• There are no items in your cart

IEC 60287-1-1:2006+AMD1:2014 CSV

Superseded
Superseded

A superseded Standard is one, which is fully replaced by another Standard, which is a new edition of the same Standard.

View Superseded by
superseded

A superseded Standard is one, which is fully replaced by another Standard, which is a new edition of the same Standard.

Electric cables - Calculation of the current rating - Part 1-1:Current rating equations (100 % load factor) and calculation of losses - General
Available format(s)

Hardcopy , PDF , PDF 3 Users , PDF 5 Users , PDF 9 Users

Superseded date

05-22-2023

Language(s)

English - French

Published date

11-13-2014

FOREWORD
INTRODUCTION
1 General
2 Calculation of losses

IEC 60287-1-1:2006+A1:2014 Applicable to the conditions of steady-state operation of cables at all alternating voltages, and direct voltages up to 5 kV, buried directly in the ground, in ducts, troughs or in steel pipes, both with and without partial drying-out of the soil, as well as cables in air. The term "steady state" is intended to mean a continuous constant current (100 % load factor) just sufficient to produce asymptotically the maximum conductor temperature, the surrounding ambient conditions being assumed constant. Provides formulae for current ratings and losses. The formulae given are essentially literal and designedly leave open the selection of certain important parameters. These may be divided into three groups:
- parameters related to construction of a cable (for example, thermal resistivity of insulating material) for which representative values have been selected based on published work;
- parameters related to the surrounding conditions, which may vary widely, the selection of which depends on the country in which the cables are used or are to be used;
- parameters which result from an agreement between manufacturer and user and which involve a margin for security of service (for example, maximum conductor temperature). This consolidated version consists of the second edition (2006) and its amendment 1 (2014). Therefore, no need to order amendment in addition to this publication.

Committee
TC 20
DevelopmentNote
Supersedes IEC 60287 (03/2001) Stability Date: 2019. (11/2014)
DocumentType
Standard
Pages
136
PublisherName
International Electrotechnical Committee
Status
Superseded
SupersededBy
Supersedes

