IEC 60603-7-3:2010
Current
The latest, up-to-date edition.
Connectors for electronic equipment - Part 7-3: Detail specification for 8-way, shielded, free and fixed connectors, for data transmission with frequencies up to 100 MHz
Hardcopy , PDF , PDF 3 Users , PDF 5 Users , PDF 9 Users
English - French
04-26-2010
FOREWORD
INTRODUCTION
1 General
2 Terms and definitions
3 Common features and isometric view
4 Cable terminations and internal connections - Fixed and
free connectors
5 Gauges
6 Characteristics
7 Tests and test schedule
Bibliography
IEC 60603-7-3:2010 covers 8-way, shielded, free and fixed connectors, references dimensional, mechanical, electrical and environmental characteristics and tests in IEC 60603-7 and IEC 60603-7-1, and specifies electrical transmission requirements for frequencies up to 100 MHz. These connectors are typically used as category 5 connectors in class D cabling systems specified in ISO/IEC 11801. These connectors are intermateable and interoperable with other IEC 60603-7 series connectors as defined in Clause 2 of IEC 60603-7. These connectors are backward compatible with other IEC 60603-7 series connectors.
Committee |
TC 48/SC 48B
|
DevelopmentNote |
Supersedes IEC PAS 60603-7-3. (02/2008) Stability Date: 2017. (10/2012)
|
DocumentType |
Standard
|
Pages |
25
|
PublisherName |
International Electrotechnical Committee
|
Status |
Current
|
Supersedes |
Standards | Relationship |
NBN EN 60603-7-3 : DEC 2010 | Identical |
NEN EN IEC 60603-7-3 : 2010 | Identical |
DIN EN 60603-7-3 : 2011 | Identical |
VDE 0687-603-7-3 : 2011 | Identical |
CEI EN 60603-7-3 : 2011 | Identical |
NF EN 60603-7-3 : DEC 2010 | Identical |
PN EN 60603-7-3 : NOV 2010 | Identical |
UNE-EN 60603-7-3:2010 | Identical |
EN 60603-7-3:2010 | Identical |
BS EN 60603-7-3:2010 | Identical |
I.S. EN 60603-7-3:2010 | Identical |
13/30279981 DC : 0 | BS EN 50599 - BALANCED COMMUNICATION CABLING IN ACCORDANCE WITH EN 50173-4 SCREENED STRAIGHT PATCH CORDS AND STRAIGHT WORK AREA CORDS FOR CLASS D APPLICATIONS - DETAIL SPECIFICATION |
BS ISO/IEC 11801-1:2017 | Information technology. Generic cabling for customer premises General requirements |
BS EN 61076-3-115:2010 | Connectors for electronic equipment. Product requirements Rectangular connectors. Detail specification for protective housings for use with 8-way shielded and unshielded connectors for frequencies up to 600 MHz for industrial environments incorporating the IEC 60603-7 series interface. Variant 12 related to IEC 61076-3-106. Push-pull type |
CEI EN 61076-3-116 : 2010 | CONNECTORS FOR ELECTRONIC EQUIPMENT - PRODUCT REQUIREMENTS - PART 3-116: RECTANGULAR CONNECTORS - PROTECTIVE HOUSINGS FOR USE WITH 8- WAY SHIELDED AND UNSHIELDED CONNECTORS FOR FREQUENCIES UP TO 600 MHZ FOR INDUSTRIAL ENVIRONMENTS INCORPORATING THE IEC 60603-7 SERIES INTERFACE - VARIANT 13 RELATED TO IEC 61076-3-106 - LOCKING LEVER |
BS EN 50599:2014 | Generic cabling systems. Specification for the testing of balanced communication cabling in accordance with EN 50173-4. Screened straight patch cords and straight work area cords for class D applications. Detail specification |
