• There are no items in your cart

IEC 60432-3:2012

Current
Current

The latest, up-to-date edition.

Incandescent lamps - Safety specifications - Part 3: Tungsten halogen lamps (non-vehicle)
Available format(s)

Hardcopy , PDF , PDF 3 Users , PDF 5 Users , PDF 9 Users

Language(s)

English - French, Spanish, Castilian

Published date

07-04-2012

FOREWORD
1 General
2 Requirements
3 Assessment
Annex A (normative) - Symbols
Annex B (normative) - Method of testing the gas-pressure
Annex C (informative) - Information for luminaire design
Annex D (normative) - Conditions of compliance for design
        tests
Annex E (informative) - Bulb wall temperature measurement
Annex F (normative) - Induced failure test
Bibliography

IEC 60432-3:2012 specifies the safety requirements for single-capped and double-capped tungsten halogen lamps, having rated voltages of up to 250 V, used for the following applications:
- projection (including cinematograph and still projection),
- photographic (including studio),
- floodlighting,
- special purpose,
- general purpose,
- stage lighting.
This second edition of IEC 60432-3 cancels and replaces the first edition published in 2002, Amendment 1 (2005) and Amendment 2 (2008). The main changes with respect to the previous edition are as follows:
- adapting the cold fill pressure requirements and tests for self-shielded lamps to the state of the technology,
- introduction of requirements to fully cover photobiological safety according to IEC 62471.

Committee
TC 34/SC 34A
DevelopmentNote
Stability Date: 2025. (09/2017)
DocumentType
Standard
Pages
65
PublisherName
International Electrotechnical Committee
Status
Current
Supersedes
UnderRevision

BS EN 60630 : 1999 MAXIMUM LAMP OUTLINERS FOR INCANDESCENT LAMPS
IEC 60079-7:2015+AMD1:2017 CSV Explosive atmospheres - Part 7: Equipment protection by increased safety "e"
EN IEC 60079-7:2015/A1:2018 EXPLOSIVE ATMOSPHERES - PART 7: EQUIPMENT PROTECTION BY INCREASED SAFETY 'E' (IEC 60079-7:2015/A1:2017)
EN 62838:2016/AC:2017-11 LEDSI LAMPS FOR GENERAL LIGHTING SERVICES WITH SUPPLY VOLTAGES NOT EXCEEDING 50 V A.C. R.M.S. OR 120 V RIPPLE FREE D.C. - SAFETY SPECIFICATIONS
PD IEC/TR 62471-2:2009 Photobiological safety of lamps and lamp systems Guidance on manufacturing requirements relating to non-laser optical radiation safety
CEI 34-119 : 2010 GUIDE FOR LUMINAIRE DESIGN - INFORMATION FOR A SAFE AND CORRECT OPERATION OF THE LIGHT SOURCES
BS EN 60079-7 : 2015 EXPLOSIVE ATMOSPHERES - PART 7: EQUIPMENT PROTECTION BY INCREASED SAFETY 'E' (IEC 60079-7:2015)
BS EN 60357 : 2003 TUNGSTEN HALOGEN LAMPS (NON-VEHICLE) - PERFORMANCE SPECIFICATIONS (IEC 60357:2002, MODIFIED)
I.S. EN 60630:2000 MAXIMUM LAMP OUTLINES FOR INCANDESCENT LAMPS
CSA C22.2 No. 60079-7 : 2016 EXPLOSIVE ATMOSPHERES - PART 7: EQUIPMENT PROTECTION BY INCREASED SAFETY 'E'
IEC 60598-1:2014+AMD1:2017 CSV Luminaires - Part 1: General requirements and tests
IEC TR 62471-2:2009 Photobiological safety of lamps and lamp systems - Part 2: Guidance on manufacturing requirements relating to non-laser optical radiation safety
ANSI C78.1460 : 2004(R2015) American National Standard for Electric Lamps—Single-Ended Tungsten-Halogen Lamps GZ9.5 Base, T6 Bulb, 36.5mm LCL, 76.2mm MOL with Proximity Reflector
14/30278882 DC : 0 BS EN 60079-7 IEC 60079-7 ED. 5.0 - EXPLOSIVE ATMOSPHERES - PART 7: EQUIPMENT PROTECTION BY INCREASED SAFETY 'E'
CEI 76-10 : 2011 PHOTOBIOLOGICAL SAFETY OF LAMPS AND LAMP SYSTEMS - PART 2: GUIDANCE ON MANUFACTURING REQUIREMENTS RELATING TO NON-LASER OPTICAL RADIATION SAFETY
EN 60598-1:2015/A1:2018 LUMINAIRES - PART 1: GENERAL REQUIREMENTS AND TESTS
BS EN 60598-1:2015 Luminaires General requirements and tests
13/30281739 DC : 0 BS EN 62838 - SELF-BALLASTED LED-LAMPS FOR GENERAL LIGHTING SERVICES WITH SUPPLY VOLTAGES NOT EXCEEDING 50 V A.C. R.M.S. OR 120 V RIPPLE FREE D.C. - SAFETY SPECIFICATION
08/30175845 DC : DRAFT JAN 2008 BS IEC 62471-2 - PHOTO BIOLOGICAL SAFETY OF LAMPS AND LAMP SYSTEMS - PART 2: GUIDANCE ON MANUFACTURING REQUIREMENTS RELATING TO NON-LASER OPTICAL RADIATION SAFETY
CSA E60598.1 : 2016 LUMINAIRES - PART 1: GENERAL REQUIREMENTS AND TESTS
15/30333848 DC : 0 BS EN 60357:2003/PRAA:2015 - TUNGSTEN HALOGEN LAMPS (NON-VEHICLE) - PERFORMANCE SPECIFICATIONS
I.S. EN 60598-1:2015 LUMINAIRES - PART 1: GENERAL REQUIREMENTS AND TESTS
UNE-EN 60598-1:2015 Luminaires - Part 1: General requirements and tests
I.S. EN 60357:2003 TUNGSTEN HALOGEN LAMPS (NON-VEHICLE) - PERFORMANCE SPECIFICATIONS
BS EN 62838:2016 LEDsi lamps for general lighting services with supply voltages not exceeding 50 V a.c. r.m.s. or 120 V ripple free d.c. Safety specifications
UNE-EN 62838:2016 LEDsi lamps for general lighting services with supply voltages not exceeding 50 v a.c. r.m.s. or 120 v ripple free D.C. - Safety specifications
12/30266672 DC : 0 BS EN 60598-1 ED 8.0 - LUMINAIRES - PART 1: GENERAL REQUIREMENTS AND TESTS
08/30189882 DC : DRAFT SEP 2008 BS EN 60630:1999+A6 - MAXIMUM LAMP OUTLINES FOR INCANDESCENT LAMPS
I.S. EN 60079-7:2015 EXPLOSIVE ATMOSPHERES - PART 7: EQUIPMENT PROTECTION BY INCREASED SAFETY 'E'
I.S. EN 62838:2016 LEDSI LAMPS FOR GENERAL LIGHTING SERVICES WITH SUPPLY VOLTAGES NOT EXCEEDING 50 V A.C. R.M.S. OR 120 V RIPPLE FREE D.C. - SAFETY SPECIFICATIONS
UNE-EN 60079-7:2016 Explosive atmospheres - Part 7: Equipment protection by increased safety "e"
IEC 60630:2005 CSV Maximum lamp outlines for incandescent lamps
EN 60630:1998/A7:2015 MAXIMUM LAMP OUTLINES FOR INCANDESCENT LAMPS (IEC 60630:1994/A7:2014, MODIFIED)
EN 60357:2003/A11:2016 TUNGSTEN HALOGEN LAMPS (NON-VEHICLE) - PERFORMANCE SPECIFICATIONS

