Common test methods for insulating and sheathing materials of electric cables - Part 1: Methods for general application - Section Four: Tests at low temperature
Available format(s)

Hardcopy , PDF , PDF 3 Users , PDF 5 Users , PDF 9 Users

Superseded date

03-13-2012

Published date

07-30-1985

FOREWORD
PREFACE
Clause
1 Scope
2 Test values
3 Applicability
4 Type tests and other tests
5 Pre-conditioning
6 Test temperature
7 Median value
8 Tests at low temperature
    8.1 Bending test at low temperature for insulations
    8.2 Bending test at low temperature for sheaths
    8.3 Elongation test at low temperature for
         insulations
    8.4 Elongation test at low temperature for sheaths
    8.5 Impact test at low temperature for PVC
         insulations and sheaths
FIGURES
APPENDIX A - Corresponding clauses and sub-clauses in
             IEC Publications 538 and 540 and IEC
             Publication 811

Gives the methods for tests at low temperature which apply to PVCand PV compounds.The contents of the corrigendum of May 1986 have been included inthis copy.

DevelopmentNote
Also numbered as BS EN 60811-1.4 (08/2002) Supersedes IEC 60538 AND IEC 60540 (07/2004)
DocumentType
Standard
Pages
36
PublisherName
International Electrotechnical Committee
Status
Superseded
SupersededBy
Supersedes

NF EN 50290-2-21 : 2002 AMD 1 2008 COMMUNICATION CABLES - PART 2-21: COMMON DESIGN RULES AND CONSTRUCTION - PVC INSULATION COMPOUNDS
CEI 18-49 : 2013 ELECTRICAL INSTALLATIONS IN SHIPS - PART 350: GENERAL CONSTRUCTION AND TEST METHODS OF POWER, CONTROL AND INSTRUMENTATION CABLES FOR SHIPBOARD AND OFFSHORE APPLICATIONS
UNE-EN 50525-2-72:2012 Electric cables - Low voltage energy cables of rated voltages up to and including 450/750 V (Uo/U) -- Part 2-72: Cables for general applications - Flat divisible cables (cords) with thermoplastic PVC insulation
09/30214042 DC : 0 BS EN 60794-2-10 - OPTICAL FIBRE CABLES - PART 2-10: INDOOR OPTICAL FIBRE CABLES - FAMILY SPECIFICATION FOR SIMPLEX AND DUPLEX CABLES
IEC 60227-3:1993+AMD1:1997 CSV Polyvinyl chloride insulated cables of rated voltages up to and including 450/750 V - Part 3: Non-sheathed cables for fixed wiring
BS EN 50382-2 : 2008 RAILWAY APPLICATIONS - RAILWAY ROLLING STOCK HIGH TEMPERATURE POWER CABLES HAVING SPECIAL FIRE PERFORMANCE - PART 2: SINGLE CORE SILICONE RUBBER INSULATED CABLES FOR 120 DEGREES C OR 150 DEGREES C
BS EN 50525-2-12:2011 Electric cables. Low voltage energy cables of rated voltages up to and including 450/750 V (U0/U) Cables for general applications. Cables with thermoplastic PVC insulation for extensible leads
BS EN 50525-3-41:2011 Electric cables. Low voltage energy cables of rated voltages up to and including 450/750 V (U0/U) Cables with special fire performance. Single core non-sheathed cables with halogen-free crosslinked insulation, and low emission of smoke
PREN 50525-2-83 : DRAFT 2008 ELECTRIC CABLES - LOW VOLTAGE ENERGY CABLES OF RATED VOLTAGES UP TO AND INCLUDING 450/750 V - PART 2-83: CABLES FOR GENERAL APPLICATIONS - MULTICORE CABLES WITH CROSSLINKED SILICONE RUBBER INSULATION
CEI EN 50525-2-51 : 2012 ELECTRIC CABLES - LOW VOLTAGE ENERGY CABLES OF RATED VOLTAGES UP TO AND INCLUDING 450/750 V (U[0]/U) - PART 2-51: CABLES FOR GENERAL APPLICATIONS - OIL RESISTANT CONTROL CABLES WITH THERMOPLASTIC PVC INSULATION
UNE-EN 50525-3-11:2012 Electric cables - Low voltage energy cables of rated voltages up to and including 450/750 V (Uo/U) - Part 3-11: Cables with special fire performance - Flexible cables with halogen-free thermoplastic insulation, and low emission of smoke
07/30164222 DC : 0 BS EN 60794-2-20 - OPTICAL FIBRE CABLES - PART 2-20: INDOOR OPTICAL FIBRE CABLES - FAMILY SPECIFICATION FOR MULTI-FIBRE OPTICAL DISTRIBUTION CABLES
BS EN 50363-0:2011 Insulating, sheathing and covering materials for low-voltage energy cables General introduction
CEI EN 50305 : 2003 RAILWAY APPLICATIONS - RAILWAY ROLLING STOCK CABLES HAVING SPECIAL FIRE PERFORMANCE - TEST METHODS
EN 50290-2-27 : 2002 COR 2010 COMMUNICATION CABLES - PART 2-27: COMMON DESIGN RULES AND CONSTRUCTION - HALOGEN FREE FLAME RETARDANT THERMOPLASTIC SHEATHING COMPOUNDS
08/30188796 DC : 0 BS EN 50525-2-41 - ELECTRIC CABLES - LOW VOLTAGE ENERGY CABLES OF RATED VOLTAGES UP TO AND INCLUDING 450/750 V - PART 2-41: CABLES FOR GENERAL APPLICATIONS - SINGLE CORE CABLES WITH CROSSLINKED SILICONE RUBBER INSULATION
I.S. EN 50363-4-1:2005 INSULATING, SHEATHING AND COVERING MATERIALS FOR LOW VOLTAGE ENERGY CABLES - PART 4-1: PVC SHEATHING COMPOUNDS
BS EN 50363-2-2:2005 Insulating, sheathing and covering materials for low voltage energy cables Cross-linked elastomeric covering compounds
07/30143930 DC : 0 BS IEC 60794-2-50 - OPTICAL FIBRE CABLES - PART 2-50: INDOOR OPTICAL FIBRE CABLES - FAMILY SPECIFICATION FOR SIMPLEX AND DUPLEX CABLES FOR USE IN TERMINATED CABLE ASSEMBLIES
BS EN 50363-9-1:2005 Insulating, sheathing and covering materials for low-voltage energy cables Miscellaneous insulating compounds. Cross-linked polyvinyl chloride (XLPVC)
BS EN 50525-2-31:2011 Electric cables. Low voltage energy cables of rated voltages up to and including 450/750 V (U0/U) Cables for general applications. Single core non-sheathed cables with thermoplastic PVC insulation
CEI EN 50525-2-12 : 2012 ELECTRIC CABLES - LOW VOLTAGE ENERGY CABLES OF RATED VOLTAGES UP TO AND INCLUDING 450/750 V (U[0]/U) - PART 2-12: CABLES FOR GENERAL APPLICATIONS - CABLES WITH THERMOPLASTIC PVC INSULATION FOR EXTENSIBLE LEADS
BS EN 50264-2-2:2008 Railway applications. Railway rolling stock power and control cables having special fire performance Cables with crosslinked elastomeric insulation. Multicore cables
NF EN 61138 : 2008 CABLES FOR PORTABLE EARTHING AND SHORT-CIRCUITING EQUIPMENT
BS 6469-1.2(1992) : 1992 INSULATING AND SHEATHING MATERIALS OF ELECTRIC CABLES - METHODS OF TEST FOR GENERAL APPLICATION - THERMAL AGEING METHODS
09/30196635 DC : 0 BS EN 60092-510 - ELECTRICAL INSTALLATIONS IN SHIPS - SPECIAL FEATURES - HIGH VOLTAGE SHORE CONNECTION SYSTEMS (HVSC-SYSTEMS)
08/30188842 DC : 0 BS EN 50525-3-41 - ELECTRIC CABLES - LOW VOLTAGE ENERGY CABLES OF RATED VOLTAGES UP TO AND INCLUDING 450/750 V - PART 3-41: CABLES WITH SPECIAL FIRE PERFORMANCE - SINGLE CORE NON-SHEATHED CABLES WITH HALOGEN-FREE CROSS LINKED INSULATION, AND LOW EMISSION OF SMOKE
