• There are no items in your cart

I.S. EN IEC 61347-2-14:2018

Superseded
Superseded

A superseded Standard is one, which is fully replaced by another Standard, which is a new edition of the same Standard.

View Superseded by
superseded

A superseded Standard is one, which is fully replaced by another Standard, which is a new edition of the same Standard.

LAMP CONTROLGEAR - PART 2-14: PARTICULAR REQUIREMENTS FOR DC AND/OR AC SUPPLIED ELECTRONIC CONTROLGEAR FOR FLUORESCENT INDUCTION LAMPS
Superseded date

12-31-2021

Published date

05-27-2018

For Harmonized Standards, check the EU site to confirm that the Standard is cited in the Official Journal.

Only cited Standards give presumption of conformance to New Approach Directives/Regulations.

National Foreword
FOREWORD
INTRODUCTION
1 Scope
2 Normative references
3 Terms and definitions
4 General requirements
5 General notes on tests
6 Classification
7 Marking
8 Protection against accidental contact with live parts
9 Terminals
10 Provisions for earthing
11 Moisture resistance and insulation
12 Electric strength
13 Thermal endurance test for windings
14 Fault conditions
15 Protection of associated components
16 Abnormal conditions
17 Construction
18 Creepage distances and clearances
19 Screws, current-carrying parts and connections
20 Resistance to heat, fire and tracking
21 Resistance to corrosion
Annex A (normative) - Test to establish whether a
        conductive part is a live part which
        may cause an electric shock
Annex B (normative) - Particular requirements for thermally
        protected lamp controlgear
Annex C (normative) - Particular requirements for electronic
        lamp controlgear with means of protection
        against overheating
Annex D (normative) - Requirements for carrying out
        the heating tests of thermally protected lamp
        controlgear
Annex E (normative) - Use of constant S other
        than 4500 in t[w] tests
Annex F (normative) - Draught-proof enclosure
Annex G (normative) - Explanation of the derivation of
        the values of pulse voltages
Annex H (normative) - Tests
Annex I (normative) - Additional requirements for built-in
        magnetic ballast with double or reinforced insulation
Annex J (normative) - Particular additional safety requirements
        for DC and/or AC supplied electronic controlgear for
        emergency lighting
Annex K (informative) - Conformity testing during manufacture
Annex L (normative) - Particular additional requirements for
        controlgear providing SELV
Annex M (informative) - Dielectric strength test voltages for
        controlgear intended for the use in impulse
        withstand Category III
Annex N (normative) - Requirements for insulation
        materials used for double or reinforced insulation
Annex O (normative) - Additional requirements for built-in
        electronic controlgear with double or reinforced insulation
Annex P (normative) - Creepage distances and clearances
        and distance through insulation (DTI) for lamp controlgear
        which are protected against pollution by the use
        of coating or potting
Annex Q (informative) - Example for U[p] calculation
Annex R (informative) - Concept of creepage distances and
        clearances
Annex S (informative) - Examples of controlgear insulation
        coordination
Annex T (informative) - Creepage distances and clearances
        for controlgear with a higher degree of availability
        (impulse withstand category III)
Bibliography
Annex ZA (normative) - Normative references to
         international publications with their
         corresponding European publications

Defines particular safety requirements for electronic controlgear for use on AC supplies up to 1000 V at 50 Hz or 60 Hz and/or DC supplies with operating frequencies deviating from the supply frequency, associated with fluorescent induction lamps as specified in IEC 62532 and IEC 62639, for high-frequency operation.

DevelopmentNote
For CENELEC adoptions of IEC publications, please check www.iec.ch to be sure that you have any corrigenda that may apply. (05/2018)
DocumentType
Standard
PublisherName
National Standards Authority of Ireland
Status
Superseded
SupersededBy

Standards Relationship
EN IEC 61347-2-14:2018 Identical

IEC 61547:2009 Equipment for general lighting purposes - EMC immunity requirements
IEC 62639:2012 Fluorescent induction lamps - Performance specification
IEC 61347-1:2015 RLV Lamp controlgear - Part 1: General and safety requirements
EN 60929:2011/A1:2016 AC AND/OR DC-SUPPLIED ELECTRONIC CONTROL GEAR FOR TUBULAR FLUORESCENT LAMPS - PERFORMANCE REQUIREMENTS
IEC 60929:2011+AMD1:2015 CSV AC and/or DC-supplied electronic control gear for tubularfluorescent lamps - Performance requirements
IEC 62532:2011+AMD1:2016 CSV Fluorescent induction lamps - Safety specifications
EN 62532:2011/A1:2017 FLUORESCENT INDUCTION LAMPS - SAFETY SPECIFICATIONS
EN 61347-2-7:2012 Lamp controlgear - Part 2-7: Particular requirements for battery supplied electronic controlgear for emergency lighting (self-contained)
EN 61347-1:2015 Lamp controlgear - Part 1: General and safety requirements
IEC 61347-2-7:2011+AMD1:2017 CSV Lamp controlgear - Part 2-7: Particular requirements for battery supplied electronic controlgear for emergency lighting (self-contained)
IEC 60598-2-22:2014+AMD1:2017 CSV Luminaires - Part 2-22: Particular requirements - Luminaires for emergency lighting
EN 61547:2009 Equipment for general lighting purposes - EMC immunity requirements
EN 62639:2012 Fluorescent induction lamps - Performance specification

View more information
Sorry this product is not available in your region.

Access your standards online with a subscription

Features

  • Simple online access to standards, technical information and regulations.

  • Critical updates of standards and customisable alerts and notifications.

  • Multi-user online standards collection: secure, flexible and cost effective.