NF EN 61076-3-114 : 2010 | CONNECTORS FOR ELECTRONIC EQUIPMENT - PRODUCT REQUIREMENTS - PART 3-114: RECTANGULAR CONNECTORS - DETAIL SPECIFICATION FOR PROTECTIVE HOUSINGS FOR USE WITH 8-WAY SHIELDED AND UNSHIELDED CONNECTORS FOR FREQUENCIES UP TO 600 MHZ FOR INDUSTRIAL ENVIRONMENTS INCORPORATING THE IEC 60603-7 SERIES INTERFACE - VARIANT 11 RELATED TO IEC 61076-3-106 - BAYONET COUPLING TYPE |
CSA ISO/IEC 15018 : 2005 : R2010 | INFORMATION TECHNOLOGY - GENERIC CABLING FOR HOMES |
CSA ISO/IEC 15018:2005 | INFORMATION TECHNOLOGY - GENERIC CABLING FOR HOMES |
CSA ISO/IEC 15018 : 2005 : INC : AMD 1 : 2010 : R201000 | INFORMATION TECHNOLOGY - GENERIC CABLING FOR HOMES |
I.S. EN 61935-2-20:2009 | TESTING OF BALANCED COMMUNICATION CABLING IN ACCORDANCE WITH SERIES EN 50173 - PART 2-20: PATCH CORDS AND WORK AREA CORDS - BLANK DETAIL SPECIFICATION FOR CLASS D APPLICATIONS |
I.S. EN 61076-3-116:2008 | CONNECTORS FOR ELECTRONIC EQUIPMENT - PRODUCT REQUIREMENTS - PART 3-116: RECTANGULAR CONNECTORS - DETAIL SPECIFICATION FOR PROTECTIVE HOUSINGS FOR USE WITH 8-WAY SHIELDED AND UNSHIELDED CONNECTORS FOR FREQUENCIES UP TO 600 MHZ FOR INDUSTRIAL ENVIRONMENTS INCORPORATING THE IEC 60603-7 SERIES INTERFACE - VARIANT 13 RELATED TO IEC 61076-3-106 - LOCKING LEVER |
I.S. EN 61784-5-2:2013 | INDUSTRIAL COMMUNICATION NETWORKS - PROFILES - PART 5-2: INSTALLATION OF FIELDBUSES - INSTALLATION PROFILES FOR CPF 2 |
NF EN 60512-26-100 : 2009 AMD 1 2011 | CONNECTORS FOR ELECTRONIC EQUIPMENT - TESTS AND MEASUREMENTS - PART 26-100: MEASUREMENT SETUP, TEST AND REFERENCE ARRANGEMENTS AND MEASUREMENTS FOR CONNECTORS ACCORDING TO IEC 60603-7 - TESTS 26A TO 26G |
IEC PAS 61076-3-117:2006 | Connectors for electronic equipment - Product requirements - Part 3-117: Rectangular connectors - Protective housings for use with 8-way shielded and unshielded connectors for frequencies up to 600 MHz for industrial environments incorporating IEC 60603-7 - Variant 14 related to IEC 61076-3-106 - Push-pull coupling |
EN 60603-7-81:2016/AC:2017-07 | CONNECTORS FOR ELECTRONIC EQUIPMENT - PART 7-81: DETAIL SPECIFICATION FOR 8-WAY, SHIELDED, FREE AND FIXED CONNECTORS, FOR DATA TRANSMISSIONS WITH FREQUENCIES UP TO 2000 MHZ (IEC 60603-7-81:2015/COR 1:2017) |
EN 61076-3-114 : 2009 | Connectors for electronic equipment - Product requirements - Part 3-114: Rectangular connectors - Detail specification for protective housings for use with 8-way shielded and unshielded connectors for frequencies up to 600 MHz for industrial environments incorporating the IEC 60603-7 series interface - Variant 11 related to IEC 61076-3-106 - Bayonet coupling type |
EN 61076-3-116 : 2008 | CONNECTORS FOR ELECTRONIC EQUIPMENT - PRODUCT REQUIREMENTS - PART 3-116: RECTANGULAR CONNECTORS - DETAIL SPECIFICATION FOR PROTECTIVE HOUSINGS FOR USE WITH 8-WAY SHIELDED AND UNSHIELDED CONNECTORS FOR FREQUENCIES UP TO 600 MHZ FOR INDUSTRIAL ENVIRONMENTS INCORPORATING THE IEC 60603-7 SERIES INTERFACE - VARIANT 13 RELATED TO IEC 61076-3-106 - LOCKING LEVER |
BS EN 60512-26-100 : 2008 | CONNECTORS FOR ELECTRONIC EQUIPMENT - TESTS AND MEASUREMENTS - PART 26-100: MEASUREMENT SETUP, TEST AND REFERENCE ARRANGEMENTS AND MEASUREMENTS FOR CONNECTORS ACCORDING TO IEC 60603-7 - TESTS 26A TO 26G |
