FOREWORD
1 SCOPE
2 NORMATIVE REFERENCES
3 DEFINITIONS
   3.1 APPLIANCE AND ITS CONSTITUENT PARTS
   3.2 ADJUSTING, CONTROL AND SAFETY DEVICES
   3.3 OPERATION OF THE APPLIANCE
   3.4 GASES
   3.5 CONDITIONS OF OPERATION AND MEASUREMENT
   3.6 COUNTRY OF DESTINATION
   3.7 CLASSIFICATION
         3.7.1 Classification of gases
         3.7.2 Classification of appliances
4 CONSTRUCTION AND DESIGN REQUIREMENTS
   4.1 GENERAL
         4.1.1 Conversion to different gases
         4.1.2 Materials and methods of construction
         4.1.3 Accessibility for maintenance and use
         4.1.4 Thermal insulation
         4.1.5 Gas connection
         4.1.6 Soundness of the gas circuit
         4.1.7 Supply and distribution of air
         4.1.8 Checking the state of operation
         4.1.9 Electrical equipment
         4.1.10 Operational safety in the event of
                  fluctuation, interruption, and
                  restoration of the auxiliary energy
         4.1.11 Motors and fans
   4.2 ADJUSTING, CONTROL AND SAFETY DEVICES
         4.2.1 General
         4.2.2 Gas rate adjusters and range-rating
                  devices
         4.2.3 Aeration adjusters
         4.2.4 Manual controls
         4.2.5 Governors
         4.2.6 Multifunctional controls
         4.2.7 Flame supervision devices
         4.2.8 Automatic shut-off valves
         4.2.9 Automatic burner control systems
         4.2.10 Gas strainers
         4.2.11 Air strainers and filters
   4.3 IGNITION DEVICES
         4.3.1 General
         4.3.2 Ignition device for the main burner
         4.3.3 Ignition burners
   4.4 COMBUSTION AND DILUTION AIR, PRE-PURGE AND
         POST-PURGE
   4.5 FLAME SUPERVISION SYSTEM
         4.5.1 Appliances with non-automatic burner
                  systems
         4.5.2 Appliances with automatic burner systems
   4.6 START-GAS FLAME ESTABLISHMENT
         4.6.1 Appliances with non-automatic burner
                  systems
         4.6.2 Appliances with automatic burner systems
   4.7 MAIN FLAME ESTABLISHMENT
         4.7.1 Establishment by means of a start gas
                  flame
         4.7.2 Direct establishment of the main flame
   4.8 MAIN BURNER
   4.9 FACILITY FOR REMOTE CONTROL
   4.10 THERMOSTATS AND CONTROL OF AIR TEMPERATURE
         4.10.1 General
         4.10.2 Control of delivered air temperature
         4.10.3 Overheat cut-off device
         4.10.4 Sensors
   4.11 GAS PRESSURE TEST POINTS
   4.12 FACILITIES FOR COMMISSIONING AND TESTING
         4.12.1 General
         4.12.2 Appliances having reduced start gas rates
   4.13 ADDITIONAL REQUIREMENTS FOR APPLIANCES DESIGNED
         FOR PERMANENT OUTDOOR INSTALLATION OR WHERE
         AUTOMATIC IRRIGATION SYSTEMS ARE USED
         4.13.1 General
         4.13.2 Air inlets (outdoor appliances)
         4.13.3 Access panels and doors
         4.13.4 Dimensions of openings
         4.13.5 Fixing screws
5 OPERATIONAL REQUIREMENTS
   5.1 SOUNDNESS OF THE GAS CIRCUIT
   5.2 HEAT INPUTS
         5.2.1 Nominal heat input
         5.2.2 Start gas heat input
         5.2.3 Effectiveness of gas rate adjusters
         5.2.4 Effectiveness of the gas governor
         5.2.5 Effectiveness of the range-rating device
   5.3 LIMITING TEMPERATURES
         5.3.1 Temperatures of parts that have to be