BS IEC 60287-2-1:2015 Electric cables. Calculation of the current rating Thermal resistance. Calculation of thermal resistance
13/30288278 DC : 0 BS IEC 60287-2-3 - ELECTRIC CABLES - CALCULATION OF THE CURRENT RATING - PART 2-3: CABLES INSTALLED IN VENTILATED TUNNELS
BS 7769-3-2(2012) : 2012 ELECTRIC CABLES - CALCULATION OF THE CURRENT RATING - PART 3-2: SECTIONS ON OPERATING CONDITIONS - ECONOMIC OPTIMIZATION OF POWER CABLE SIZE
CEI EN 62271-204 : 2012 HIGH-VOLTAGE SWITCHGEAR AND CONTROLGEAR - PART 204: RIGID GAS-INSULATED TRANSMISSION LINES FOR RATED VOLTAGES ABOVE 52 KV
IEEE 525-2007 IEEE Guide for the Design and Installation of Cable Systems in Substations
IEC 62067:2011 RLV Power cables with extruded insulation and their accessories for rated voltages above 150 kV (<em>U</em><sub>m</sub> = 170 kV) up to 500 kV (<em>U</em><sub>m</sub> = 550 kV) - Test methods and requirements
UNE-EN 62271-204:2012 High-voltage switchgear and controlgear - Part 204: Rigid gas-insulated transmission lines for rated voltage above 52 kV
14/30290103 DC : 0 BS EN 62895 - HIGH VOLTAGE DIRECT CURRENT (HVDC) POWER TRANSMISSION CABLES WITH EXTRUDED INSULATION AND THEIR ACCESSORIES FOR RATED VOLTAGES UP TO 320KV FOR LAND APPLICATIONS - TEST METHODS AND REQUIREMENTS
BS IEC 62895:2017 High voltage direct current (HVDC) power transmission. Cables with extruded insulation and their accessories for rated voltages up to 320 kV for land applications. Test methods and requirements
BS IEC 60287-2-3:2017 Electric cables. Calculation of the current rating Thermal resistance. Cables installed in ventilated tunnels
CEI 20-21/3-2 : 2007 ELECTRIC CABLES - CALCULATION OF THE CURRENT RATING - PART 3-2: SECTIONS ON OPERATING CONDITIONS - ECONOMIC OPTIMIZATION OF POWER CABLE SIZE
I.S. HD 632:2016 POWER CABLES WITH EXTRUDED INSULATION AND THEIR ACCESSORIES FOR RATED VOLTAGES ABOVE 36 KV (U[M] = 42 KV) UP TO 150 KV (U[M] = 170 KV)
IEC 60287-2-1 REDLINE : 2ED 2015 ELECTRIC CABLES - CALCULATION OF THE CURRENT RATING - PART 2-1: THERMAL RESISTANCE - CALCULATION OF THERMAL RESISTANCE
IEC 60840:2011 RLV Power cables with extruded insulation and their accessories for rated voltages above 30 kV (<em>U</em><sub>m</sub> = 36 kV) up to 150 kV (<em>U</em><sub>m</sub> = 170 kV) - Test methods and requirements
17/30354643 DC : 0 BS EN 62933-2-1 - ELECTRIC ENERGY STORAGE (ESS) SYSTEMS - PART 2-1: UNIT PARAMETERS AND TESTING METHODS - GENERAL SPECIFICATION
12/30273095 DC : 0 BS IEC 60287-2-1 1994+A2:2006+A3 - ELECTRIC CABLES - CALCULATION OF THE CURRENT RATING - PART 2-1: THERMAL RESISTANCE - CALCULATION OF THERMAL RESISTANCE
BS IEC 60287-1-3:2002 Electric cables. Calculation of the current rating Current rating equations (100 % load factor) and calculation of losses - Current sharing between parallel single-core cables and calculation of circulating current losses
IEC 60287-2-1:2015 RLV Electric cables - Calculation of the current rating - Part 2-1: Thermal resistance - Calculation of thermal resistance
EN IEC 62933-2-1:2018 Electrical energy storage (EES) systems - Part 2-1: Unit parameters and testing methods - General specification
I.S. EN IEC 62933-2-1:2018 ELECTRICAL ENERGY STORAGE (EES) SYSTEMS - PART 2-1: UNIT PARAMETERS AND TESTING METHODS - GENERAL SPECIFICATION
NFC 32 902 : 1998 INSULATED CABLES AND CORDS FOR INSTALLATIONS - POWER CABLE ACCESSORIES INTENDED FOR INDUSTRY, FOR RATED VOLTAGE 0,6/1(1,2) KV - TEST METHODS AND TEST REQUIREMENTS
IEC 60840 REDLINE : 4.0 POWER CABLES WITH EXTRUDED INSULATION AND THEIR ACCESSORIES FOR RATED VOLTAGES ABOVE 30 KV (U[M] = 36 KV) UP TO 150 KV (U[M] = 170 KV) - TEST METHODS AND REQUIREMENTS
IEC 60287-1-3:2002 Electric cables - Calculation of the current rating - Part 1-3: Current rating equations (100 % load factor) and calculation of losses - Current sharing between parallel single-core cables and calculation of circulating current losses
IEC 60287-2-3:2017 Electric cables - Calculation of the current rating - Part 2-3: Thermal resistance - Cables installed in ventilated tunnels
IEC 62067 : 2.0EN+(REDLINE+VERSION) POWER CABLES WITH EXTRUDED INSULATION AND THEIR ACCESSORIES FOR RATED VOLTAGES ABOVE 150 KV (U[M] = 170 KV) UP TO 500 KV (U[M] = 550 KV) - TEST METHODS AND REQUIREMENTS
IEC 60287-2-2:1995 Electric cables - Calculation of the current rating - Part 2: Thermal resistance - Section 2: A method for calculating reduction factors for groups of cables in free air, protected from solar radiation
IEEE 45.8-2016 IEEE Recommended Practice for Electrical Installations on Shipboard--Cable Systems
I.S. EN 62271-204:2011 HIGH-VOLTAGE SWITCHGEAR AND CONTROLGEAR - PART 204: RIGID GAS-INSULATED TRANSMISSION LINES FOR RATED VOLTAGE ABOVE 52 KV (IEC 62271-204:2011 (EQV))
BS 7769-1.2:1994 Electric cables. Calculation of the current rating. Current rating equations (100% load factor) and calculation of losses Sheath eddy current loss factors for two circuits in flat formation
CEI 20-66 : 2010 POWER CABLES WITH EXTRUDED INSULATION AND THEIR ACCESSORIES FOR RATED VOLTAGES ABOVE 36 KV (U[M] = 42 KV) UP TO 150 KV (U[M] = 170 KV)
IEEE 848-2015 IEEE Standard Procedure for the Determination of the Ampacity Derating Factor for Fire-Protected Cable Systems
BS 7454(1991) : 1991 METHOD FOR CALCULATION OF THERMALLY PERMISSIBLE SHORT-CIRCUIT CURRENTS, TAKING INTO ACCOUNT NON-ADIABATIC HEATING EFFECTS
IEC 60183:2015 Guidance for the selection of high-voltage A.C. cable systems
IEC 60287-3-2:2012 Electric cables - Calculation of the current rating - Part 3-2: Sections on operating conditions - Economic optimization of power cable size
IEC 62040-1:2017 EXV UNINTERRUPTIBLE POWER SYSTEMS (UPS) - PART 1: SAFETY REQUIREMENTS
IEC 60364-5-523:1999 Electrical installations of buildings - Part 5: Selection and erection of electrical equipment - Section 523: Current-carrying capacities in wiring systems
IEC 62271-204:2011 High-voltage switchgear and controlgear - Part 204: Rigid gas-insulated transmission lines for rated voltage above 52 kV
EN 62271-204:2011 High-voltage switchgear and controlgear - Part 204: Rigid gas-insulated transmission lines for rated voltage above 52 kV
IEC 60287-1-2:1993 Electric cables - Calculation of the current rating - Part 1: Current rating equations (100 % load factor) and calculations of losses - Section 2: Sheath eddy current loss factors for two circuits in flat formation
BS IEC 60287-3-2:2012 Electric cables. Calculation of the current rating Sections on operating conditions. Economic optimization of power cable size
BS EN 62271-204:2011 High-voltage switchgear and controlgear Rigid gas-insulated transmission lines for rated voltage above 52 kV
IEEE 422-2012 IEEE Guide for the Design of Cable Raceway Systems for Electric Generating Facilities
05/30131315 DC : DRAFT JUN 2005 IEC 60287-3-3 - ELECTRIC CABLES - CALCULATION OF THE CURRENT RATING - PART 3-3: SECTIONS ON OPERATING CONDITIONS - CABLES CROSSING EXTERNAL HEAT SOURCES
IEC 62933-2-1:2017 Electrical energy storage (EES) systems - Part 2-1: Unit parameters and testing methods - General specification