CLC/TR 50173-99-3:2012 | Information technology - Generic cabling systems - Part 99-3: Home cabling infrastructures up to 50 m in length to support simultaneous and non simultaneous provision of applications |
CEI EN 50173-1 : 2011 | INFORMATION TECHNOLOGY - GENERIC CABLING SYSTEMS - PART 1: GENERAL REQUIREMENTS |
CSA ISO/IEC 24740 : 2008 : R2013 | INFORMATION TECHNOLOGY - RESPONSIVE LINK (RL) |
I.S. EN 61784-5-12:2012 | INDUSTRIAL COMMUNICATION NETWORKS - PROFILES - PART 5-12: INSTALLATION OF FIELDBUSES - INSTALLATION PROFILES FOR CPF 12 (IEC 61784-5-12:2010) |
BS EN 61076-3-116:2008 | Connectors for electronic equipment. Product requirements Rectangular connectors. Detail specification for protective housings for use with 8-way shielded and unshielded connectors for frequencies up to 600 MHz for industrial environments incorporating the IEC 60603-7 series interface. Variant 13 related to IEC 61076-3-106. Locking lever |
I.S. EN 61076-3-115:2010 | CONNECTORS FOR ELECTRONIC EQUIPMENT - PRODUCT REQUIREMENTS - PART 3-115: RECTANGULAR CONNECTORS - DETAIL SPECIFICATION FOR PROTECTIVE HOUSINGS FOR USE WITH 8-WAY SHIELDED AND UNSHIELDED CONNECTORS FOR FREQUENCIES UP TO 600 MHZ FOR INDUSTRIAL ENVIRONMENTS INCORPORATING THE IEC 60603-7 SERIES INTERFACE - VARIANT 12 RELATED TO IEC 61076-3-106 - PUSH-PULL TYPE |
BS EN 60603-7 : 2009 | CONNECTORS FOR ELECTRONIC EQUIPMENT - PART 7: DETAIL SPECIFICATION FOR 8-WAY, UNSHIELDED, FREE AND FIXED CONNECTORS |
EN 50173-1:2011 | Information technology - Generic cabling systems - Part 1: General requirements |
EN 60603-7:2009/A1:2011 | CONNECTORS FOR ELECTRONIC EQUIPMENT - PART 7: DETAIL SPECIFICATION FOR 8-WAY, UNSHIELDED, FREE AND FIXED CONNECTORS (IEC 60603-7:2008/A1:2011) |
I.S. EN 50173-1:2011 | INFORMATION TECHNOLOGY - GENERIC CABLING SYSTEMS - PART 1: GENERAL REQUIREMENTS |
CEI CLC/TR 50173-99-3 : 2013 | INFORMATION TECHNOLOGY - GENERIC CABLING SYSTEMS - PART 99-3: HOME CABLING INFRASTRUCTURES UP TO 50 M IN LENGTH TO SUPPORT SIMULTANEOUS AND NON SIMULTANEOUS PROVISION OF APPLICATIONS |
BS EN 60603-7-81:2016 | Connectors for electronic equipment Detail specification for 8-way, shielded, free and fixed connectors, for data transmissions with frequencies up to 2 000 MHz |
I.S. EN 61784-5-15:2012 | INDUSTRIAL COMMUNICATION NETWORKS - PROFILES - PART 5-15: INSTALLATION OF FIELDBUSES - INSTALLATION PROFILES FOR CPF 15 |
BS EN 50173-1:2011 | Information technology. Generic cabling systems General requirements |
CEI EN 61935-2-20 : 2011 | TESTING OF BALANCED COMMUNICATION CABLING IN ACCORDANCE WITH SERIES EN 50173 - PART 2-20: PATCH CORDS AND WORK AREA CORDS - BLANK DETAIL SPECIFICATION FOR CLASS D APPLICATIONS |
CEI EN 61076-3-115 : 2012 | CONNECTORS FOR ELECTRONIC EQUIPMENT - PRODUCT REQUIREMENTS - PART 3-115: RECTANGULAR CONNECTORS - DETAIL SPECIFICATION FOR PROTECTIVE HOUSINGS FOR USE WITH 8-WAY SHIELDED AND UNSHIELDED CONNECTORS FOR FREQUENCIES UP TO 600 MHZ FOR INDUSTRIAL ENVIRONMENTS INCORPORATING THE IEC 60603-7 SERIES INTERFACE - VARIANT 12 RELATED TO IEC 61076-3-106 - PUSH-PULL TYPE |