                  touched during normal use
         5.3.2 Temperatures of the appliance casing
         5.3.3 Component temperatures
         5.3.4 Fan motor winding temperatures
         5.3.5 Maximum temperature of the delivered air
   5.4 IGNITION, CROSS-LIGHTING, FLAME STABILITY
         5.4.1 Ignition and cross-lighting
         5.4.2 Flame stability
   5.5 COMBUSTION
         5.5.1 Appliances designed to be used in
                  greenhouses
         5.5.2 Other appliances
         5.5.3 Combustion air proving device(s)
         5.5.4 CO2 safety device
         5.5.5 Auxiliary energy variations
   5.6 OVERHEAT CUT-OFF DEVICE
   5.7 WATER RESISTANCE
6 TEST METHODS
   6.1 GENERAL
         6.1.1 Characteristics of test gases;
                  reference and limit gases
         6.1.2 Conditions for preparation of the test
                  gases
         6.1.3 Practical application of test gases
         6.1.4 Test pressures
         6.1.5 Test procedures
         6.1.6 General test conditions
   6.2 CONSTRUCTION AND DESIGN
         6.2.1 Automatic burner control systems
                  (manually operated devices)
         6.2.2 Ignition opening time
         6.2.3 Ignition of the ignition burner with
                  the downstream main gas automatic
                  shut-off valve open
         6.2.4 Combustion air proving device(s)
   6.3 SAFETY OF OPERATION
         6.3.1 Soundness of the gas circuit
         6.3.2 Heat inputs
         6.3.3 Limiting temperatures
         6.3.4 Ignition, cross-lighting and flame
                  stability
         6.3.5 Combustion
         6.3.6 Overhead cut-off device
         6.3.7 Water resistance
7 MARKING AND INSTRUCTIONS
   7.1 GENERAL
   7.2 DESCRIPTION
   7.3 DATA PLATE AND LABELLING
   7.4 OTHER MARKING
   7.5 MARKING OF THE PACKAGING
   7.6 UTILIZATION OF SYMBOLS ON THE APPLIANCE AND
         PACKAGING
         7.6.1 Electrical supply
         7.6.2 Type of gas
         7.6.3 Gas supply pressure
         7.6.4 Country of destination
         7.6.5 Category
         7.6.6 Other information
   7.7 INSTRUCTIONS
         7.7.1 General
         7.7.2 Technical instructions for installation
                  and adjustment
         7.7.3 Instructions for conversion
         7.7.4 Instructions for servicing
         7.7.5 Instructions for use and maintenance
         7.7.6 Presentation
ANNEX A (INFORMATIVE) NATIONAL SITUATIONS
      A.1 - CATEGORIES LISTED IN THE BODY OF THE STANDARD AND
            MARKETED IN THE DIFFERENT COUNTRIES
      A.2 - APPLIANCE SUPPLY PRESSURES CORRESPONDING TO THE
            CATEGORIES GIVEN IN A.1
      A.3 - SPECIAL CATEGORIES MARKETED NATIONALLY OR LOCALLY
      A.4 - TEST GASES AND TEST PRESSURES CORRESPONDING TO THE
            SPECIAL GASES GIVEN IN A.3
      A.5 - GAS CONNECTIONS IN THE VARIOUS COUNTRIES
ANNEX B (INFORMATIVE) GUIDANCE FOR LIMITATIONS OF APPLICATION
                      OF DIRECT-FIRED AIR HEATERS IN BUILDINGS
      B.1 - GENERAL PRINCIPLES
      B.2 - SAFE OPERATING EMISSION LEVELS
      B.3 - ASSESSMENT OF CONCENTRATIONS
      B.4 - CASE STUDIES
ANNEX C (INFORMATIVE) A-DEVIATIONS
ANNEX D (NORMATIVE) SPECIAL NATIONAL CONDITIONS
ANNEX ZA (INFORMATIVE) CLAUSES OF THIS EUROPEAN STANDARD
         ADDRESSING REQUIREMENTS OR PROVISIONS
         OF EU DIRECTIVES