CSA E60335.2.14 : 2005 : R2013 Household and similar electrical appliances – Safety – Part 2-14: Particular requirements for kitchen machines
PREN 50525-2-42 : DRAFT 2008 ELECTRIC CABLES - LOW VOLTAGE ENERGY CABLES OF RATED VOLTAGES UP TO AND INCLUDING 450/750 V - PART 2-42: CABLES FOR GENERAL APPLICATIONS - SINGLE CORE NON-SHEATHED CABLES WITH CROSSLINKED EVA INSULATION
CEI EN 50525-2-41 : 2012 ELECTRIC CABLES - LOW VOLTAGE ENERGY CABLES OF RATED VOLTAGES UP TO AND INCLUDING 450/750 V (U[0]/U) - PART 2-41: CABLES FOR GENERAL APPLICATIONS - SINGLE CORE CABLES WITH CROSSLINKED SILICONE RUBBER INSULATION
I.S. EN 50363-10-2:2005 INSULATING, SHEATHING AND COVERING MATERIALS FOR LOW VOLTAGE ENERGY CABLES - PART 10-2: MISCELLANEOUS SHEATHING COMPOUNDS - THERMOPLASTIC POLYURETHANE
I.S. EN 61138:2008 CABLES FOR PORTABLE EARTHING AND SHORT-CIRCUITING EQUIPMENT
I.S. EN 50363-0:2011 INSULATING, SHEATHING AND COVERING MATERIALS FOR LOW-VOLTAGE ENERGY CABLES - PART 0: GENERAL INTRODUCTION
BS EN 50290-2-21 : 2002 COMMUNICATION CABLES - PART 2-21: COMMON DESIGN RULES AND CONSTRUCTION - PVC INSULATION COMPOUNDS
UNE-EN 60811-505:2012 Electric and optical fibre cables - Test methods for non-metallic materials - Part 505: Mechanical tests - Elongation at low temperature for insulations and sheaths
I.S. EN 50264-3-1:2008 RAILWAY APPLICATIONS - RAILWAY ROLLING STOCK POWER AND CONTROL CABLES HAVING SPECIAL FIRE PERFORMANCE - PART 3-1: CABLES WITH CROSSLINKED ELASTOMERIC INSULATION WITH REDUCED DIMENSIONS - SINGLE CORE CABLES
CEI EN 50525-2-72 : 2012 ELECTRIC CABLES - LOW VOLTAGE ENERGY CABLES OF RATED VOLTAGES UP TO AND INCLUDING 450/750 V (U[0]/U) - PART 2-72: CABLES FOR GENERAL APPLICATIONS - FLAT DIVISIBLE CABLES (CORDS) WITH THERMOPLASTIC PVC INSULATION
I.S. EN 50264-2-1:2008 RAILWAY APPLICATIONS - RAILWAY ROLLING STOCK POWER AND CONTROL CABLES HAVING SPECIAL FIRE PERFORMANCE - PART 2-1: CABLES WITH CROSSLINKED ELASTOMERIC INSULATION - SINGLE CORE CABLES
I.S. EN 50363-7:2005 INSULATING, SHEATHING AND COVERING MATERIALS FOR LOW VOLTAGE ENERGY CABLES - PART 7: HALOGEN-FREE, THERMOPLASTIC INSULATING COMPOUNDS
I.S. EN 50290-2-26:2002 COMMUNICATION CABLES - PART 2-26: COMMON DESIGN RULES AND CONSTRUCTION - HALOGEN FREE FLAME RETARDANT INSULATION COMPOUNDS
CEI EN 50525-3-11 : 2012 ELECTRIC CABLES - LOW VOLTAGE ENERGY CABLES OF RATED VOLTAGES UP TO AND INCLUDING 450/750 V (U[0]/U) - PART 3-11: CABLES WITH SPECIAL FIRE PERFORMANCE - FLEXIBLE CABLES WITH HALOGEN-FREE THERMOPLASTIC INSULATION, AND LOW EMISSION OF SMOKE
I.S. EN 50363-2-1:2005 INSULATING, SHEATHING AND COVERING MATERIALS FOR LOW VOLTAGE ENERGY CABLES - PART 2-1: CROSS-LINKED ELASTOMERIC SHEATHING COMPOUNDS
OVE/ONORM EN 60794-2-50 : 2009 OPTICAL FIBRE CABLES - PART 2-50: INDOOR CABLES - FAMILY SPECIFICATION FOR SIMPLEX AND DUPLEX CABLES FOR USE IN TERMINATED CABLE ASSEMBLIES
IEC 61230:2008 Live working - Portable equipment for earthing or earthing and short-circuiting
EN 50290-2-26 : 2002 AMD 1 2007 COMMUNICATION CABLES - PART 2-26: COMMON DESIGN RULES AND CONSTRUCTION - HALOGEN FREE FLAME RETARDANT INSULATION COMPOUNDS
EN 50363-2-1 : 2005 AMD 1 2011 INSULATING, SHEATHING AND COVERING MATERIALS FOR LOW VOLTAGE ENERGY CABLES - PART 2-1: CROSS-LINKED ELASTOMERIC SHEATHING COMPOUNDS
IEC 62067:2011 RLV Power cables with extruded insulation and their accessories for rated voltages above 150 kV (<em>U</em><sub>m</sub> = 170 kV) up to 500 kV (<em>U</em><sub>m</sub> = 550 kV) - Test methods and requirements
EN 50363-8 : 2005 AMD 1 2011 INSULATING, SHEATHING AND COVERING MATERIALS FOR LOW VOLTAGE ENERGY CABLES - PART 8: HALOGEN-FREE, THERMOPLASTIC SHEATHING COMPOUNDS
EN 50264-2-1:2008 Railway applications - Railway rolling stock power and control cables having special fire performance - Part 2-1: Cables with crosslinked elastomeric insulation - Single core cables
EN 61138:2007 CABLES FOR PORTABLE EARTHING AND SHORT-CIRCUITING EQUIPMENT
EN 60811-505:2012 Electric and optical fibre cables - Test methods for non-metallic materials - Part 505: Mechanical tests - Elongation at low temperature for insulations and sheaths
EN 50525-2-51:2011 Electric cables - Low voltage energy cables of rated voltages up to and including 450/750 V (U0/U) - Part 2-51: Cables for general applications - Oil resistant control cables with thermoplastic PVC insulation
EN 50525-2-31:2011 Electric cables - Low voltage energy cables of rated voltages up to and including 450/750 V (U0/U) - Part 2-31: Cables for general applications - Single core non-sheathed cables with thermoplastic PVC insulation
EN 50290-2-22 : 2001 AMD 1 2007 COMMUNICATION CABLES - PART 2-22: COMMON DESIGN RULES AND CONSTRUCTION - PVC SHEATHING COMPOUNDS
EN 50363-10-1:2005 Insulating, sheathing and covering materials for low voltage energy cables - Part 10-1: Miscellaneous sheathing compounds - Cross-linked polyvinyl chloride (XLPVC)
EN 50525-2-72:2011 Electric cables - Low voltage energy cables of rated voltages up to and including 450/750 V (U0/U) - Part 2-72: Cables for general applications - Flat divisible cables (cords) with thermoplastic PVC insulation
EN 50525-3-11:2011 Electric cables - Low voltage energy cables of rated voltages up to and including 450/750 V (U0/U) - Part 3-11: Cables with special fire performance - Flexible cables with halogen-free thermoplastic insulation, and low emission of smoke
EN 60811-506:2012 Electric and optical fibre cables - Test methods for non-metallic materials - Part 506: Mechanical tests - Impact test at low temperature for insulations and sheaths
EN 50525-2-81:2011 Electric cables - Low voltage energy cables of rated voltages up to and including 450/750 V (U0/U) - Part 2-81: Cables for general applications - Cables with crosslinked elastomeric covering for arc welding
EN 50363-9-1:2005 Insulating, sheathing and covering materials for low voltage energy cables - Part 9-1: Miscellaneous insulating compounds - Cross-linked polyvinyl chloride (XLPVC)
EN 50382-1 : 2008 AMD 1 2013 RAILWAY APPLICATIONS - RAILWAY ROLLING STOCK HIGH TEMPERATURE POWER CABLES HAVING SPECIAL FIRE PERFORMANCE - PART 1: GENERAL REQUIREMENTS
EN 50264-1:2008 Railway applications - Railway rolling stock power and control cables having special fire performance - Part 1: General requirements