I.S. EN 50599:2014 | GENERIC CABLING SYSTEMS - SPECIFICATION FOR THE TESTING OF BALANCED COMMUNICATION CABLING IN ACCORDANCE WITH EN 50173-4 - SCREENED STRAIGHT PATCH CORDS AND STRAIGHT WORK AREA CORDS FOR CLASS D APPLICATIONS - DETAIL SPECIFICATION |
16/30346304 DC : 0 | BS EN 61162-450 - MARITIME NAVIGATION AND RADIOCOMMUNICATION EQUIPMENT AND SYSTEMS -DIGITAL INTERFACES - PART 450: MULTIPLE TALKERS AND MULTIPLE LISTENERS - ETHERNET INTERCONNECTION |
ANSI INCITS 435 : 2007 | INFORMATION TECHNOLOGY - FIBRE CHANNEL - BASET (FC-BASET) |
ISO/IEC 14165-151:2017 | Information technology Fibre channel Part 151: Fibre Channel BaseT (FC-BaseT) |
I.S. EN 60603-7-81:2016 | CONNECTORS FOR ELECTRONIC EQUIPMENT - PART 7-81: DETAIL SPECIFICATION FOR 8-WAY, SHIELDED, FREE AND FIXED CONNECTORS, FOR DATA TRANSMISSIONS WITH FREQUENCIES UP TO 2000 MHZ |
I.S. EN 61162-450:2011 | MARITIME NAVIGATION AND RADIOCOMMUNICATION EQUIPMENT AND SYSTEMS - DIGITAL INTERFACES - PART 450: MULTIPLE TALKERS AND MULTIPLE LISTENERS - ETHERNET INTERCONNECTION (IEC 61162-450:2011/A1:2016) |
BS EN 61784-5-2:2013 | Industrial communication networks. Profiles Installation of fieldbuses. Installation profiles for CPF 2 |
BS EN 61784-5-15 : 2012 | INDUSTRIAL COMMUNICATION NETWORKS - PROFILES - PART 5-15: INSTALLATION OF FIELDBUSES - INSTALLATION PROFILES FOR CPF 15 |
BS EN 61784-5-12 : 2012 | INDUSTRIAL COMMUNICATION NETWORKS - PROFILES - PART 5-12: INSTALLATION OF FIELDBUSES - INSTALLATION PROFILES FOR CPF 12 |
S.R. CLC/TR 50173-99-3:2012 | INFORMATION TECHNOLOGY - GENERIC CABLING SYSTEMS - PART 99-3: HOME CABLING INFRASTRUCTURES UP TO 50 M IN LENGTH TO SUPPORT SIMULTANEOUS AND NON SIMULTANEOUS PROVISION OF APPLICATIONS |
NF EN 61076-3-116 : 2009 | CONNECTORS FOR ELECTRONIC EQUIPMENT - PRODUCT REQUIREMENTS - PART 3-116: RECTANGULAR CONNECTORS - DETAIL SPECIFICATION FOR PROTECTIVE HOUSINGS FOR USE WITH 8-WAY SHIELDED AND UNSHIELDED CONNECTORS FOR FREQUENCIES UP TO 600 MHZ FOR INDUSTRIAL ENVIRONMENTS INCORPORATING THE IEC 60603-7 SERIES INTERFACE - VARIANT 13 RELATED TO IEC 61076-3-106 - LOCKING LEVER |
ISO/IEC 11801:2002 | Information technology Generic cabling for customer premises |
ISO/IEC 15018:2004 | Information technology Generic cabling for homes |
IEC 61935-2-20:2008 | Testing of balanced communication cabling in accordance with ISO/IEC 11801 - Part 2-20: Patch cords and work area cords - Blank detail specification for class D applications |
IEC 60603-7:2008+AMD1:2011 CSV | Connectors for electronic equipment - Part 7: Detail specification for 8-way, unshielded, free and fixed connectors |
EN 60603-7-82:2016 | CONNECTORS FOR ELECTRONIC EQUIPMENT - PART 7-82: DETAIL SPECIFICATION FOR 8-WAY, 12 CONTACTS, SHIELDED, FREE AND FIXED CONNECTORS, FOR DATA TRANSMISSION WITH FREQUENCIES UP TO 2000 MHZ (IEC 60603-7-82:2016) |
CEI EN 50599 : 2014 | GENERIC CABLING SYSTEMS - SPECIFICATION FOR THE TESTING OF BALANCED COMMUNICATION CABLING IN ACCORDANCE WITH EN 50173-4 - SCREENED STRAIGHT PATCH CORDS AND STRAIGHT WORK AREA CORDS FOR CLASS D APPLICATIONS - DETAIL SPECIFICATION |
