IEC 60432-1:1999+AMD1:2005+AMD2:2011 CSV
Current
The latest, up-to-date edition.
Hardcopy , PDF , PDF 3 Users , PDF 5 Users , PDF 9 Users
English - French
02-10-2012
FOREWORD
1 General
2 Requirements
3 Assessment
Annex A (normative) - Miscellaneous test procedures
Annex B (normative) - Packaging marking symbols
Annex C (normative) - Resistance to torque test procedures
Annex D (normative) - Induced-failure test
Annex E (normative) - Operation-to-failure test
Annex F (normative) - Acceptance numbers for various sample
sizes and AQLs
Annex G (normative) - Acceptance criteria - Continuously
variable results
Annex H (normative) - Induced-failure test - Grouping,
sampling and compliance
Annex J (normative) - Method of measuring mains impedance
Annex K (informative) - Information for luminaire design
IEC 60432-1:1999+A1:2005+A2:2011 specifies the safety and interchangeability requirements of tungsten filament incandescent lamps for general lighting service having:
- rated wattage up to and including 200 W;
- rated voltage of 50 V to 250 V inclusive;
- bulbs of the A, B, C, G, M, P, PS, PAR or R shapes* , or other bulb shapes where the lamps are intended to serve the same purpose as lamps with the foregoing bulb shapes;
- bulbs with all kinds of finishes;
- caps B15d, B22d, E12, E14, E17, E26** , E26d, E26/50x39, E27 or E27/51x39. The technical content is therefore identical to the base edition and its amendments and has been prepared for user convenience. It bears the edition number 2.2. A vertical line in the margin shows where the base publication has been modified by amendments 1 and 2. This consolidated version consists of the second edition (1999), its amendment 1 (2005) and its amendment 2 (2011). Therefore, no need to order amendments in addition to this publication.
Committee |
TC 34/SC 34A
|
DevelopmentNote |
Supersedes IEC 60432 (05/2005) Stability Date: 2025. (09/2017)
|
DocumentType |
Standard
|
Pages |
92
|
PublisherName |
International Electrotechnical Committee
|
Status |
Current
|
Supersedes |
Standards | Relationship |
GOST R IEC 60432-1 : 1999 ERRATA 2005 | Identical |
NF EN 60432-1 : 2001 AMD 2 2013 | Identical |
NEN 10432-1 : 95 AMD 2 97 | Identical |
SANS 60432-1 : 1.02ED 2013 | Identical |
SAC GB 14196.1 : 2002 | Identical |
AS/NZS 60432.1:2007 | Identical |
SN EN 60432-1 : 2000 | Identical |
VDE 0715-1 : 2012 | Identical |
DIN EN 60432-1 : 2012 | Identical |
UNE-EN 60432-1:2001 | Identical |
BS EN 60432-1 : 2000 | Identical |
17/30355026 DC : 0 | BS EN 60081:1998/FPRA6:2015/PRAA:2017 - DOUBLE-CAPPED FLUORESCENT LAMPS - PERFORMANCE SPECIFICATIONS |
BS EN 60630 : 1999 | MAXIMUM LAMP OUTLINERS FOR INCANDESCENT LAMPS |
PREN 12665 : DRAFT 2009 | LIGHT AND LIGHTING - BASIC TERMS AND CRITERIA FOR SPECIFYING LIGHTING REQUIREMENTS |
CSA C22.2 No. 62560 : 2016 | SELF-BALLASTED LED-LAMPS FOR GENERAL LIGHTING SERVICES BY VOLTAGE > 50 V - SAFETY SPECIFICATIONS |
BS EN 60064 : 1996 | TUNGSTEN FILAMENT LAMPS FOR DOMESTIC AND SIMILAR GENERAL LIGHTING PURPOSES - PERFORMANCE REQUIREMENTS |