EN 50525-2-71:2011 Electric cables - Low voltage energy cables of rated voltages up to and including 450/750 V (U0/U) - Part 2-71: Cables for general applications - Flat tinsel cables (cords) with thermoplastic PVC insulation
EN 50363-6 : 2005 AMD 1 2011 INSULATING, SHEATHING AND COVERING MATERIALS FOR LOW VOLTAGE ENERGY CABLES - PART 6: HALOGEN-FREE, CROSS-LINKED SHEATHING COMPOUNDS
EN 50525-3-31:2011 Electric cables - Low voltage energy cables of rated voltages up to and including 450/750 V (U0/U) - Part 3-31: Cables with special fire performance - Single core non-sheathed cables with halogen-free thermoplastic insulation, and low emission of smoke
EN 60794-2-30:2008 Optical fibre cables - Part 2-30: Indoor cables - Family specification for ribbon cables
EN 50264-3-2:2008 Railway applications - Railway rolling stock power and control cables having special fire performance - Part 3-2: Cables with crosslinked elastomeric insulation with reduced dimensions - Multicore cables
EN 61230:2008 LIVE WORKING - PORTABLE EQUIPMENT FOR EARTHING OR EARTHING AND SHORT-CIRCUITING
EN 50363-7:2005 Insulating, sheathing and covering materials for low voltage energy cables - Part 7: Halogen-free, thermoplastic insulating compounds
CEI EN 50525-2-71 : 2012 ELECTRIC CABLES - LOW VOLTAGE ENERGY CABLES OF RATED VOLTAGES UP TO AND INCLUDING 450/750 V (U[0]/U) - PART 2-71: CABLES FOR GENERAL APPLICATIONS - FLAT TINSEL CABLES (CORDS) WITH THERMOPLASTIC PVC INSULATION
04/30126718 DC : DRAFT DEC 2004 IEC 60189-1 ED.3 - LOW-FREQUENCY CABLES AND WIRES WITH PVC INSULATION AND PVC SHEATH - PART 1: GENERAL TEST AND MEASURING METHODS
BS EN 50525-2-11:2011 Electric cables. Low voltage energy cables of rated voltages up to and including 450/750V (U0/U) Cables for general applications. Flexible cables with thermoplastic PVC insulation
08/30188821 DC : 0 BS EN 50525-2-82 - ELECTRIC CABLES - LOW VOLTAGE ENERGY CABLES OF RATED VOLTAGES UP TO AND INCLUDING 450/750 V - PART 2-82: CABLES FOR GENERAL APPLICATIONS - CABLES WITH CROSS LINKED ELASTOMERIC INSULATION FOR DECORATIVE CHAINS
PREN 50288-1 : DRAFT 2011 MULTI-ELEMENT METALLIC CABLES USE IN ANALOGUE AND DIGITAL COMMUNICATION AND CONTROL - PART 1: GENERIC SPECIFICATION
I.S. EN 50525-2-81:2011 ELECTRIC CABLES - LOW VOLTAGE ENERGY CABLES OF RATED VOLTAGES UP TO AND INCLUDING 450/750 V (U[0]/U) - PART 2-81: CABLES FOR GENERAL APPLICATIONS - CABLES WITH CROSSLINKED ELASTOMERIC COVERING FOR ARC WELDING
UNE-EN 50264-3-2:2010 Railway applications - Railway rolling stock power and control cables having special fire performance -- Part 3-2: Cables with crosslinked elastomeric insulation with reduced dimensions - Multicore cables
I.S. EN 60811-505:2012 ELECTRIC AND OPTICAL FIBRE CABLES - TEST METHODS FOR NON-METALLIC MATERIALS - PART 505: MECHANICAL TESTS - ELONGATION AT LOW TEMPERATURE FOR INSULATIONS AND SHEATHS (IEC 60811-505:2012 (EQV))
08/30188793 DC : 0 BS EN 50525-2-31 - ELECTRIC CABLES - LOW VOLTAGE ENERGY CABLES OF RATED VOLTAGES UP TO AND INCLUDING 450/750 V - PART 2-31: CABLES FOR GENERAL APPLICATIONS - SINGLE CORE NON-SHEATHED CABLES WITH THERMOPLASTIC PVC INSULATION
05/30133180 DC : 0 EN 50382-1 - RAILWAY APPLICATIONS - HIGH TEMPERATURE POWER CABLES FOR RAILWAY ROLLING STOCK AND HAVING SPECIAL FIRE PERFORMANCE - PART 1: GENERAL REQUIREMENTS
BS EN 50525-3-31:2011 Electric cables. Low voltage energy cables of rated voltages up to and including 450/750 V (U0/U) Cables with special fire performance. Single core non-sheathed cables with halogen-free thermoplastic insulation, and low emission of smoke
EN 50290-2-24 : 2002 AMD 1 2008 COMMUNICATION CABLES - PART 2-24: COMMON DESIGN RULES AND CONSTRUCTION - PE SHEATHING
08/30159870 DC : DRAFT APR 2008 BS EN 60800 - HEATING CABLES WITH A RATED VOLTAGE OF 300/500 V FOR COMFORT HEATING AND PREVENTION OF ICE FORMATION
BS EN 50525-3-11:2011 Electric cables. Low voltage energy cables of rated voltages up to and including 450/750 V (U0/U) Cables with special fire performance. Flexible cables with halogen-free thermoplastic insulation, and low emission of smoke
CEI EN 50306-4 : 2003 RAILWAY APPLICATIONS - RAILWAY ROLLING STOCK CABLES HAVING SPECIAL FIRE PERFORMANCE - THIN WALL - PART 4: MULTICORE AND MULTIPAIR CABLES STANDARD WALL SHEATHED
CSA E60335.2.14 : 2005 HOUSEHOLD AND SIMILAR ELECTRICAL APPLIANCES - SAFETY - PART 2-14: PARTICULAR REQUIREMENTS FOR KITCHEN MACHINES
07/30164159 DC : 0 BS EN 60794-2-30 - OPTICAL FIBRE CABLES - PART 2-30: INDOOR OPTICAL FIBRE CABLES - FAMILY SPECIFICATION FOR OPTICAL FIBRE RIBBON CABLES
HD 605 S2:2008/corrigendum:2010 ELECTRIC CABLES - ADDITIONAL TEST METHODS
BS EN 50525-2-42:2011 Electric cables. Low voltage energy cables of rated voltages up to and including 450/750 V (U0/U) Cables for general applications. Single core non-sheathed cables with crosslinked EVA insulation
NF EN 50306-4 : 2003 RAILWAY APPLICATIONS - RAILWAY ROLLING STOCK CABLES HAVING SPECIAL FIRE PERFORMANCE - THIN WALL - PART 4: MULTICORE AND MULTIPAIR CABLES STANDARD WALL SHEATHED
08/30188818 DC : 0 BS EN 50525-2-81 - ELECTRIC CABLES - LOW VOLTAGE ENERGY CABLES OF RATED VOLTAGES UP TO AND INCLUDING 450/750 V - PART 2-81: CABLES FOR GENERAL APPLICATIONS - CABLES WITH CROSS LINKED ELASTOMERIC COVERING FOR ARC WELDING
BS EN 50264-2-1:2008 Railway applications. Railway rolling stock power and control cables having special fire performance Cables with crosslinked elastomeric insulation. Single core cables
BS EN 60811-506:2012 Electric and optical fibre cables. Test methods for non-metallic materials Mechanical tests. Impact test at low temperature for insulations and sheaths
IEC PAS 60092-510:2009 Electrical installations in ships - Part 510: Special features - High-voltage shore connection systems
CEI EN 50525-2-81 : 2012 ELECTRIC CABLES - LOW VOLTAGE ENERGY CABLES OF RATED VOLTAGES UP TO AND INCLUDING 450/750 V (U[0]/U) - PART 2-81: CABLES FOR GENERAL APPLICATIONS - CABLES WITH CROSSLINKED ELASTOMERIC COVERING FOR ARC WELDING
BS EN 50525-2-82:2011 Electric cables. Low voltage energy cables of rated voltages up to and including 450/750 V (U0/U) Cables for general applications. Cables with crosslinked elastomeric insulation for decorative chains