BS EN 61076-3-114:2009 | Connectors for electronic equipment. Product requirements Rectangular connectors. Detail specification for.protective housings for use with 8-way shielded and unshielded connectors for frequencies up to 600 MHz for industrial environments incorporating the IEC 60603-7 series interface. Variant 11 related to IEC 61076-3-106. Bayonet coupling type |
PD CLC/TR 50173-99-3:2012 | Information technology. Generic cabling systems Home cabling infrastructures up to 50 m in length to support simultaneous and non simultaneous provision of applications |
16/30325971 DC : 0 | BS ISO/IEC 11801-1 - INFORMATION TECHNOLOGY - GENERIC CABLING FOR CUSTOMER PREMISES - PART 1: GENERAL REQUIREMENTS |
CSA ISO/IEC 24740 : 2008 | INFORMATION TECHNOLOGY - RESPONSIVE LINK (RL) |
I.S. EN 60603-7:2009 | CONNECTORS FOR ELECTRONIC EQUIPMENT - PART 7: DETAIL SPECIFICATION FOR 8-WAY, UNSHIELDED, FREE AND FIXED CONNECTORS (IEC 60603-7:2008) |
I.S. EN 60603-7-82:2016 | CONNECTORS FOR ELECTRONIC EQUIPMENT - PART 7-82: DETAIL SPECIFICATION FOR 8-WAY, 12 CONTACTS, SHIELDED, FREE AND FIXED CONNECTORS, FOR DATA TRANSMISSION WITH FREQUENCIES UP TO 2000 MHZ |
ISO/IEC 24740:2008 | Information technology Responsive Link (RL) |
I.S. EN 60512-26-100:2008 | CONNECTORS FOR ELECTRONIC EQUIPMENT - TESTS AND MEASUREMENTS - PART 26-100: MEASUREMENT SETUP, TEST AND REFERENCE ARRANGEMENTS AND MEASUREMENTS FOR CONNECTORS ACCORDING TO IEC 60603-7 - TESTS 26A TO 26G |
IEC 61076-3-116:2008 | Connectors for electronic equipment - Product requirements - Part 3-116: Rectangular connectors - Detail specification for protective housings for use with 8-way shielded and unshielded connectors for frequencies up to 600 MHz for industrial environments incorporating the IEC 60603-7 series interface - Variant 13 related to IEC 61076-3-106 - Locking lever |
IEC 61076-3-114:2009 | Connectors for electronic equipment - Product requirements - Part 3-114: Rectangular connectors - Detail specification for protective housings for use with 8-way shielded and unshielded connectors for frequencies up to 600 MHz for industrial environments incorporating the IEC 60603-7 series interface - Variant 11 related to IEC 61076-3-106 - Bayonet coupling type |
BS ISO/IEC 14165-151:2017 | Information technology. Fibre channel Fibre Channel BaseT (FC-BaseT) |
IEC 61784-5-12:2010+AMD1:2015 CSV | Industrial communication networks - Profiles - Part 5-12: Installation of fieldbuses - Installation profiles for CPF 12 |
IEC 61784-5-15:2010+AMD1:2015 CSV | Industrial communication networks - Profiles - Part 5-15: Installation of fieldbuses - Installation profiles for CPF 15 |
IEC 61784-5-2:2013 | Industrial communication networks - Profiles - Part 5-2: Installation of fieldbuses - Installation profiles for CPF 2 |
IEC 60512-26-100:2008+AMD1:2011 CSV | Connectors for electronic equipment - Tests and measurements - Part 26-100: Measurement setup, test and reference arrangements and measurements for connectors according to IEC 60603-7 - Tests 26a to 26g |
BS EN 61935-2-20:2009 | Testing of balanced communication cabling in accordance with series EN 50173 Patch cords and work area cords. Blank detail specification for class D applications |