CSA E432.2 : 1998 : INC : UPD 1 : 1998 : R2012 | SAFETY SPECIFICATIONS FOR INCANDESCENT LAMPS - TUNGSTEN HALOGEN LAMPS FOR DOMESTIC AND SIMILAR GENERAL LIGHTING PURPOSES |
NF EN 62798 : 2014 | INDUSTRIAL ELECTROHEATING EQUIPMENT - TEST METHODS FOR INFRARED EMITTERS |
BS EN 50019:2000 | Electrical apparatus for potentially explosive atmospheres. Increased safety \'e\' |
BS EN 61231 : 2010 | INTERNATIONAL LAMP CODING SYSTEM (ILCOS) |
I.S. EN 62560:2012&A1:2015&A11:2019 | SELF-BALLASTED LED-LAMPS FOR GENERAL LIGHTING SERVICES BY VOLTAGE > 50 V - SAFETY SPECIFICATIONS |
UNE-EN 60968:2015 | Self-ballasted fluorescent lamps for general lighting services - Safety requirements |
DIN EN 12665:2016-09 (Draft) | LIGHT AND LIGHTING - BASIC TERMS AND CRITERIA FOR SPECIFYING LIGHTING REQUIREMENTS |
IEC 60079-7:2015+AMD1:2017 CSV | Explosive atmospheres - Part 7: Equipment protection by increased safety "e" |
EN IEC 60079-7:2015/A1:2018 | EXPLOSIVE ATMOSPHERES - PART 7: EQUIPMENT PROTECTION BY INCREASED SAFETY 'E' (IEC 60079-7:2015/A1:2017) |
IEC 60432-2:1999+AMD1:2005+AMD2:2012 CSV | Incandescent lamps - Safety specifications - Part 2: Tungsten halogen lamps for domestic and similar general lighting purposes |
EN 60968:2015 | Self-ballasted fluorescent lamps for general lighting services - Safety requirements |
EN 60064:1995/A5:2009 | TUNGSTEN FILAMENT LAMPS FOR DOMESTIC AND SIMILAR GENERAL LIGHTING PURPOSES - PERFORMANCE REQUIREMENTS |
EN 62798:2014/AC:2014 | INDUSTRIAL ELECTROHEATING EQUIPMENT - TEST METHODS FOR INFRARED EMITTERS (IEC 62798:2014) |
CSA C22.2 No. 84 : 2005 : R2010 | INCANDESCENT LAMPS |
04/30113660 DC : DRAFT MAY 2004 | IEC 60079-7 - ELECTRICAL APPARATUS FOR EXPLOSIVE GAS ATMOSPHERES - PART 7: INCREASED SAFETY 'E' |
09/30185891 DC : 0 | BS EN 12665 - LIGHT AND LIGHTING - BASIC TERMS AND CRITERIA FOR SPECIFYING LIGHTING REQUIREMENTS |
PD IEC/TR 62471-2:2009 | Photobiological safety of lamps and lamp systems Guidance on manufacturing requirements relating to non-laser optical radiation safety |
CEI 34-119 : 2010 | GUIDE FOR LUMINAIRE DESIGN - INFORMATION FOR A SAFE AND CORRECT OPERATION OF THE LIGHT SOURCES |
BS EN 62560:2012+A11:2019 | Self-ballasted LED-lamps for general lighting services by voltage > 50 V. Safety specifications |
I.S. EN 60630:2000 | MAXIMUM LAMP OUTLINES FOR INCANDESCENT LAMPS |
CSA C22.2 No. 60079-7 : 2016 | EXPLOSIVE ATMOSPHERES - PART 7: EQUIPMENT PROTECTION BY INCREASED SAFETY 'E' |
I.S. EN 60432-2:2004 | INCANDESCENT LAMPS - SAFETY SPECIFICATIONS - PART 2: TUNGSTEN HALOGEN LAMPS FOR DOMESTIC AND SIMILAR GENERAL LIGHTING PURPOSES (IEC 60432-2:1999 (MOD)) |
UNE-EN 62035:2015 | Discharge lamps (excluding fluorescent lamps) - Safety specifications |
CEI EN 60432-3 : 2013 | INCANDESCENT LAMPS - SAFETY SPECIFICATIONS - PART 3: TUNGSTEN-HALOGEN LAMPS (NON-VEHICLE) |
BS EN 60432-3:2013 | Incandescent lamps. Safety specifications Tungsten-halogen lamps (non-vehicle) |
IEC 60598-1:2014+AMD1:2017 CSV | Luminaires - Part 1: General requirements and tests |