PREN 50525-2-72 : DRAFT 2008 ELECTRIC CABLES - LOW VOLTAGE ENERGY CABLES OF RATED VOLTAGES UP TO AND INCLUDING 450/750 V - PART 2-72: CABLES FOR GENERAL APPLICATIONS - FLAT DIVISIBLE CABLES (CORDS) WITH THERMOPLASTIC PVC INSULATION
CEI EN 50525-3-31 : 2012 ELECTRIC CABLES - LOW VOLTAGE ENERGY CABLES OF RATED VOLTAGES UP TO AND INCLUDING 450/750 V (U[0]/U) - PART 3-31: CABLES WITH SPECIAL FIRE PERFORMANCE - SINGLE CORE NON-SHEATHED CABLES WITH HALOGEN-FREE THERMOPLASTIC INSULATION, AND LOW EMISSION OF SMOKE
08/30188833 DC : 0 BS EN 50525-3-11 - ELECTRIC CABLES - LOW VOLTAGE ENERGY CABLES OF RATED VOLTAGES UP TO AND INCLUDING 450/750 V - PART 3-11: CABLES WITH SPECIAL FIRE PERFORMANCE - FLEXIBLE CABLES WITH HALOGEN-FREE THERMOPLASTIC INSULATION, AND LOW EMISSION OF SMOKE
I.S. EN 50363-9-1:2005 INSULATING, SHEATHING AND COVERING MATERIALS FOR LOW VOLTAGE ENERGY CABLES - PART 9-1: MISCELLANEOUS INSULATING COMPOUNDS - CROSS-LINKED POLYVINYL CHLORIDE (XLPVC)
IEC 60227-4:1992+AMD1:1997 CSV Polyvinyl chloride insulated cables of rated voltages up to and including 450/750 V - Part 4: Sheathed cables for fixed wiring
CEI EN 60794-2-30 : 2010 OPTICAL FIBRE CABLES - PART 2-30: INDOOR CABLES - FAMILY SPECIFICATION FOR RIBBON CABLES
I.S. EN 60794-2-30:2008 OPTICAL FIBRE CABLES - PART 2-30: INDOOR CABLES - FAMILY SPECIFICATION FOR RIBBON CABLES
I.S. EN 62012-1:2002 MULTICORE AND SYMMETRICAL PAIR/QUAD CABLES FOR DIGITAL COMMUNICATIONS TO BE USED IN HARSH ENVIRONMENTS - PART 1: GENERIC SPECIFICATION
I.S. EN 50363-10-1:2005 INSULATING, SHEATHING AND COVERING MATERIALS FOR LOW VOLTAGE ENERGY CABLES - PART 10-1: MISCELLANEOUS SHEATHING COMPOUNDS - CROSS-LINKED POLYVINYL CHLORIDE (XLPVC)
BS EN 50290-2-27:2002+A1:2007 Communication cables Common design rules and construction. Halogen free flame retardant thermoplastic sheathing compounds
I.S. EN 50525-3-31:2011 ELECTRIC CABLES - LOW VOLTAGE ENERGY CABLES OF RATED VOLTAGES UP TO AND INCLUDING 450/750 V (U[0]/U) - PART 3-31: CABLES WITH SPECIAL FIRE PERFORMANCE - SINGLE CORE NON-SHEATHED CABLES WITH HALOGEN-FREE THERMOPLASTIC INSULATION, AND LOW EMISSION OF SMOKE
I.S. EN 50264-3-2:2008 RAILWAY APPLICATIONS - RAILWAY ROLLING STOCK POWER AND CONTROL CABLES HAVING SPECIAL FIRE PERFORMANCE - PART 3-2: CABLES WITH CROSSLINKED ELASTOMERIC INSULATION WITH REDUCED DIMENSIONS - MULTICORE CABLES
I.S. EN 50525-2-42:2011 ELECTRIC CABLES - LOW VOLTAGE ENERGY CABLES OF RATED VOLTAGES UP TO AND INCLUDING 450/750 V (U[0]/U) - PART 2-42: CABLES FOR GENERAL APPLICATIONS - SINGLE CORE NON-SHEATHED CABLES WITH CROSSLINKED EVA INSULATION
UNE-EN 50525-2-71:2012 Electric cables - Low voltage energy cables of rated voltages up to and including 450/750 V (Uo/U) -- Part 2-71: Cables for general applications - Flat tinsel cables (cords) with thermoplastic PVC insulation
CEI EN 60708 : 2006 LOW-FREQUENCY CABLES WITH POLYOLEFIN INSULATION AND MOISTURE BARRIER POLYOLEFIN SHEATH
I.S. EN 50525-2-11:2011 ELECTRIC CABLES - LOW VOLTAGE ENERGY CABLES OF RATED VOLTAGES UP TO AND INCLUDING 450/750 V (U[0]/U) - PART 2-11: CABLES FOR GENERAL APPLICATIONS - FLEXIBLE CABLES WITH THERMOPLASTIC PVC INSULATION
I.S. EN 50525-2-12:2011 ELECTRIC CABLES - LOW VOLTAGE ENERGY CABLES OF RATED VOLTAGES UP TO AND INCLUDING 450/750 V (U[0]/U) - PART 2-12: CABLES FOR GENERAL APPLICATIONS - CABLES WITH THERMOPLASTIC PVC INSULATION FOR EXTENSIBLE LEADS
I.S. EN 50363-3:2005 INSULATING, SHEATHING AND COVERING MATERIALS FOR LOW VOLTAGE ENERGY CABLES - PART 3: PVC INSULATING COMPOUNDS
NF EN 61230 : 2009 LIVE WORKING - PORTABLE EQUIPMENT FOR EARTHING OR EARTHING AND SHORT-CIRCUITING
UNE-EN 60794-2-30:2011 Optical fibre cables - Part 2-30: Indoor cables - Family specification for ribbon cables
NF EN 50264-3-1 : 2008 RAILWAY APPLICATIONS - RAILWAY ROLLING STOCK POWER AND CONTROL CABLES HAVING SPECIAL FIRE PERFORMANCE - PART 3-1: CABLES WITH CROSSLINKED ELASTOMERIC INSULATION WITH REDUCED DIMENSIONS - SINGLE CORE CABLES
IEC 60800:2009 Heating cables with a rated voltage of 300/500 V for comfort heating and prevention of ice formation
UNE-EN 50525-3-21:2012 Electric cables - Low voltage energy cables of rated voltages up to and including 450/750 V (Uo/U) - Part 3-21: Cables with special fire performance - Flexible cables with halogen-free crosslinked insulation, and low emission of smoke
PREN 50525-2-41 : DRAFT 2008 ELECTRIC CABLES - LOW VOLTAGE ENERGY CABLES OF RATED VOLTAGES UP TO AND INCLUDING 450/750 V - PART 2-41: CABLES FOR GENERAL APPLICATIONS - SINGLE CORE CABLES WITH CROSSLINKED SILICONE RUBBER INSULATION
UNE-EN 50525-2-81:2012 Electric cables - Low voltage energy cables of rated voltages up to and including 450/750 V (Uo/U) - Part 2-81: Cables for general applications - Cables with crosslinked elastomeric covering for arc welding
CEI EN 50525-2-42 : 2012 ELECTRIC CABLES - LOW VOLTAGE ENERGY CABLES OF RATED VOLTAGES UP TO AND INCLUDING 450/750 V (U[0]/U) - PART 2-42: CABLES FOR GENERAL APPLICATIONS - SINGLE CORE NON-SHEATHED CABLES WITH CROSSLINKED EVA INSULATION
CEI EN 50290-2-30 : 2002 COMMUNICATION CABLES - PART 2-30: COMMON DESIGN RULES AND CONSTRUCTION POLY(TETRAFLUOROETHYLENE-HEXAFLUOROPROPYLENE) (FEP) INSULATION AND SHEATHING
PREN 50525-2-11 : DRAFT 2008 ELECTRIC CABLES - LOW VOLTAGE ENERGY CABLES OF RATED VOLTAGES UP TO AND INCLUDING 450/750 V - PART 2-11: CABLES FOR GENERAL APPLICATIONS - FLEXIBLE CABLES WITH THERMOPLASTIC PVC INSULATION
DEFSTAN 02-526/2(2008) : 2008 REQUIREMENTS FOR CABLES ELECTRIC, ELASTOMERIC, LIMITED FIRE HAZARD SHEATHED FOR GENERAL SERVICES
IEC 60840:2011 RLV Power cables with extruded insulation and their accessories for rated voltages above 30 kV (<em>U</em><sub>m</sub> = 36 kV) up to 150 kV (<em>U</em><sub>m</sub> = 170 kV) - Test methods and requirements
I.S. EN 50363-5:2005 INSULATING, SHEATHING AND COVERING MATERIALS FOR LOW VOLTAGE ENERGY CABLES - PART 5: HALOGEN-FREE, CROSS-LINKED INSULATING COMPOUNDS
IEC PAS 60794-2-50:2004 Optical fibre cables - Part 2-50: Indoor optical fibre cables - Family specification for simplex and duplex cables for use in patch cords
IEC 60227-5:2011 Polyvinyl chloride insulated cables of rated voltages up to and including 450/750 V - Part 5: Flexible cables (cords)
EN 50306-1:2002 Railway applications - Railway rolling stock cables having special fire performance - Thin wall - Part 1: General requirements
