EN ISO 7198:2017

Current
Current

The latest, up-to-date edition.

Cardiovascular implants and extracorporeal systems - Vascular prostheses - Tubular vascular grafts and vascular patches (ISO 7198:2016)
Published date

03-01-2017

European foreword
Foreword
Introduction
1 Scope
2 Normative references
3 Terms and definitions
4 General requirements
5 Intended performance
6 Design attributes
7 Materials
8 Design evaluation
9 Preclinical in vivo evaluation test methods for
   vascular prostheses
10 Clinical investigation methods for vascular prostheses
11 Manufacturing
12 Sterility
13 Packaging and labelling
Annex A (informative) - Test methods
Bibliography
Annex ZA (informative) - Relationship between this
         European Standard and the Essential
         Requirements of EU Directive 93/42/EEC
         [OJ L 169] on medical devices

ISO 7198:2016 specifies requirements for the evaluation of vascular prostheses and requirements with respect to nomenclature, design attributes and information supplied by the manufacturer, based upon current medical knowledge. Guidance for the development of in vitro test methods is included in an informative annex to ISO 7198:2016. It can be considered as a supplement to ISO 14630:2012, which specifies general requirements for the performance of non-active surgical implants.NOTE Due to the variations in the design of implants covered by ISO 7198 :2016 and, in some cases, due to the relatively recent development of some of these implants (e.g. bioabsorbable vascular prostheses, cell based tissue engineered vascular prostheses), acceptable standardized in vitro tests and clinical results are not always available. As further scientific and clinical data become available, appropriate revision of ISO 7198 :2016 will be necessary.It is applicable to sterile tubular vascular grafts implanted by direct visualization surgical techniques as opposed to fluoroscopic or other non-direct imaging (e.g. computerized tomography or magnetic resonance imaging), intended to replace, bypass, or form shunts between segments of the vascular system in humans and vascular patches intended for repair and reconstruction of the vascular system.Vascular prostheses that are made of synthetic textile materials and synthetic non-textile materials are within the scope of ISO 7198:2016.While vascular prostheses that are made wholly or partly of materials of non-viable biological origin, including tissue engineered vascular prostheses are within the scope, ISO 7198:2016 does not address sourcing, harvesting, manufacturing and all testing requirements for biological materials. It is further noted that different regulatory requirements might exist for tissues from human and animal sources.Compound, coated, composite, and externally reinforced vascular prostheses are within the scope of ISO 7198:2016.Endovascular prostheses implanted using catheter delivery and non-direct visualization are excluded from the scope of ISO 7198:2016. It includes information on the development of appropriate test methods for graft materials, referenced in ISO 25539‑1 for materials used in the construction of endovascular prostheses (i.e. stent-grafts).NOTE Requirements for endovascular prostheses are specified in ISO 25539‑1.The valve component of valved conduits constructed with a tubular vascular graft component, and the combination of the valved component and the tubular vascular graft component, are excluded from the scope of ISO 7198:2016. It can be helpful in identifying the appropriate evaluation of the tubular vascular graft component of a valved conduit but specific requirements and testing are not described for these devices.Cardiac and pericardial patches, vascular stents, accessory devices such as anastomotic devices, staplers, tunnelers and sutures, and pledgets are excluded from the scope of ISO 7198:2016.NOTE Requirements for vascular stents are specified in ISO 25539‑2.Requirements regarding cell seeding are excluded from the scope of ISO 7198:2016. Tissue engineered vascular prostheses that contain or are manufactured using cells present many distinct manufacturing (e.g. aseptic processing, cell seeding, etc.) and testing issues than those produced with synthetic or non-viable biological materials. The in vitro testing requirements that a

Committee
CEN/TC 285
DevelopmentNote
Supersedes EN 12006-2. (03/2017)
DocumentType
Standard
PublisherName
Comite Europeen de Normalisation
Status
Current
Supersedes