I.S. EN 62035:2014 | DISCHARGE LAMPS (EXCLUDING FLUORESCENT LAMPS) - SAFETY SPECIFICATIONS |
IEC TR 62471-2:2009 | Photobiological safety of lamps and lamp systems - Part 2: Guidance on manufacturing requirements relating to non-laser optical radiation safety |
ISA 60079-7 : 2008 | EXPLOSIVE ATMOSPHERES - PART 7: EQUIPMENT PROTECTION BY INCREASED SAFETY "E" |
ANSI C78.20:2003(R2007) | American National Standard for Electric Lamps—A, G, PS, and Similar Shapes with E26 Medium Screw Bases |
BS EN 60968:2015 | Self-ballasted fluorescent lamps for general lighting services. Safety requirements |
09/30204653 DC : 0 | BS EN 61231 - INTERNATIONAL LAMP CODING SYSTEM (ILCOS) |
14/30278882 DC : 0 | BS EN 60079-7 IEC 60079-7 ED. 5.0 - EXPLOSIVE ATMOSPHERES - PART 7: EQUIPMENT PROTECTION BY INCREASED SAFETY 'E' |
BS EN 62798:2014 | Industrial electroheating equipment. Test methods for infrared emitters |
PD IEC TS 61231:1999 | International lamp coding system (ILCOS) |
12/30273415 DC : 0 | BS EN 60968 - SELF-BALLASTED FLUORESCENT LAMPS FOR GENERAL LIGHTING SERVICES - SAFETY REQUIREMENTS |
CEI 76-10 : 2011 | PHOTOBIOLOGICAL SAFETY OF LAMPS AND LAMP SYSTEMS - PART 2: GUIDANCE ON MANUFACTURING REQUIREMENTS RELATING TO NON-LASER OPTICAL RADIATION SAFETY |
BS EN 60598-1:2015 | Luminaires General requirements and tests |
14/30264811 DC : 0 | BS EN 62798 ED 1.0 - INDUSTRIAL ELECTROHEATING EQUIPMENT - TEST METHODS FOR INFRARED EMITTERS |
CAN/CSA-E432-2-98 (R2017) | Safety Specifications for Incandescent Lamps - Part 2: Tungsten Halogen Lamps for Domestic and Similar General Lighting Purposes (adopted IEC 432-2:1994, first edition, including Amendment 1:1996 and Amendment 2:1997, with Canadian deviations) | Prescriptions de sécurité pour lampes à incandescence - Partie 2: Lampes tungstène-halogène pour usage domestique et éclairage général similaire (norme CEI 432-2:1994 adoptée, première édition, avec l\'amendement 1:1996 and l\'amendement 2:1997, avec exigences propres au Canada) |
I.S. EN 60079-7:2015 | EXPLOSIVE ATMOSPHERES - PART 7: EQUIPMENT PROTECTION BY INCREASED SAFETY 'E' |
NF EN 61231 : 2010 AMD 1 2014 | INTERNATIONAL LAMP CODING SYSTEM (ILCOS) |
I.S. EN 60064:1996 | TUNGSTEN FILAMENT LAMPS FOR DOMESTIC AND SIMILAR GENERAL LIGHTING PURPOSES - PERFORMANCE REQUIREMENTS |
I.S. EN 60968:2015 | SELF-BALLASTED FLUORESCENT LAMPS FOR GENERAL LIGHTING SERVICES - SAFETY REQUIREMENTS |
UNI EN 12665 : 2011 | LIGHT AND LIGHTING - BASIC TERMS AND CRITERIA FOR SPECIFYING LIGHTING REQUIREMENTS |
IEC TS 61231:1999 | International lamp coding system (ILCOS) |
09/30207781 DC : 0 | BS EN 62560 - SELF-BALLASTED LED-LAMPS FOR GENERAL LIGHTING SERVICES BY VOLTAGE > 50 V - SAFETY SPECIFICATIONS |
CSA E598.1 : 2002 | LUMINAIRES - PART 1: GENERAL REQUIREMENTS AND TESTS |
BS EN 60079-7 : 2015 | EXPLOSIVE ATMOSPHERES - PART 7: EQUIPMENT PROTECTION BY INCREASED SAFETY 'E' (IEC 60079-7:2015) |
BS EN 60360:1999 | Standard method of measurement of lamp cap temperature rise |
08/30175845 DC : DRAFT JAN 2008 | BS IEC 62471-2 - PHOTO BIOLOGICAL SAFETY OF LAMPS AND LAMP SYSTEMS - PART 2: GUIDANCE ON MANUFACTURING REQUIREMENTS RELATING TO NON-LASER OPTICAL RADIATION SAFETY |