IEC 60432-1:1999+AMD1:2005+AMD2:2011 CSV Incandescent lamps - Safety specifications - Part 1: Tungsten filament lamps for domestic and similar general lighting purposes
IEC 60061-3:2005 CSV Lamp caps and holders together with gauges for the control of interchangeability and safety - Part 3: Gauges
IEC 60682:1980 Standard method of measuring the pinch temperature of quartz-tungsten-halogen lamps
IEC 60838-1:2016+AMD1:2017 CSV Miscellaneous lampholders - Part 1: General requirements and tests
IEC TR 62471-2:2009 Photobiological safety of lamps and lamp systems - Part 2: Guidance on manufacturing requirements relating to non-laser optical radiation safety
IEC 60050-845:1987 International Electrotechnical Vocabulary (IEV) - Part 845: Lighting
IEC 60127-2:2014 Miniature fuses - Part 2: Cartridge fuse-links
IEC 60410:1973 Sampling plans and procedures for inspection by attributes
IEC 60269-3:2010+AMD1:2013 CSV Low-voltage fuses - Part 3: Supplementary requirements for fuses foruse by unskilled persons (fuses mainly for household or similar applications) - Examples of standardized systems of fuses A to F
IEC 60061-4:2005 CSV Lamp caps and holders together with gauges for the control of interchangeability and safety - Part 4: Guidelines and general information
IEC 60598-1:2014+AMD1:2017 CSV Luminaires - Part 1: General requirements and tests
IEC 60061-1:2005 CSV Lamp caps and holders together with gauges for the control of interchangeability and safety - Part 1: Lamp caps
IEC 62471:2006 Photobiological safety of lamps and lamp systems
AS/NZS 62838:2020 LEDsi lamps for general lighting services with supply voltages not exceeding 50 V a.c. r.m.s. or 120 V ripple free d.c. - Safety specifications (IEC 62838:2015 (ED.1.0)/COR1:2017, MOD)
IEC 60432-2:1999+AMD1:2005+AMD2:2012 CSV Incandescent lamps - Safety specifications - Part 2: Tungsten halogen lamps for domestic and similar general lighting purposes
IEC 60335-2-56:2002+AMD1:2008+AMD2:2014 CSV Household and similar electrical appliances - Safety - Part 2-56:Particular requirements for projectors and similar appliances

View more information
US$273.00
Excluding Tax where applicable

Access your standards online with a subscription

Features

  • Simple online access to standards, technical information and regulations.

  • Critical updates of standards and customisable alerts and notifications.

  • Multi-user online standards collection: secure, flexible and cost effective.