IEC 60028:1925 International standard of resistance for copper
IEC 60228:2004 Conductors of insulated cables
IEC 60502-2:2014 RLV Power cables with extruded insulation and their accessories for rated voltages from 1 kV (<em>U</em><sub>m</sub> = 1,2 kV) up to 30 kV (<em>U</em><sub>m</sub> = 36 kV) – Part 2: Cables for rated voltages from 6 kV (<em>U</em><sub>m</sub> = 7,2 kV) up to 30 kV (<em>U</em><sub>m</sub> = 36 kV)
IEC 60502-1:2004+AMD1:2009 CSV Power cables with extruded insulation and their accessories for rated voltages from 1 kV (<em>U</em><sub>m</sub> = 1,2 kV) up to 30 kV(<em>U</em><sub>m</sub> = 36 kV) - Part 1: Cables for rated voltages of 1 kV (<em>U</em><sub>m</sub> = 1,2 kV) and 3 kV (<em>U</em><sub>m</sub> = 3,6 kV)
IEC 60889:1987 Hard-drawn aluminium wire for overhead line conductors
IEC 60027-3:2002 Letter symbols to be used in electrical technology - Part 3: Logarithmic and related quantities, and their units

View more information
US$389.00
Excluding Tax where applicable

Access your standards online with a subscription

Features

  • Simple online access to standards, technical information and regulations.

  • Critical updates of standards and customisable alerts and notifications.

  • Multi-user online standards collection: secure, flexible and cost effective.