NF EN 60432-2 : 2001 AMD 2 2013 | INCANDESCENT LAMPS - SAFETY SPECIFICATIONS - PART 2: TUNGSTEN HALOGEN LAMPS FOR DOMESTIC AND SIMILAR GENERAL LIGHTING PURPOSES |
CSA E60598.1 : 2016 | LUMINAIRES - PART 1: GENERAL REQUIREMENTS AND TESTS |
I.S. EN 60598-1:2015 | LUMINAIRES - PART 1: GENERAL REQUIREMENTS AND TESTS |
BS EN 60432-2 : 2000 | INCANDESCENT LAMPS - SAFETY SPECIFICATIONS - PART 2: TUNGSTEN HALOGEN LAMPS FOR DOMESTIC AND SIMILAR GENERAL LIGHTING PURPOSES |
I.S. EN 60081:1998 | DOUBLE-CAPPED FLUORESCENT LAMPS - PERFORMANCE SPECIFICATIONS |
UNE-EN 60079-7:2016 | Explosive atmospheres - Part 7: Equipment protection by increased safety "e" |
CSA C22.2 No. 84 : 2005 : R2015 | INCANDESCENT LAMPS |
UNE-EN 60598-1:2015 | Luminaires - Part 1: General requirements and tests |
IEC 62560:2011+AMD1:2015 CSV | Self-ballasted LED-lamps for general lighting services by voltage >50 V - Safety specifications |
I.S. EN 61231:2010 | INTERNATIONAL LAMP CODING SYSTEM (ILCOS) (IEC 61231:2010 (EQV)) |
IEC 62035:2014+AMD1:2016 CSV | Discharge lamps (excluding fluorescent lamps) - Safety specifications |
IEC 60968:2015 | Self-ballasted fluorescent lamps for general lighting services - Safety requirements |
EN 60081:1998/A11:2018 | Double-capped fluorescent lamps - Performance specifications |
IEC 60634:1993 | Heat test source (H.T.S.) lamps for carrying out heating tests on luminaires |
UNE-EN 12665:2012 | Light and lighting - Basic terms and criteria for specifying lighting requirements |
IEC 61231:2010+AMD1:2013 CSV | International lamp coding system (ILCOS) |
BS EN 12665:2011 | Light and lighting. Basic terms and criteria for specifying lighting requirements |
UNE-EN 60064:1998 | TUNGSTEN FILAMENT LAMPS FOR DOMESTIC AND SIMILAR GENERAL LIGHTING PURPOSES. PERFORMANCE REQUIREMENTS. |
IEC 60064:1993+AMD1:2000+AMD2:2002+AMD3:2005 CSV | Tungsten filament lamps for domestic and similar general lighting purposes - Performance requirements |
12/30266672 DC : 0 | BS EN 60598-1 ED 8.0 - LUMINAIRES - PART 1: GENERAL REQUIREMENTS AND TESTS |
UNE-EN 62560:2013 | Self-ballasted LED-lamps for general lighting services by voltage > 50 V - Safety specifications |
UNE-EN 61231:2011 | International lamp coding system (ILCOS) |
I.S. EN 60432-3:2013 | INCANDESCENT LAMPS - SAFETY SPECIFICATIONS - PART 3: TUNGSTENHALOGEN LAMPS (NON-VEHICLE) (IEC 60432-3:2012 (EQV)) |
I.S. EN 62798:2014 | INDUSTRIAL ELECTROHEATING EQUIPMENT - TEST METHODS FOR INFRARED EMITTERS |
CSA E60079.7 : 2003 | ELECTRICAL APPARATUS FOR EXPLOSIVE GAS ATMOSPHERES - PART 7: INCREASED SAFETY "E" |
08/30189882 DC : DRAFT SEP 2008 | BS EN 60630:1999+A6 - MAXIMUM LAMP OUTLINES FOR INCANDESCENT LAMPS |
BIS IS/IEC 60079-7 : 2006 | EXPLOSIVE ATMOSPHERES - PART 7: EQUIPMENT PROTECTION BY INCREASED SAFETY 'E' |
EN 60598-1:2015/A1:2018 | LUMINAIRES - PART 1: GENERAL REQUIREMENTS AND TESTS |
UNE-EN 60432-3:2013 | Incandescent lamps - Safety specifications - Part 3: Tungsten-halogen lamps (non-vehicle) |