IEC 60811-506:2012 Electric and optical fibre cables - Test methods for non-metallic materials - Part 506: Mechanical tests - Impact test at low temperature for insulations and sheaths
BS EN 50363-10-2:2005 Insulating, sheathing and covering materials for low-voltage energy cables Miscellaneous sheathing compounds. Thermoplastic polyurethane
PREN 50525-3-11 : DRAFT 2008 ELECTRIC CABLES - LOW VOLTAGE ENERGY CABLES OF RATED VOLTAGES UP TO AND INCLUDING 450/750 V - PART 3-11: CABLES WITH SPECIAL FIRE PERFORMANCE - FLEXIBLE CABLES WITH HALOGEN-FREE THERMOPLASTIC INSULATION, AND LOW EMISSION OF SMOKE
BS EN 60794-2-50:2008 Optical fibre cables Indoor cables. Family specification for simplex and duplex cables for use in terminated cable assemblies
BS EN 50290-2-22:2002 Communication cables Common design rules and construction. PVC sheathing compounds
BS EN 50382-1 : 2008 RAILWAY APPLICATIONS - RAILWAY ROLLING STOCK HIGH TEMPERATURE POWER CABLES HAVING SPECIAL FIRE PERFORMANCE - PART 1: GENERAL REQUIREMENTS
UNE-EN 50525-2-83:2012 Electric cables - Low voltage energy cables of rated voltages up to and including 450/750 V (Uo/U) - Part 2-83: Cables for general applications - Multicore cables with crosslinked silicone rubber insulation
BS EN 50290-2-24 : 2002 COMMUNICATION CABLES - PART 2-24: COMMON DESIGN RULES AND CONSTRUCTION - PE SHEATHING
BS EN 50264-1:2008 Railway applications. Railway rolling stock power and control cables having special fire performance General requirements
PREN 50525-2-12 : DRAFT 2008 ELECTRIC CABLES - LOW VOLTAGE ENERGY CABLES OF RATED VOLTAGES UP TO AND INCLUDING 450/750 V - PART 2-12: CABLES FOR GENERAL APPLICATIONS - EXTENSIBLE LEADS WITH THERMOPLASTIC PVC INSULATION
BS EN 50525-3-21:2011 Electric cables. Low voltage energy cables of rated voltages up to and including 450/750 V (U0/U) Cables with special fire performance. Flexible cables with halogen-free crosslinked insulation, and low emission of smoke
BS EN 60708:2005 Low-frequency cables with polyolefin insulation and moisture barrier polyolefin sheath
BS EN 50290-2-26:2002 Communication cables Common design rules and construction. Halogen free flame retardant insulation compounds
BS EN 50525-2-81:2011 Electric cables. Low voltage energy cables of rated voltages up to and including 450/750 V (U0/U) Cables for general applications. Cables with crosslinked elastomeric covering for arc welding
04/30124745 DC : DRAFT NOV 2004
CEI EN 50264-2-1 : 2009 RAILWAY APPLICATIONS - RAILWAY ROLLING STOCK POWER AND CONTROL CABLES HAVING SPECIAL FIRE PERFORMANCE - PART 2-1: CABLES WITH CROSSLINKED ELASTOMERIC INSULATION - SINGLE CORE CABLES
CEI EN 50525-3-41 : 2012 ELECTRIC CABLES - LOW VOLTAGE ENERGY CABLES OF RATED VOLTAGES UP TO AND INCLUDING 450/750 V (U[0]/U) - PART 3-41: CABLES WITH SPECIAL FIRE PERFORMANCE - SINGLE CORE NON-SHEATHED CABLES WITH HALOGEN-FREE CROSSLINKED INSULATION, AND LOW EMISSION OF SMOKE
CEI EN 50525-2-11 : 2012 ELECTRIC CABLES - LOW VOLTAGE ENERGY CABLES OF RATED VOLTAGES UP TO AND INCLUDING 450/750 V (U[0]/U) - PART 2-11: CABLES FOR GENERAL APPLICATIONS - FLEXIBLE CABLES WITH THERMOPLASTIC PVC INSULATION
BS EN 50264-3-2:2008 Railway applications. Railway rolling stock power and control cables having special fire performance Cables with crosslinked elastomeric insulation with reduced dimensions. Multicore cables
BS EN 60794-2-42:2008 Optical fibre cables Indoor optical fibre cables. Product specification for simplex and duplex cables with A4 fibres
08/30188771 DC : 0 BS EN 50525-2-11 - ELECTRIC CABLES - LOW VOLTAGE ENERGY CABLES OF RATED VOLTAGES UP TO AND INCLUDING 450/750 V - PART 2-11: CABLES FOR GENERAL APPLICATIONS - FLEXIBLE CABLES WITH THERMOPLASTIC PVC INSULATION
BS EN 50306-2:2002 Railway applications. Railway rolling stock cables having special fire performance. Thin wall Single core cables
NF EN 50306-3 : 2003 RAILWAY APPLICATIONS - RAILWAY ROLLING STOCK CABLES HAVING SPECIAL FIRE PERFORMANCE - THIN WALL - PART 3: SINGLE CORE AND MULTICORE CABLES (PAIRS, TRIPLES AND QUADS) SCREENED AND THIN WALL SHEATHED
BS EN 50305:2002 Railway applications. Railway rolling stock cables having special fire performance. Test methods
BS EN 50525-2-83:2011 Electric cables. Low voltage energy cables of rated voltages up to and including 450/750 V (U0/U) Cables for general applications. Multicore cables with crosslinked silicone rubber insulation
UNE-EN 50525-2-42:2012 Electric cables - Low voltage energy cables of rated voltages up to and including 450/750 V (Uo/U) -- Part 2-42: Cables for general applications - Single core non-sheathed cables with crosslinked EVA insulation
CEI EN 50306-2 : 2003 RAILWAY APPLICATIONS - RAILWAY ROLLING STOCK CABLES HAVING SPECIAL FIRE PERFORMANCE - THIN WALL - PART 2: SINGLE CORE CABLES
CEI EN 50264-2-2 : 2009 RAILWAY APPLICATIONS - RAILWAY ROLLING STOCK POWER AND CONTROL CABLES HAVING SPECIAL FIRE PERFORMANCE - PART 2-2: CABLES WITH CROSSLINKED ELASTOMERIC INSULATION - MULTICORE CABLES
05/30131385 DC : DRAFT MAR 2005 IEC 61156-1 ED 3 - MULTICORE AND SYMMETRICAL PAIR/QUAD CABLES FOR DIGITAL COMMUNICATIONS - PART 1: GENERIC SPECIFICATION
UNE-EN 50264-2-1:2010 Railway applications - Railway rolling stock power and control cables having special fire performance -- Part 2-1: Cables with crosslinked elastomeric insulation - Single core cables
UNE-EN 50525-2-11:2012 Electric cables - Low voltage energy cables of rated voltages up to and including 450/750 V (Uo/U) - Part 2-11: Cables for general applications - Flexible cables with thermoplastic PVC insulation
PREN 50525-2-71 : DRAFT 2008 ELECTRIC CABLES - LOW VOLTAGE ENERGY CABLES OF RATED VOLTAGES UP TO AND INCLUDING 450/750 V - PART 2-71: CABLES FOR GENERAL APPLICATIONS - FLAT TINSEL CABLES (CORDS) WITH THERMOPLASTIC PVC INSULATION
NF EN 50306-2 : 2003 RAILWAY APPLICATIONS - RAILWAY ROLLING STOCK CABLES HAVING SPECIAL FIRE PERFORMANCE - THIN WALL - PART 2: SINGLE CORE CABLES
CEI EN 50525-2-83 : 2012 ELECTRIC CABLES - LOW VOLTAGE ENERGY CABLES OF RATED VOLTAGES UP TO AND INCLUDING 450/750 V (U[0]/U) - PART 2-83: CABLES FOR GENERAL APPLICATIONS - MULTICORE CABLES WITH CROSSLINKED SILICONE RUBBER INSULATION
I.S. EN 60794-2-50:2008 OPTICAL FIBRE CABLES - PART 2-50: INDOOR CABLES - FAMILY SPECIFICATION FOR SIMPLEX AND DUPLEX CABLES FOR USE IN TERMINATED CABLE ASSEMBLIES
