• There are no items in your cart

EN ISO 10993-18:2009

Superseded
Superseded

A superseded Standard is one, which is fully replaced by another Standard, which is a new edition of the same Standard.

View Superseded by
superseded

A superseded Standard is one, which is fully replaced by another Standard, which is a new edition of the same Standard.

Biological evaluation of medical devices - Part 18: Chemical characterization of materials (ISO 10993-18:2005)
Superseded date

06-08-2020

Published date

04-29-2009

Foreword
Introduction
1 Scope
2 Normative references
3 Terms and definitions
4 Symbols and abbreviated terms
5 General principles
6 Characterization procedure
  6.1 General
  6.2 Step 1 - Qualitative information
  6.3 Step 2 - Material equivalence
  6.4 Step 3 - Quantitative information
  6.5 Step 4 - Quantitative risk assessment
  6.6 Step 5 - Estimated clinical exposure to chemicals
      present
7 Chemical characterization parameters and methods
  7.1 General
  7.2 Polymers
  7.3 Metals and alloys
  7.4 Ceramics
  7.5 Natural macromolecules
8 Reporting of data obtained
Annex A (normative) - Flowchart summarizing the stepwise
        generation of chemical characterization data for
        use in toxicological risk assessment
Annex B (informative) - Information sources for chemical
        characterization
Annex C (informative) - Principles for judging toxicological
        equivalency
Bibliography
Annex ZA (informative) - Relationship between this European
         Standard and the Essential Requirements of EU
         Directive 93/42/EEC on Medical Devices
Annex ZB (informative) - Relationship between this European
         Standard and the Essential Requirements of EU
         Directive 90/385/EEC on Active Implantable
         Medical Devices

ISO 10993-18:2005 describes a framework for the identification of a material and the identification and quantification of its chemical constituents. The chemical characterization information generated can be used for a range of important applications, for example, as part of an assessment of the overall biological safety of a medical device (ISO 10993-1 and 14971), as a measurement of the level of a leachable substance in a medical device in order to allow the assessment of compliance with the allowable limit derived for that substance from health based risk assessment (ISO 10993-17), for judging equivalence of a proposed material to a clinically established material, for judging equivalence of a final device to a prototype device to check the relevance of data on the latter to be used to support the assessment of the former, or for screening of potential new materials for suitability in a medical device for a proposed clinical application. ISO 10993-18:2005 does not address the identification or quantification of degradation products, which is covered in ISO 10993-9, ISO 10993-13, ISO 10993-14 and ISO 10993-15.The ISO 10993 series of standards is applicable when the material or device comes into contact with the body directly or indirectly (see 4.2.1 of ISO 10993-1).ISO 10993-18:2005 is intended for suppliers of materials and manufacturers of medical devices, when carrying out a biological safety assessment.

Committee
CEN/TC 206
DocumentType
Standard
PublisherName
Comite Europeen de Normalisation
Status
Superseded
SupersededBy

I.S. EN ISO 7198:2017 CARDIOVASCULAR IMPLANTS AND EXTRACORPOREAL SYSTEMS - VASCULAR PROSTHESES - TUBULAR VASCULAR GRAFTS AND VASCULAR PATCHES (ISO 7198:2016)
UNE-EN ISO 7198:2017 Cardiovascular implants and extracorporeal systems - Vascular prostheses - Tubular vascular grafts and vascular patches (ISO 7198:2016)
VDI 5703:2015-09 Systematical development for a model-based testing of medical devices
BS EN ISO 25539-1:2017 Cardiovascular implants. Endovascular devices Endovascular prostheses
15/30278530 DC : 0 BS ISO 18562-1 - BIOCOMPATIBILITY EVALUATION OF BREATHING GAS PATHWAYS IN HEALTHCARE APPLICATIONS - PART 1: EVALUATION AND TESTING WITHIN A RISK MANAGEMENT PROCESS
15/30278537 DC : 0 BS ISO 18562-3 - BIOCOMPATIBILITY EVALUATION OF BREATHING GAS PATHWAYS IN HEALTHCARE APPLICATIONS - PART 3: TESTS FOR EMISSIONS OF VOLATILE ORGANIC COMPOUNDS (VOCS)
I.S. EN ISO 25539-1:2017 CARDIOVASCULAR IMPLANTS - ENDOVASCULAR DEVICES - PART 1: ENDOVASCULAR PROSTHESES (ISO 25539-1:2017)
EN ISO 7198:2017 Cardiovascular implants and extracorporeal systems - Vascular prostheses - Tubular vascular grafts and vascular patches (ISO 7198:2016)
BS EN ISO 7198:2017 Cardiovascular implants and extracorporeal systems. Vascular prostheses. Tubular vascular grafts and vascular patches

EN 12442-3 : 2000 ANIMAL TISSUES AND THEIR DERIVATIVES UTILIZED IN THE MANUFACTURE OF MEDICAL DEVICES - PART 3: VALIDATION OF THE ELIMINATION AND/OR INACTIVATION OF VIRUSES AND TRANSMISSIBLE AGENTS
ISO 5725-1:1994 Accuracy (trueness and precision) of measurement methods and results — Part 1: General principles and definitions
ISO 5832-1:2016 Implants for surgery — Metallic materials — Part 1: Wrought stainless steel
ISO 10993-13:2010 Biological evaluation of medical devices Part 13: Identification and quantification of degradation products from polymeric medical devices
ISO 10993-2:2006 Biological evaluation of medical devices — Part 2: Animal welfare requirements
EN 455-3:2015 Medical gloves for single use - Part 3: Requirements and testing for biological evaluation
ISO 10993-14:2001 Biological evaluation of medical devices Part 14: Identification and quantification of degradation products from ceramics
ISO 10993-17:2002 Biological evaluation of medical devices — Part 17: Establishment of allowable limits for leachable substances
ISO 10993-1:2009 Biological evaluation of medical devices Part 1: Evaluation and testing within a risk management process
ISO 10993-9:2009 Biological evaluation of medical devices Part 9: Framework for identification and quantification of potential degradation products
EN 12442-1 : 2000 ANIMAL TISSUES AND THEIR DERIVATIVES UTILIZED IN THE MANUFACTURE OF MEDICAL DEVICES - PART 1: ANALYSIS AND MANAGEMENT OF RISK
ISO 14971:2007 Medical devices Application of risk management to medical devices
EN 12442-2 : 2000 ANIMAL TISSUES AND THEIR DERIVATIVES UTILIZED IN THE MANUFACTURE OF MEDICAL DEVICES - PART 2: CONTROLS ON SOURCING, COLLECTION AND HANDLING

View more information
Sorry this product is not available in your region.

Access your standards online with a subscription

Features

  • Simple online access to standards, technical information and regulations.

  • Critical updates of standards and customisable alerts and notifications.

  • Multi-user online standards collection: secure, flexible and cost effective.