CSA C22.2 No. 84 :2005 | INCANDESCENT LAMPS |
BS EN 62035:2014 | Discharge lamps (excluding fluorescent lamps). Safety specifications |
I.S. EN 12665:2011 | LIGHT AND LIGHTING - BASIC TERMS AND CRITERIA FOR SPECIFYING LIGHTING REQUIREMENTS |
I.S. EN 50019:2001 | ELECTRICAL APPARATUS FOR POTENTIALLY EXPLOSIVE ATMOSPHERES - INCREASED SAFETY "E" |
IEC 60630:2005 CSV | Maximum lamp outlines for incandescent lamps |
EN 60630:1998/A7:2015 | MAXIMUM LAMP OUTLINES FOR INCANDESCENT LAMPS (IEC 60630:1994/A7:2014, MODIFIED) |
IEC 60432-3:2012 | Incandescent lamps - Safety specifications - Part 3: Tungsten halogen lamps (non-vehicle) |
EN 60432-2:2000/A2:2012 | INCANDESCENT LAMPS - SAFETY SPECIFICATIONS - PART 2: TUNGSTEN HALOGEN LAMPS FOR DOMESTIC AND SIMILAR GENERAL LIGHTING PURPOSES |
EN 50019:2000/corrigendum Apr. 2003 | ELECTRICAL APPARATUS FOR POTENTIALLY EXPLOSIVE ATMOSPHERES - INCREASED SAFETY "E" |
EN 62035:2014 | Discharge lamps (excluding fluorescent lamps) - Safety specifications |
EN 61231:2010/A1:2013 | INTERNATIONAL LAMP CODING SYSTEM (ILCOS) (IEC 61231:2010/A1:2013) |
EN 60432-3:2013 | Incandescent lamps - Safety specifications - Part 3: Tungsten-halogen lamps (non-vehicle) |
IEC 60061-3:2005 CSV | Lamp caps and holders together with gauges for the control of interchangeability and safety - Part 3: Gauges |
ISO 3951:1989 | Sampling procedures and charts for inspection by variables for percent nonconforming |
IEC TR 62471-2:2009 | Photobiological safety of lamps and lamp systems - Part 2: Guidance on manufacturing requirements relating to non-laser optical radiation safety |
IEC TR 60887:2010 | Glass bulb designation system for lamps |
AS/NZS IEC 61231:2020 | International lamp coding system (ILCOS) |
IEC 60410:1973 | Sampling plans and procedures for inspection by attributes |
IEC 60064:1993+AMD1:2000+AMD2:2002+AMD3:2005 CSV | Tungsten filament lamps for domestic and similar general lighting purposes - Performance requirements |
IEC 60598-1:2014+AMD1:2017 CSV | Luminaires - Part 1: General requirements and tests |
IEC 60061-1:2005 CSV | Lamp caps and holders together with gauges for the control of interchangeability and safety - Part 1: Lamp caps |
IEC 62471:2006 | Photobiological safety of lamps and lamp systems |
IEC 60432-2:1999+AMD1:2005+AMD2:2012 CSV | Incandescent lamps - Safety specifications - Part 2: Tungsten halogen lamps for domestic and similar general lighting purposes |
IEC 60360:1998 | Standard method of measurement of lamp cap temperature rise |
Please Login or Create an Account so you can add users to your Multi user PDF Later.
Important note : All end users must be registered with an Account prior to user licenses being assigned.
Users cannot be edited or removed once added to your Multi user PDF.
Access your standards online with a subscription
Features
-
Simple online access to standards, technical information and regulations.
-
Critical updates of standards and customisable alerts and notifications.
-
Multi-user online standards collection: secure, flexible and cost effective.