informative) - Blank detail and detail specification
Annex D (informative) - Definition of subgroups
Bibliography
Annex ZA (normative) - Normative references to
         international publications with their corresponding
         European publications

IEC 61811-1:2015 applies to electromechanical telecom elementary relays. Relays according to this standard are provided for the operation in telecommunication applications. However, as electromechanical elementary relays, they are also suitable for particular industrial and other applications. This standard selects from IEC 61810 series and other sources the appropriate methods of test to be used in detail specifications derived from this specification, and contains basic test schedules to be used in the preparation of such specifications in accordance with this standard.Detailed test schedules are contained in the detail specifications.This second edition of IEC 61811-1 cancels and replaces IEC 61811-1 published in 1999, IEC 61811-10 published in 2002, IEC 61811-11 published in 2002, IEC 61811-50 published in 2002, IEC 61811-51 published in 2002, IEC 61811-52 published in 2002, IEC 61811-53 published in 2002, IEC 61811-54 published in 2002, IEC 61811-55 published in 2002, and constitutes a technical revision. This edition includes the following significant technical changes with respect to the previous editions:a) to get one document for telecom relays;b) update all relevant references.

Committee
CLC/SR 94
DevelopmentNote
Supersedes EN 116000-1 (07/1999) Supersedes EN 61811-10, EN 61811-11, EN 61811-50, EN 61811-51, EN 61811-52, EN 61811-53, EN 61811-54 and EN 61811-55. (03/2015)
DocumentType
Standard
PublisherName
European Committee for Standards - Electrical
Status
Current
Supersedes

I.S. EN 61811-51:2002 ELECTROMECHANICAL ALL-OR-NOTHING RELAYS - PART 51: BLANK DETAIL SPECIFICATION - ELECTROMECHANICAL ALL-OR-NOTHING TELECOM RELAYS OF ASSESSED QUALITY - NON-STANDARDIZED TYPES AND CONSTRUCTION
EN 61811-51:2002 Electromechanical all-or-nothing relays - Part 51: Blank detail specification - Electromechanical all-or-nothing telecom relays of assessed quality - Non-standardized types and construction
EN 61811-10:2003 Electromechanical elementary relays of assessed quality - Part 10: Sectional specification - Relays for industrial application
EN 61811-54:2002 Electromechanical all-or-nothing relays - Part 54: Blank detail specification - Electromechanical all-or-nothing telecom relays of assessed quality - Two change-over contacts, 15 mm x 7,5 mm base
BS EN 61811-10:2003 Electromechanical all-or-nothing relays Sectional specification. Relays for industrial application
I.S. EN 61811-50:2002 ELECTROMECHANICAL ALL-OR-NOTHING RELAYS - PART 50: SECTIONAL SPECIFICATION - ELECTROMECHANICAL ALL-OR-NOTHING TELECOM RELAYS OF ASSESSED QUALITY
BS EN 61811-52:2002 Electromechanical all-or-nothing relays Blank detail specification. Electromechanical all-or-nothing telecom relays of assessed quality. Two change-over contacts, 20 mm x 10 mm base
BS EN 61811-53:2002 Electromechanical all-or-nothing relays Blank detail specification. Electromechanical all-or-nothing telecom relays of assessed quality. Two change-over contacts, 14 mm x 9 mm base
BS EN 61811-55:2002 Electromechanical non-specified time all-or-nothing relays of assessed quality Blank detail specification. Electromechanical all-or-nothing telecom relays of assessed quality. Two change-over contacts, 11 mm x 7,5 mm (max.) base
BS EN 61811-54:2002 Electromechanical non-specified time all-or-nothing relays of assessed quality Blank detail specification. Electromechanical all-or-nothing telecom relays of assessed quality. Two change-over contacts, 15 mm x 7,5 mm base
BS EN 61811-11:2003 Electromechanical all-or-nothing relays Blank detail specification. Relays for industrial application
BS EN 61811-50:2002 Electromechanical all-or-nothing relays Sectional specification. Electromechanical all-or-nothing telecom relays of assessed quality
I.S. EN 61811-10:2003 ELECTROMECHANICAL ELEMENTARY RELAYS OF ASSESSED QUALITY - PART 10: SECTIONAL SPECIFICATION - RELAYS FOR INDUSTRIAL APPLICATION
IEC 61811-54:2002 Electromechanical all-or-nothing relays - Part 54: Blank detail specification - Electromechanical all-or-nothing telecom relays of assessed quality - Two change-over contacts, 15 mm x 7,5 mm base
EN 61811-52:2002 Electromechanical all-or-nothing relays - Part 52: Blank detail specification - Electromechanical all-or-nothing telecom relays of assessed quality - Two change-over contacts, 20 mm x 10 mm base
BS EN 61811-51:2002 Electromechanical all-or-nothing relays Blank detail specification. Electromechanical all-or-nothing telecom relays of assessed quality. Non-standardized types and construction
I.S. EN 61811-54:2002 ELECTROMECHANICAL ALL-OR-NOTHING RELAYS - PART 54: BLANK DETAIL SPECIFICATION - ELECTROMECHANICAL ALL-OR-NOTHING TELECOM RELAYS OF ASSESSED QUALITY - TWO CHANGE-OVER CONTACTS, 15 MM X 7,5 MM BASE
I.S. EN 61811-53:2002 ELECTROMECHANICAL ALL-OR-NOTHING RELAYS - PART 53: BLANK DETAIL SPECIFICATION - ELECTROMECHANICAL ALL-OR-NOTHING TELECOM RELAYS OF ASSESSED QUALITY - TWO CHANGE-OVER CONTACTS, 14 MM X 9 MM BASE
I.S. EN 61811-11:2003 ELECTROMECHANICAL ELEMENTARY RELAYS OF ASSESSED QUALITY - PART 11: BLANK DETAIL SPECIFICATION - RELAYS FOR INDUSTRIAL APPLICATION
I.S. EN 61811-52:2002 ELECTROMECHANICAL ALL-OR-NOTHING RELAYS - PART 52: BLANK DETAIL SPECIFICATION - ELECTROMECHANICAL ALL-OR-NOTHING TELECOM RELAYS OF ASSESSED QUALITY - TWO CHANGE-OVER CONTACTS, 20 MM X 10 MM BASE
I.S. EN 61811-55:2002 ELECTROMECHANICAL ALL-OR-NOTHING RELAYS - PART 55: BLANK DETAIL SPECIFICATION - ELECTROMECHANICAL ALL-OR-NOTHING TELECOM RELAYS OF ASSESSED QUALITY - TWO CHANGE-OVER CONTACTS, 11 MM X 7,5 MM (MAX.) BASE
EN 61811-11:2003 Electromechanical elementary relays of assessed quality - Part 11: Blank detail specification - Relays for industrial application
EN 61811-50:2002 Electromechanical all-or-nothing relays - Part 50: Sectional specification - Electromechanical all-or-nothing telecom relays of assessed quality