Covers the requirements and test methods for the safety of direct gas-fired hot air blowers for greenhouses, agriculturalized or supplementary space heating hereinafter called "appliances".

DocumentType
Standard
Pages
78
PublisherName
National Standards Authority of Ireland
Status
Withdrawn

Standards Relationship
UNI EN 12669 : 2003 Identical
UNE-EN 12669:2001 Identical
SN EN 12669 : 2000 Identical
NBN EN 12669 : 2000 Identical
DIN EN 12669:2000-09 Identical
NS EN 12669 : 1ED 2000 Identical
NEN EN 12669 : 2000 Identical
NF EN 12669 : 2000 Identical
BS EN 12669:2000 Identical
EN 12669:2000 Identical

ISO 7005-2:1988 Metallic flanges — Part 2: Cast iron flanges
EN 50165 : 97 AMD 1 2001 ELECTRICAL EQUIPMENT ON NON-ELECTRIC APPLIANCES FOR HOUSEHOLD AND SIMILAR PURPOSES - SAFETY REQUIREMENTS
ISO 6976:2016 Natural gas — Calculation of calorific values, density, relative density and Wobbe indices from composition
EN 60584-2:1993 Thermocouples - Part 2: Tolerances
EN 60730-2-9:2010 Automatic electrical controls for household and similar use - Part 2-9: Particular requirements for temperature sensing controls
ISO 7005-3:1988 Metallic flanges Part 3: Copper alloy and composite flanges
EN ISO 3166-1:2014 Codes for the representation of names of countries and their subdivisions - Part 1: Country codes (ISO 3166-1:2013)
EN 161:2011+A3:2013 Automatic shut-off valves for gas burners and gas appliances
EN 60742:1995 Isolating transformers and safety isolating transformers - Requirements
ISO 7-1:1994 Pipe threads where pressure-tight joints are made on the threads Part 1: Dimensions, tolerances and designation
EN 437:2003+A1:2009 Test gases - Test pressures - Appliance categories
EN 125:2010+A1:2015 Flame supervision devices for gas burning appliances - Thermoelectric flame supervision devices
EN 126:2012 Multifunctional controls for gas burning appliances
EN 60584-1:2013 Thermocouples - Part 1: EMF specifications and tolerances
EN 60730-2-1 : 97 AMD 11 2005 AUTOMATIC ELECTRICAL CONTROLS FOR HOUSEHOLD AND SIMILAR USE - PART 2-1: PARTICULAR REQUIREMENTS FOR ELECTRICAL CONTROLS FOR ELECTRICAL HOUSEHOLD APPLIANCES
ISO 3166-1:2013 Codes for the representation of names of countries and their subdivisions Part 1: Country codes
EN 61058-1:2002/A2:2008 SWITCHES FOR APPLIANCES - PART 1: GENERAL REQUIREMENTS
EN 60335-1:2012/A13:2017 HOUSEHOLD AND SIMILAR ELECTRICAL APPLIANCES - SAFETY - PART 1: GENERAL REQUIREMENTS (IEC 60335-1:2010, MODIFIED)
EN 298:2012 Automatic burner control systems for burners and appliances burning gaseous or liquid fuels
EN 88:1991/A1:1996 PRESSURE GOVERNORS FOR GAS APPLIANCES FOR INLET PRESSURE UP TO 200 MBAR
ISO 7005-1:2011 Pipe flanges — Part 1: Steel flanges for industrial and general service piping systems
EN 60529:1991/AC:2016-12 DEGREES OF PROTECTION PROVIDED BY ENCLOSURES (IP CODE) (IEC 60529 EDITION 2.2 CORRIGENDUM 2:2015)
IEC 60584-1:2013 Thermocouples - Part 1: EMF specifications and tolerances
ISO 228-1:2000 Pipe threads where pressure-tight joints are not made on the threads Part 1: Dimensions, tolerances and designation
EN 60730-1:2016 Automatic electrical controls - Part 1: General requirements
EN 257:2010 Mechanical thermostats for gas-burning appliances

View more information
US$124.97
Excluding Tax where applicable

Access your standards online with a subscription

Features

  • Simple online access to standards, technical information and regulations.

  • Critical updates of standards and customisable alerts and notifications.

  • Multi-user online standards collection: secure, flexible and cost effective.