I.S. EN 61230:2008 LIVE WORKING - PORTABLE EQUIPMENT FOR EARTHING OR EARTHING AND SHORT-CIRCUITING
BS EN 187000:1994 Generic specification for optical fibre cables
CEI EN 50264-3-2 : 2009 RAILWAY APPLICATIONS - RAILWAY ROLLING STOCK POWER AND CONTROL CABLES HAVING SPECIAL FIRE PERFORMANCE - PART 3-2: CABLES WITH CROSSLINKED ELASTOMERIC INSULATION WITH REDUCED DIMENSIONS - MULTICORE CABLES
IEC 60840 REDLINE : 4.0 POWER CABLES WITH EXTRUDED INSULATION AND THEIR ACCESSORIES FOR RATED VOLTAGES ABOVE 30 KV (U[M] = 36 KV) UP TO 150 KV (U[M] = 170 KV) - TEST METHODS AND REQUIREMENTS
IEC 60245-4:2011 Rubber insulated cables - Rated voltages up to and including 450/750 V - Part 4: Cords and flexible cables
NF EN 50382-2 : 2008 AMD 1 2013 RAILWAY APPLICATIONS - RAILWAY ROLLING STOCK HIGH TEMPERATURE POWER CABLES HAVING SPECIAL FIRE PERFORMANCE - PART 2: SINGLE CORE SILICONE RUBBER INSULATED CABLES FOR 120 DEGREES C OR 150 DEGREES C
NF EN 50290-2-27 : 2002 AMD 1 2008 COMMUNICATION CABLES - PART 2-27: COMMON DESIGN RULES AND CONSTRUCTION - HALOGEN FREE FLAME RETARDANT THERMOPLASTIC SHEATHING COMPOUNDS
IEC 60227-6:2001 Polyvinyl chloride insulated cables of rated voltages up to and including 450/750 V - Part 6: Lift cables and cables for flexible connections
IEC 62255-1:2003 Multicore and symmetrical pair/quad cables for broadband digital communications (high bit rate digital access telecommunication networks) - Outside plant cables - Part 1: Generic specification
I.S. EN 50363-6:2005 INSULATING, SHEATHING AND COVERING MATERIALS FOR LOW VOLTAGE ENERGY CABLES - PART 6: HALOGEN-FREE, CROSS-LINKED SHEATHING COMPOUNDS
IEC TS 62100:2004 Cables for aeronautical ground lighting primary circuits
IEC 62067 : 2.0EN+(REDLINE+VERSION) POWER CABLES WITH EXTRUDED INSULATION AND THEIR ACCESSORIES FOR RATED VOLTAGES ABOVE 150 KV (U[M] = 170 KV) UP TO 500 KV (U[M] = 550 KV) - TEST METHODS AND REQUIREMENTS
IEC 60092-351:2004 Electrical installations in ships - Part 351: Insulating materials for shipboard and offshore units, power, control, instrumentation, telecommunication and data cables
IEC 60794-2-50:2008 Optical fibre cables - Part 2-50: Indoor cables - Family specification for simplex and duplex cables for use in terminated cable assemblies
IEC 60811-504:2012 Electric and optical fibre cables - Test methods for non-metallic materials - Part 504: Mechanical tests - Bending tests at low temperature for insulation and sheaths
UNE-EN 50264-1:2010 Railway applications - Railway rolling stock power and control cables having special fire performance -- Part 1: General requirements
CEI EN 50306-3 : 2003 RAILWAY APPLICATIONS - RAILWAY ROLLING STOCK CABLES HAVING SPECIAL FIRE PERFORMANCE - THIN WALL - PART 3: SINGLE CORE AND MULTICORE CABLES (PAIRS, TRIPLES AND QUADS) SCREENED AND THIN WALL SHEATHED
05/30128938 DC : DRAFT FEB 2005 IEC 61138 ED.3 - CABLES FOR PORTABLE EARTHING AND SHORT-CIRCUITING EQUIPMENT
08/30188836 DC : 0 BS EN 50525-3-21 - ELECTRIC CABLES - LOW VOLTAGE ENERGY CABLES OF RATED VOLTAGES UP TO AND INCLUDING 450/750 V - PART 3-21: CABLES WITH SPECIAL FIRE PERFORMANCE - FLEXIBLE CABLES WITH HALOGEN-FREE CROSS LINKED INSULATION, AND LOW EMISSION OF SMOKE
08/30188826 DC : 0 BS EN 50525-2-83 - ELECTRIC CABLES - LOW VOLTAGE ENERGY CABLES OF RATED VOLTAGES UP TO AND INCLUDING 450/750 V - PART 2-83: CABLES FOR GENERAL APPLICATIONS - MULTICORE CABLES WITH CROSS LINKED SILICONE RUBBER INSULATION
CEI EN 60794-2-42 : 2009 OPTICAL FIBRE CABLES - PART 2-42: INDOOR OPTICAL FIBRE CABLES - PRODUCT SPECIFICATION FOR SIMPLEX AND DUPLEX CABLES WITH A4 FIBRES
BS EN 50363-1:2005 Insulating, sheathing and covering materials for low voltage energy cables Cross-linked elastomeric insulating compounds
11/30255235 DC : 0 BS EN 50288-1 - MULTI-ELEMENT METALIC CABLES USED IN ANALOUGE AND DIGITAL COMUNICATION AND CONTROL - PART 1: GENEIC SPECIFICATION
NF EN 60794-2-50 : 2009 OPTICAL FIBRE CABLES - PART 2-50: INDOOR OPTICAL FIBRE CABLES - FAMILY SPECIFICATION FOR SIMPLEX AND DUPLEX CABLES FOR USE IN TERMINATED CABLE ASSEMBLIES
BS EN 50306-1:2002 Railway applications. Railway rolling stock cables having special fire performance. Thin wall General requirements
CEI EN 60794-2-50 : 2010 OPTICAL FIBRE CABLES - PART 2-50: INDOOR CABLES - FAMILY SPECIFICATION FOR SIMPLEX AND DUPLEX CABLES FOR USE IN TERMINATED CABLE ASSEMBLIES
BS EN 50525-2-41:2011 Electric cables. Low voltage energy cables of rated voltages up to and including 450/750 V (U0/U) Cables for general applications. Single core cables with crosslinked silicone rubber insulation
08/30188779 DC : 0 BS EN 50525-2-12 - ELECTRIC CABLES - LOW VOLTAGE ENERGY CABLES OF RATED VOLTAGES UP TO AND INCLUDING 450/750 V - PART 2-12: CABLES FOR GENERAL APPLICATIONS - EXTENSIBLE LEADS WITH THERMOPLASTIC PVC INSULATION
UNE-EN 50264-3-1:2010 Railway applications - Railway rolling stock power and control cables having special fire performance -- Part 3-1: Cables with crosslinked elastomeric insulation with reduced dimensions - Single core cables
UNE-EN 50525-2-12:2012 Electric cables - Low voltage energy cables of rated voltages up to and including 450/750 V (Uo/U) -- Part 2-12: Cables for general applications - Cables with thermoplastic PVC insulation for extensible leads
BS EN 50525-2-21:2011 Electric cables. Low voltage energy cables of rated voltages up to and including 450/750 V (U0/U) Cables for general applications. Flexible cables with crosslinked elastomeric insulation
PREN 50525-2-21 : DRAFT 2008 ELECTRIC CABLES - LOW VOLTAGE ENERGY CABLES OF RATED VOLTAGES UP TO AND INCLUDING 450/750 V - PART 2-21: CABLES FOR GENERAL APPLICATIONS - FLEXIBLE CABLES WITH CROSSLINKED ELASTOMERIC INSULATION
CEI EN 50525-2-21 : 2012 ELECTRIC CABLES - LOW VOLTAGE ENERGY CABLES OF RATED VOLTAGES UP TO AND INCLUDING 450/750 V (U[0]/U) - PART 2-21: CABLES FOR GENERAL APPLICATIONS - FLEXIBLE CABLES WITH CROSSLINKED ELASTOMERIC INSULATION
PREN 50525-2-31 : DRAFT 2008 ELECTRIC CABLES - LOW VOLTAGE ENERGY CABLES OF RATED VOLTAGES UP TO AND INCLUDING 450/750 V - PART 2-31: CABLES FOR GENERAL APPLICATIONS - SINGLE CORE NON-SHEATHED CABLES WITH THERMOPLASTIC PVC INSULATION