PREN 50599 : DRAFT 2013 | BALANCED COMMUNICATION CABLING IN ACCORDANCE WITH EN 50173-4 SCREENED STRAIGHT PATCH CORDS AND STRAIGHT WORK AREA CORDS FOR CLASS D APPLICATIONS - DETAIL SPECIFICATION |
BS EN 61162-450:2011 | Maritime navigation and radiocommunication equipment and systems. Digital interfaces Multiple talkers and multiple listeners. Ethernet interconnection |
CSA ISO/IEC 15018 : 2005 : INC : AMD 1 : 2010 : R2015 | INFORMATION TECHNOLOGY - GENERIC CABLING FOR HOMES |
BS EN 60603-7-82:2016 | Connectors for electronic equipment Detail specification for 8-way, 12 contacts, shielded, free and fixed connectors, for data transmission with frequencies up to 2 000 MHz |
ISO/IEC 11801-1:2017 | Information technology — Generic cabling for customer premises — Part 1: General requirements |
NF EN 61076-3-115 : 2011 | CONNECTORS FOR ELECTRONIC EQUIPMENT - PRODUCT REQUIREMENTS - PART 3-115: RECTANGULAR CONNECTORS - DETAIL SPECIFICATION PROTECTIVE HOUSINGS FOR USE WITH 8-WAY SHIELDED AND UNSHIELDED CONNECTORS FOR FREQUENCIES UP TO 600 MHZ FOR INDUSTRIAL ENVIRONMENTS INCORPORATING THE IEC 60603-7 SERIES INTERFACE - VARIANT 12 RELATED TO IEC 61076-3-106 - PUSH-PULL TYPE |
CEI EN 61784-5-2 : 2014 | INDUSTRIAL COMMUNICATION NETWORKS - PROFILES - PART 5-2: INSTALLATION OF FIELDBUSES - INSTALLATION PROFILES FOR CPF 2 |
I.S. EN 61076-3-114:2009 | CONNECTORS FOR ELECTRONIC EQUIPMENT - PRODUCT REQUIREMENTS - PART 3-114: RECTANGULAR CONNECTORS - DETAIL SPECIFICATION FOR PROTECTIVE HOUSINGS FOR USE WITH 8-WAY SHIELDED AND UNSHIELDED CONNECTORS FOR FREQUENCIES UP TO 600 MHZ FOR INDUSTRIAL ENVIRONMENTS INCORPORATING THE IEC 60603-7 SERIES INTERFACE - VARIANT 11 RELATED TO IEC 61076-3-106 - BAYONET COUPLING TYPE |
EN 61784-5-15:2012/A1:2015 | INDUSTRIAL COMMUNICATION NETWORKS - PROFILES - PART 5-15: INSTALLATION OF FIELDBUSES - INSTALLATION PROFILES FOR CPF 15 (IEC 61784-5-15:2010/A1:2015) |
EN 60512-26-100:2008/A1:2011 | CONNECTORS FOR ELECTRONIC EQUIPMENT - TESTS AND MEASUREMENTS - PART 26-100: MEASUREMENT SETUP, TEST AND REFERENCE ARRANGEMENTS AND MEASUREMENTS FOR CONNECTORS ACCORDING TO IEC 60603-7 - TESTS 26A TO 26G |
IEC 60603-7-82:2016 | Connectors for electronic equipment - Part 7-82: Detail specification for 8-way, 12 contacts, shielded, free and fixed connectors, for data transmission with frequencies up to 2 000 MHz |
IEC 61076-3-115:2009 | Connectors for electronic equipment - Product requirements - Part 3-115: Rectangular connectors - Detail specification for protective housings for use with 8-way shielded and unshielded connectors for frequencies up to 600 MHz for industrial environments incorporating the IEC 60603-7 series interface - Variant 12 related to IEC 61076-3-106 - Push-pull type |
EN 61784-5-12:2012/A1:2015 | INDUSTRIAL COMMUNICATION NETWORKS - PROFILES - PART 5-12: INSTALLATION OF FIELDBUSES - INSTALLATION PROFILES FOR CPF 12 (IEC 61784-5-12:2010/A1:2015) |
