OVERHEAD LINES - REQUIREMENTS AND TESTS FOR STOCKBRIDGE TYPE AEOLIAN VIBRATION DAMPERS

Available format(s)

Hardcopy , PDF

Superseded date

05-13-2020

Language(s)

English

Published date

01-01-1999

Preview

For Harmonized Standards, check the EU site to confirm that the Standard is cited in the Official Journal.

Only cited Standards give presumption of conformance to New Approach Directives/Regulations.

FOREWORD
1 Scope
2 Normative references
3 Definitions
4 General requirements
  4.1 Design
  4.2 Materials
  4.3 Mass, dimensions and tolerances
  4.4 Protection against corrosion
  4.5 Manufacturing appearance and finish
  4.6 Marking
  4.7 Installation instructions
5 Quality assurance
6 Classification of tests
  6.1 Type tests
       6.1.1 General
       6.1.2 Application
  6.2 Sample tests
       6.2.1 General
       6.2.2 Application
       6.2.3 Sampling, acceptance criteria
  6.3 Routine tests
       6.3.1 General
       6.3.2 Application and acceptance criteria
  6.4 Table of tests to be applied
7 Test methods
  7.1 Visual examination
  7.2 Verification of dimensions, materials and mass
  7.3 Corrosion protection tests
       7.3.1 Hot dip galvanized components (other than
               messenger cable wires)
       7.3.2 Ferrous components protected from corrosion
               by methods other than hot dip galvanizing
       7.3.3 Hot dip galvanized messenger cable wires
  7.4 Non-destructive tests
  7.5 Clamp slip test
  7.6 Breakaway bolt test
  7.7 Clamp bolt tightening test
  7.8 Attachment of weights to messenger cable
  7.9 Attachment of clamp to messenger cable test
  7.10 Corona and radio interference voltage (RIV) tests
  7.11 Damper performance tests
       7.11.1 Performance test variants
       7.11.2 Damper characteristic test
       7.11.3 Damper effectiveness evaluation
               7.11.3.1 Methods of evaluation
               7.11.3.2 Laboratory test
               7.11.3.3 Field test
               7.11.3.4 Analytical method
  7.12 Damper fatigue test
       7.12.1 Test methods
       7.12.2 Swept frequency method
       7.12.3 Resonant frequency method
       7.12.4 Acceptance criteria
Annex A (normative) Minimum technical details to be agreed
                       between purchaser and supplier
Annex B (informative) Examples of graphs relevant to damper
                       characteristic test
Annex C (normative) Wind power input curve
Annex ZA (normative) Normative references to international
                       publications with their corresponding
                       European publications
Bibliography

Applicable to Stockbridge type aeolian vibration dampers meant for single conductors or earth wires or conductor bundles where dampers are directly attached to each subconductor.

DevelopmentNote
For CENELEC adoptions of IEC publications, please check www.iec.ch to be sure that you have any corrigenda that may apply. (01/2017)
DocumentType
Standard
Pages
60
PublisherName
National Standards Authority of Ireland
Status
Superseded
SupersededBy

Standards Relationship
NF EN 61897 : 2001 Identical
BS EN 61897:1999 Identical
SN EN 61897 : 1998 Identical
EN 61897:1998 Identical
IEC 61897:1998 Identical
UNE-EN 61897:2000 Identical
DIN EN 61897 : 1999 Identical
NBN EN 61897 : 1999 Identical

ISO 9004-1:1994 Quality management and quality system elements Part 1: Guidelines
IEEE 563 : 1978 CONDUCTOR SELF-DAMPING MEASUREMENTS, GUIDE ON
ISO 3951:1989 Sampling procedures and charts for inspection by variables for percent nonconforming
ISO 1461:2009 Hot dip galvanized coatings on fabricated iron and steel articles — Specifications and test methods
IEC 60888:1987 Zinc-coated steel wires for stranded conductors
ISO 2859-2:1985 Sampling procedures for inspection by attributes — Part 2: Sampling plans indexed by limiting quality (LQ) for isolated lot inspection
IEC 60050-466:1990 International Electrotechnical Vocabulary (IEV) - Part 466: Overhead lines
ISO 9001:2015 Quality management systems — Requirements
ISO 9003:1994 Quality systems Model for quality assurance in final inspection and test
IEEE 664:1993 IEEE Guide for Laboratory Measurement of the Power Dissipation Characteristics of Aeolian Vibaration<br>
ISO 9000-1:1994 Quality management and quality assurance standards — Part 1: Guidelines for selection and use
EN 61284:1997 Overhead lines - Requirements and tests for fittings

View more information
US$70.16
Excluding Tax where applicable

Access your standards online with a subscription

Features

  • Simple online access to standards, technical information and regulations.

  • Critical updates of standards and customisable alerts and notifications.

  • Multi-user online standards collection: secure, flexible and cost effective.