PREN 50525-2-51 : DRAFT 2008 ELECTRIC CABLES - LOW VOLTAGE ENERGY CABLES OF RATED VOLTAGES UP TO AND INCLUDING 450/750 V - PART 2-51: CABLES FOR GENERAL APPLICATIONS - OIL RESISTANT CONTROL CABLES WITH THERMOPLASTIC PVC INSULATION
BS EN 50363-4-1:2005 Insulating, sheathing and covering materials for low voltage energy cables PVC sheathing compounds
CEI EN 50306-1 : 2003 RAILWAY APPLICATIONS - RAILWAY ROLLING STOCK CABLES HAVING SPECIAL FIRE PERFORMANCE - THIN WALL - PART 1: GENERAL REQUIREMENTS
NF EN 50290-2-22 : 2002 AMD 1 2008 COMMUNICATION CABLES - PART 2-22: COMMON DESIGN RULES AND CONSTRUCTION - PVC SHEATHING COMPOUNDS
BS EN 50363-4-2:2005 Insulating, sheathing and covering materials for low voltage energy cables PVC covering compounds
BS EN 50264-3-1:2008 Railway applications. Railway rolling stock power and control cables having special fire performance Cables with crosslinked elastomeric insulation with reduced dimensions. Single core cables
CEI EN 50264-3-1 : 2009 RAILWAY APPLICATIONS - RAILWAY ROLLING STOCK POWER AND CONTROL CABLES HAVING SPECIAL FIRE PERFORMANCE - PART 3-1: CABLES WITH CROSSLINKED ELASTOMERIC INSULATION WITH REDUCED DIMENSIONS - SINGLE CORE CABLES
BS EN 60794-2-30:2008 Optical fibre cables Indoor cables. Family specification for ribbon cables
CEI EN 62012-1 : 2003 MULTICORE AND SYMMETRICAL PAIR/QUAD CABLES FOR DIGITAL COMMUNICATIONS TO BE USED IN HARSH ENVIRONMENT - PART 1: GENERIC SPECIFICATION
08/30188810 DC : 0 BS EN 50525-2-71 - ELECTRIC CABLES - LOW VOLTAGE ENERGY CABLES OF RATED VOLTAGES UP TO AND INCLUDING 450/750 V - PART 2-71: CABLES FOR GENERAL APPLICATIONS - FLAT TINSEL CABLES (CORDS) WITH THERMOPLASTIC PVC INSULATION
BS EN 50525-2-51:2011 Electric cables. Low voltage energy cables of rated voltages up to and including 450/750 V (U0/U) Cables for general applications. Oil resistant control cables with thermoplastic PVC insulation
05/30136249 DC : 0 EN 50264-1 - RAILWAY APPLICATIONS - RAILWAY ROLLING STOCK POWER AND CONTROL CABLES HAVING SPECIAL FIRE PERFORMANCE - PART 1: GENERAL REQUIREMENTS
BS EN 60811-504:2012 Electric and optical fibre cables. Test methods for non-metallic materials Mechanical tests. Bending tests at low temperature for insulation and sheaths
BS EN 50306-4:2002 Railway applications. Railway rolling stock cables having special fire performance. Thin wall Multicore and multipair cables standard wall sheathed
05/30133183 DC : 0 EN 50382-2 - RAILWAY APPLICATIONS - HIGH TEMPERATURE POWER CABLES FOR RAILWAY ROLLING STOCK AND HAVING SPECIAL FIRE PERFORMANCE - PART 2: SINGLE CORE SILICONE RUBBER INSULATED CABLES FOR 120 DEGREES C OR 150 DEGREE C
CEI EN 50264-1 : 2009 RAILWAY APPLICATIONS - RAILWAY ROLLING STOCK POWER AND CONTROL CABLES HAVING SPECIAL FIRE PERFORMANCE - PART 1: GENERAL REQUIREMENTS
PREN 50525-2-82 : DRAFT 2008 ELECTRIC CABLES - LOW VOLTAGE ENERGY CABLES OF RATED VOLTAGES UP TO AND INCLUDING 450/750 V - PART 2-82: CABLES FOR GENERAL APPLICATIONS - CABLES WITH CROSSLINKED ELASTOMERIC INSULATION FOR DECORATIVE CHAINS
08/30188799 DC : 0 BS EN 50525-2-42 - ELECTRIC CABLES - LOW VOLTAGE ENERGY CABLES OF RATED VOLTAGES UP TO AND INCLUDING 450/750 V - PART 2-42: CABLES FOR GENERAL APPLICATIONS - SINGLE CORE NON-SHEATHED CABLES WITH CROSS LINKED EVA INSULATION
I.S. EN 50525-2-83:2011 ELECTRIC CABLES - LOW VOLTAGE ENERGY CABLES OF RATED VOLTAGES UP TO AND INCLUDING 450/750 V (U[0]/U) - PART 2-83: CABLES FOR GENERAL APPLICATIONS - MULTICORE CABLES WITH CROSSLINKED SILICONE RUBBER INSULATION
UNE-EN 60811-506:2012 Electric and optical fibre cables - Test methods for non-metallic materials - Part 506: Mechanical tests - Impact test at low temperature for insulations and sheaths
07/30170224 DC : DRAFT AUG 2007 BS EN 61230 - LIVE WORKING - PORTABLE EQUIPMENT FOR EARTHING OR EARTHING AND SHORT-CIRCUITING
NF EN 50305 : 2002 RAILWAY APPLICATIONS - RAILWAY ROLLING STOCK CABLES HAVING SPECIAL FIRE PERFORMANCE - TEST METHODS
IEC 60227-7:1995+AMD1:2003+AMD2:2011 CSV Polyvinyl chloride insulated cables of rated voltages up to and including 450/750 V - Part 7: Flexible cables screened and unscreened with two or more conductors
BS EN 50363-10-1:2005 Insulating, sheathing and covering materials for low-voltage energy cables Miscellaneous sheathing compounds. Cross-linked polyvinyl chloride (XLPVC)
BS EN 50363-7:2005 Insulating, sheathing and covering materials for low voltage energy cables Halogen-free, thermoplastic insulating compounds
I.S. EN 60811-504:2012 ELECTRIC AND OPTICAL FIBRE CABLES - TEST METHODS FOR NON-METALLIC MATERIALS - PART 504: MECHANICAL TESTS - BENDING TESTS AT LOW TEMPERATURE FOR INSULATION AND SHEATHS (IEC 60811-504:2012 (EQV))
NF EN 50290-2-26 : 2002 AMD 1 2008 COMMUNICATION CABLES - PART 2-26: COMMON DESIGN RULES AND CONSTRUCTION - HALOGEN FREE FLAME RETARDANT INSULATION COMPOUNDS
I.S. HD 605:2008 ELECTRIC CABLES - ADDITIONAL TEST METHODS
I.S. EN 50525-3-21:2011 ELECTRIC CABLES - LOW VOLTAGE ENERGY CABLES OF RATED VOLTAGES UP TO AND INCLUDING 450/750 V (U[0]/U) - PART 3-21: CABLES WITH SPECIAL FIRE PERFORMANCE - FLEXIBLE CABLES WITH HALOGEN-FREE CROSSLINKED INSULATION, AND LOW EMISSION OF SMOKE
CEI EN 50525-3-21 : 2012 ELECTRIC CABLES - LOW VOLTAGE ENERGY CABLES OF RATED VOLTAGES UP TO AND INCLUDING 450/750 V (U[0]/U) - PART 3-21: CABLES WITH SPECIAL FIRE PERFORMANCE - FLEXIBLE CABLES WITH HALOGEN-FREE CROSSLINKED INSULATION, AND LOW EMISSION OF SMOKE
I.S. EN 50382-2:2008 RAILWAY APPLICATIONS - RAILWAY ROLLING STOCK HIGH TEMPERATURE POWER CABLES HAVING SPECIAL FIRE PERFORMANCE - PART 2: SINGLE CORE SILICONE RUBBER INSULATED CABLES FOR 120 DEGREES C OR 150 DEGREES C
I.S. EN 50525-3-11:2011 ELECTRIC CABLES - LOW VOLTAGE ENERGY CABLES OF RATED VOLTAGES UP TO AND INCLUDING 450/750 V (U[0]/U) - PART 3-11: CABLES WITH SPECIAL FIRE PERFORMANCE - FLEXIBLE CABLES WITH HALOGEN-FREE THERMOPLASTIC INSULATION, AND LOW EMISSION OF SMOKE
I.S. EN 50363-4-2:2005 INSULATING, SHEATHING AND COVERING MATERIALS FOR LOW VOLTAGE ENERGY CABLES - PART 4-2: PVC COVERING COMPOUNDS
I.S. EN 50525-2-72:2011 ELECTRIC CABLES - LOW VOLTAGE ENERGY CABLES OF RATED VOLTAGES UP TO AND INCLUDING 450/750 V (U[0]/U) - PART 2-72: CABLES FOR GENERAL APPLICATIONS - FLAT DIVISIBLE CABLES (CORDS) WITH THERMOPLASTIC PVC INSULATION
NF EN 50264-2-2 : 2008 RAILWAY APPLICATIONS - RAILWAY ROLLING STOCK POWER AND CONTROL CABLES HAVING SPECIAL FIRE PERFORMANCE - PART 2-2: CABLES WITH CROSSLINKED ELASTOMERIC INSULATION - MULTICORE CABLES