ISO 25539-2:2012 Cardiovascular implants Endovascular devices Part 2: Vascular stents
EN ISO 14937:2009 Sterilization of health care products - General requirements for characterization of a sterilizing agent and the development, validation and routine control of a sterilization process for medical devices (ISO 14937:2009)
EN ISO 10993-5:2009 Biological evaluation of medical devices - Part 5: Tests for in vitro cytotoxicity (ISO 10993-5:2009)
EN ISO 10993-2:2006 Biological evaluation of medical devices - Part 2: Animal welfare requirements (ISO 10993-2:2006)
ISO 14160:2011 Sterilization of health care products Liquid chemical sterilizing agents for single-use medical devices utilizing animal tissues and their derivatives Requirements for characterization, development, validation and routine control of a sterilization process for medical devices
ISO 11135:2014 Sterilization of health-care products Ethylene oxide Requirements for the development, validation and routine control of a sterilization process for medical devices
EN ISO 10993-11:2009 Biological evaluation of medical devices - Part 11: Tests for systemic toxicity (ISO 10993-11:2006)
EN ISO 14155:2011/AC:2011 CLINICAL INVESTIGATION OF MEDICAL DEVICES FOR HUMAN SUBJECTS - GOOD CLINICAL PRACTICE (ISO 14155:2011)
EN ISO 10993-17:2009 Biological evaluation of medical devices - Part 17: Establishment of allowable limits for leachable substances (ISO 10993-17:2002)
ISO 13485:2016 Medical devices Quality management systems Requirements for regulatory purposes
EN ISO 10993-13:2010 Biological evaluation of medical devices - Part 13: Identification and quantification of degradation products from polymeric medical devices (ISO 10993-13:2010)
ISO 14937:2009 Sterilization of health care products General requirements for characterization of a sterilizing agent and the development, validation and routine control of a sterilization process for medical devices
EN ISO 10993-9:2009 Biological evaluation of medical devices - Part 9: Framework for identification and quantification of potential degradation products (ISO 10993-9:2009)
EN ISO 10993-10:2013 Biological evaluation of medical devices - Part 10: Tests for irritation and skin sensitization (ISO 10993-10:2010)
EN ISO 10993-7 : 2008 COR 2009 BIOLOGICAL EVALUATION OF MEDICAL DEVICES - PART 7: ETHYLENE OXIDE STERILIZATION RESIDUALS (ISO 10993-7:2008/COR 1:2009)
EN ISO 10993-4:2017 Biological evaluation of medical devices - Part 4: Selection of tests for interactions with blood (ISO 10993-4:2017)
ISO 25539-1:2017 Cardiovascular implants — Endovascular devices — Part 1: Endovascular prostheses
CEN ISO/TS 17665-2:2009 Sterilization of health care products - Moist heat - Part 2: Guidance on the application of ISO 17665-1 (ISO/TS 17665-2:2009)
EN ISO 11135:2014 Sterilization of health-care products - Ethylene oxide - Requirements for the development, validation and routine control of a sterilization process for medical devices (ISO 11135:2014)
EN ISO 10993-3:2014 Biological evaluation of medical devices - Part 3: Tests for genotoxicity, carcinogenicity and reproductive toxicity (ISO 10993-3:2014)
ISO 14630:2012 Non-active surgical implants General requirements
EN ISO 10993-6:2016 Biological evaluation of medical devices - Part 6: Tests for local effects after implantation (ISO 10993-6:2016)
ISO 12417-1:2015 Cardiovascular implants and extracorporeal systems — Vascular device-drug combination products — Part 1: General requirements
EN ISO 11137-2:2015 Sterilization of health care products - Radiation - Part 2: Establishing the sterilization dose (ISO 11137-2:2013)
EN ISO 10993-18:2009 Biological evaluation of medical devices - Part 18: Chemical characterization of materials (ISO 10993-18:2005)
EN ISO 11137-1:2015 Sterilization of health care products - Radiation - Part 1: Requirements for development, validation and routine control of a sterilization process for medical devices (ISO 11137-1:2006, including Amd 1:2013)
EN ISO 14971:2012 Medical devices - Application of risk management to medical devices (ISO 14971:2007, Corrected version 2007-10-01)
EN ISO 10993-12:2012 Biological evaluation of medical devices - Part 12: Sample preparation and reference materials (ISO 10993-12:2012)
ISO 14155:2011 Clinical investigation of medical devices for human subjects Good clinical practice
EN ISO 17665-1 : 2006 Sterilization of health care products - Moist heat - Part 1: Requirements for the development, validation and routine control of a sterilization process for medical devices (ISO 17665-1:2006)
ISO 14971:2007 Medical devices Application of risk management to medical devices
ISO 11607-1:2006 Packaging for terminally sterilized medical devices Part 1: Requirements for materials, sterile barrier systems and packaging systems
EN ISO 10993-15:2009 Biological evaluation of medical devices - Part 15: Identification and quantification of degradation products from metals and alloys (ISO 10993-15:2000)
EN ISO 10993-14:2009 Biological evaluation of medical devices - Part 14: Identification and quantification of degradation products from ceramics (ISO 10993-14:2001)
EN ISO 10993-1:2009/AC:2010 BIOLOGICAL EVALUATION OF MEDICAL DEVICES - PART 1: EVALUATION AND TESTING WITHIN A RISK MANAGEMENT PROCESS (ISO 10993-1:2009/COR 1:2010)
EN ISO 11137-3:2017 Sterilization of health care products - Radiation - Part 3: Guidance on dosimetric aspects of development, validation and routine control (ISO 11137-3:2017)
EN ISO 14160:2011 Sterilization of health care products - Liquid chemical sterilizing agents for single-use medical devices utilizing animal tissues and their derivatives - Requirements for characterization, development, validation and routine control of a sterilization process for medical devices (ISO 14160:2011)
EN ISO 14630:2012 Non-active surgical implants - General requirements (ISO 14630:2012)

View more information
Sorry this product is not available in your region.

Access your standards online with a subscription

Features

  • Simple online access to standards, technical information and regulations.

  • Critical updates of standards and customisable alerts and notifications.

  • Multi-user online standards collection: secure, flexible and cost effective.