EN 61076-3-115:2010 | Connectors for electronic equipment - Product requirements - Part 3-115: Rectangular connectors - Detail specification for protective housings for use with 8-way shielded and unshielded connectors for frequencies up to 600 MHz for industrial environments incorporating the IEC 60603-7 series interface - Variant 12 related to IEC 61076-3-106 - Push-pull type |
EN 61784-5-2:2013 | Industrial communication networks - Profiles - Part 5-2: Installation of fieldbuses - Installation profiles for CPF 2 |
EN 60603-7-82 : 2016 | CONNECTORS FOR ELECTRONIC EQUIPMENT - PART 7-82: DETAIL SPECIFICATION FOR 8-WAY, 12 CONTACTS, SHIELDED, FREE AND FIXED CONNECTORS, FOR DATA TRANSMISSION WITH FREQUENCIES UP TO 2000 MHZ (IEC 60603-7-82:2016) |
EN 50599:2014 | Generic cabling systems - Specification for the testing of balanced communication cabling in accordance with EN 50173-4 - Screened straight patch cords and straight work area cords for class D applications - Detail specification |
EN 61935-2-20:2009 | Testing of balanced communication cabling in accordance with series EN 50173 - Part 2-20: Patch cords and work area cords - Blank detail specification for class D applications |
EN 61162-450:2011/A1:2016 | MARITIME NAVIGATION AND RADIOCOMMUNICATION EQUIPMENT AND SYSTEMS - DIGITAL INTERFACES - PART 450: MULTIPLE TALKERS AND MULTIPLE LISTENERS - ETHERNET INTERCONNECTION |
IEC 60603-7-1:2011 | Connectors for electronic equipment - Part 7-1: Detail specification for 8-way, shielded, free and fixed connectors |
IEC 62153-4-12:2009 | Metallic communication cable test methods - Part 4-12: Electromagnetic compatibility (EMC) - Coupling attenuation or screening attenuation of connecting hardware - Absorbing clamp method |
ISO/IEC 11801:2002 | Information technology Generic cabling for customer premises |
IEC 60512-27-100:2011 | Connectors for electronic equipment - Tests and measurements - Part 27-100: Signal integrity tests up to 500 MHz on 60603-7 series connectors - Tests 27a to 27g |
IEC 60512-26-100:2008+AMD1:2011 CSV | Connectors for electronic equipment - Tests and measurements - Part 26-100: Measurement setup, test and reference arrangements and measurements for connectors according to IEC 60603-7 - Tests 26a to 26g |
IEC 60603-7:2008+AMD1:2011 CSV | Connectors for electronic equipment - Part 7: Detail specification for 8-way, unshielded, free and fixed connectors |
IEC 60512-1-100:2012 | Connectors for electronic equipment - Tests and measurements - Part 1-100: General - Applicable publications |
IEC 60512-2-1:2002 | Connectors for electronic equipment - Tests and measurements - Part 2-1: Electrical continuity and contact resistance tests - Test 2a: Contact resistance - Millivolt level method |
Please Login or Create an Account so you can add users to your Multi user PDF Later.
Important note : All end users must be registered with an Account prior to user licenses being assigned.
Users cannot be edited or removed once added to your Multi user PDF.
Access your standards online with a subscription
Features
-
Simple online access to standards, technical information and regulations.
-
Critical updates of standards and customisable alerts and notifications.
-
Multi-user online standards collection: secure, flexible and cost effective.