IEC 60068-1:2013 Environmental testing - Part 1: General and guidance
IEC 60068-2-58:2015+AMD1:2017 CSV Environmental testing - Part 2-58: Tests - Test Td: Test methods for solderability, resistance to dissolution of metallization and to soldering heat of surface mounting devices (SMD)
IEC 60068-2-20:2008 Environmental testing - Part 2-20: Tests - Test T: Test methods for solderability and resistance to soldering heat of devices with leads
EN 60068-2-20:2008 Environmental testing - Part 2-20: Tests - Test T: Test methods for solderability and resistance to soldering heat of devices with leads
IEC 61649:2008 Weibull analysis
EN 60068-1:2014 Environmental testing - Part 1: General and guidance
IEC 61810-1:2015 Electromechanical elementary relays - Part 1: General and safety requirements
EN 61810-2:2017 Electromechanical elementary relays - Part 2: Reliability
EN 61810-7:2006 Electromechanical elementary relays - Part 7: Test and measurement procedures
IEC 61810-7:2006 Electromechanical elementary relays - Part 7: Test and measurement procedures
IEC 60410:1973 Sampling plans and procedures for inspection by attributes
IEC 61810-2:2017 Electromechanical elementary relays - Part 2: Reliability
IEC 60068-2-47:2005 Environmental testing - Part 2-47: Test - Mounting of specimens for vibration, impact and similar dynamic tests
ISO 8601:2004 Data elements and interchange formats Information interchange Representation of dates and times
EN 60068-2-17:1994 Environmental testing - Part 2: Tests - Test Q: Sealing
IEC 60068-2-17:1994 Basic environmental testing procedures - Part 2-17: Tests - Test Q: Sealing
IEC 61709:2017 Electric components - Reliability - Reference conditions for failure rates and stress models for conversion
IEC 60062:2016 Marking codes for resistors and capacitors
IEC 61709 : 3.0 ELECTRIC COMPONENTS - RELIABILITY - REFERENCE CONDITIONS FOR FAILURE RATES AND STRESS MODELS FOR CONVERSION
EN 60062:2016/AC:2016-12 MARKING CODES FOR RESISTORS AND CAPACITORS (IEC 60062:2016/COR1:2016)
ISO 9001:2015 Quality management systems — Requirements
EN 60695-11-5:2017 Fire hazard testing - Part 11-5: Test flames - Needle-flame test method - Apparatus, confirmatory test arrangement and guidance
IEC 60695-11-5 : 2.0 FIRE HAZARD TESTING - PART 11-5: TEST FLAMES - NEEDLE-FLAME TEST METHOD - APPARATUS, CONFIRMATORY TEST ARRANGEMENT AND GUIDANCE
IEC 60695-11-5:2016 Fire hazard testing - Part 11-5: Test flames - Needle-flame test method - Apparatus, confirmatory test arrangement and guidance

View more information
Sorry this product is not available in your region.

Access your standards online with a subscription

Features

  • Simple online access to standards, technical information and regulations.

  • Critical updates of standards and customisable alerts and notifications.

  • Multi-user online standards collection: secure, flexible and cost effective.