I.S. EN 50363-1:2005 INSULATING, SHEATHING AND COVERING MATERIALS FOR LOW VOLTAGE ENERGY CABLES - PART 1: CROSS-LINKED ELASTOMERIC INSULATING COMPOUNDS
I.S. EN 60708:2005 LOW-FREQUENCY CABLES WITH POLYOLEFIN INSULATION AND MOISTURE BARRIER POLYOLEFIN SHEATH
BS EN 60335-2-14 : 2006 HOUSEHOLD AND SIMILAR ELECTRICAL APPLIANCES - SAFETY - PART 2-14: PARTICULAR REQUIREMENTS FOR KITCHEN MACHINES
I.S. EN 50363-2-2:2005 INSULATING, SHEATHING AND COVERING MATERIALS FOR LOW VOLTAGE ENERGY CABLES - PART 2-2: CROSS-LINKED ELASTOMERIC COVERING COMPOUNDS
I.S. EN 50382-1:2008 RAILWAY APPLICATIONS - RAILWAY ROLLING STOCK HIGH TEMPERATURE POWER CABLES HAVING SPECIAL FIRE PERFORMANCE - PART 1: GENERAL REQUIREMENTS
IEC 60189-1:2007 Low-frequency cables and wires with PVC insulation and PVC sheath - Part 1: General test and measuring methods
I.S. EN 50290-2-21:2001 COMMUNICATION CABLES - PART 2-21: COMMON DESIGN RULES AND CONSTRUCTION - PVC INSULATION COMPOUNDS
I.S. EN 60811-506:2012 ELECTRIC AND OPTICAL FIBRE CABLES - TEST METHODS FOR NON-METALLIC MATERIALS - PART 506: MECHANICAL TESTS - IMPACT TEST AT LOW TEMPERATURE FOR INSULATIONS AND SHEATHS (IEC 60811-506:2012 (EQV))
I.S. EN 50525-2-82:2011 ELECTRIC CABLES - LOW VOLTAGE ENERGY CABLES OF RATED VOLTAGES UP TO AND INCLUDING 450/750 V (U[0]/U) - PART 2-82: CABLES FOR GENERAL APPLICATIONS - CABLES WITH CROSSLINKED ELASTOMERIC INSULATION FOR DECORATIVE CHAINS
CEI EN 50525-2-82 : 2012 ELECTRIC CABLES - LOW VOLTAGE ENERGY CABLES OF RATED VOLTAGES UP TO AND INCLUDING 450/750 V (U[0]/U) - PART 2-82: CABLES FOR GENERAL APPLICATIONS - CABLES WITH CROSSLINKED ELASTOMERIC INSULATION FOR DECORATIVE CHAINS
IEC 60227-1:2007 Polyvinyl chloride insulated cables of rated voltages up to and including 450/750 V - Part 1: General requirements
I.S. EN 60335-2-14:2006 HOUSEHOLD AND SIMILAR ELECTRICAL APPLIANCES - SAFETY - PART 2-14: PARTICULAR REQUIREMENTS FOR KITCHEN MACHINES (IEC 60335-2-14:2006 (MOD))
IEC 61138:2007 Cables for portable earthing and short-circuiting equipment
I.S. EN 50525-2-31:2011 ELECTRIC CABLES - LOW VOLTAGE ENERGY CABLES OF RATED VOLTAGES UP TO AND INCLUDING 450/750 V (U[0]/U) - PART 2-31: CABLES FOR GENERAL APPLICATIONS - SINGLE CORE NON-SHEATHED CABLES WITH THERMOPLASTIC PVC INSULATION
I.S. EN 50264-1:2008 RAILWAY APPLICATIONS - RAILWAY ROLLING STOCK POWER AND CONTROL CABLES HAVING SPECIAL FIRE PERFORMANCE - PART 1: GENERAL REQUIREMENTS
I.S. EN 50525-3-41:2011 ELECTRIC CABLES - LOW VOLTAGE ENERGY CABLES OF RATED VOLTAGES UP TO AND INCLUDING 450/750 V (U[0]/U) - PART 3-41: CABLES WITH SPECIAL FIRE PERFORMANCE - SINGLE CORE NON-SHEATHED CABLES WITH HALOGEN-FREE CROSSLINKED INSULATION, AND LOW EMISSION OF SMOKE
I.S. EN 50290-2-24:2002 COMMUNICATION CABLES - PART 2-24: COMMON DESIGN RULES AND CONSTRUCTION - PE SHEATHING
I.S. EN 50525-2-51:2011 ELECTRIC CABLES - LOW VOLTAGE ENERGY CABLES OF RATED VOLTAGES UP TO AND INCLUDING 450/750 V (U[0]/U) - PART 2-51: CABLES FOR GENERAL APPLICATIONS - OIL RESISTANT CONTROL CABLES WITH THERMOPLASTIC PVC INSULATION
IEC 62012-1:2002 Multicore and symmetrical pair/quad cables for digital communications to be used in harsh environments - Part 1: Generic specification
EN 50306-2:2002 Railway applications - Railway rolling stock cables having special fire performance - Thin wall - Part 2: Single core cables
EN 60794-2-50 : 2008 OPTICAL FIBRE CABLES - PART 2-50: INDOOR CABLES - FAMILY SPECIFICATION FOR SIMPLEX AND DUPLEX CABLES FOR USE IN TERMINATED CABLE ASSEMBLIES
UNE-EN 50525-2-41:2012 Electric cables - Low voltage energy cables of rated voltages up to and including 450/750 V (Uo/U) -- Part 2-41: Cables for general applications - Single core cables with crosslinked silicone rubber insulation
IEC 60708:2005 Low-frequency cables with polyolefin insulation and moisture barrier polyolefin sheath
EN 50305:2002 Railway applications - Railway rolling stock cables having special fire performance - Test methods
IEC 60794-2-42:2008 Optical fibre cables - Part 2-42: Indoor optical fibre cables - Product specification for simplex and duplex cables with A4 fibres
EN 50306-3:2002 Railway applications - Railway rolling stock cables having special fire performance - Thin wall - Part 3: Single core and multicore cables (pairs, triples and quads) screened and thin wall sheathed
UNE-EN 50525-2-31:2012 Electric cables - Low voltage energy cables of rated voltages up to and including 450/750 V (Uo/U) -- Part 2-31: Cables for general applications - Single core non-sheathed cables with thermoplastic PVC insulation
EN 50306-4:2002 Railway applications - Railway rolling stock cables having special fire performance - Thin wall - Part 4: Multicore and multipair cables standard wall sheathed
UNE-EN 50525-2-82:2012 Electric cables - Low voltage energy cables of rated voltages up to and including 450/750 V (Uo/U) - Part 2-82: Cables for general applications - Cables with crosslinked elastomeric insulation for decorative chains
EN 50525-2-83:2011 Electric cables - Low voltage energy cables of rated voltages up to and including 450/750 V (U0/U) - Part 2-83: Cables for general applications - Multicore cables with crosslinked silicone rubber insulation
EN 50363-3 : 2005 AMD 1 2011 INSULATING, SHEATHING AND COVERING MATERIALS FOR LOW VOLTAGE ENERGY CABLES - PART 3: PVC INSULATING COMPOUNDS
EN 50363-1:2005 Insulating, sheathing and covering materials for low voltage energy cables - Part 1: Cross-linked elastomeric insulating compounds
EN 50525-2-41:2011 Electric cables - Low voltage energy cables of rated voltages up to and including 450/750 V (U0/U) - Part 2-41: Cables for general applications - Single core cables with crosslinked silicone rubber insulation
PREN 50525-2-81 : DRAFT 2008 ELECTRIC CABLES - LOW VOLTAGE ENERGY CABLES OF RATED VOLTAGES UP TO AND INCLUDING 450/750 V - PART 2-81: CABLES FOR GENERAL APPLICATIONS - CABLES WITH CROSSLINKED ELASTOMERIC COVERING FOR ARC WELDING
PREN 50525-3-41 : DRAFT 2008 ELECTRIC CABLES - LOW VOLTAGE ENERGY CABLES OF RATED VOLTAGES UP TO AND INCLUDING 450/750 V - PART 3-41: CABLES WITH SPECIAL FIRE PERFORMANCE - SINGLE CORE NON-SHEATHED CABLES WITH HALOGEN-FREE CROSSLINKED INSULATION, AND LOW EMISSION OF SMOKE
04/30114758 DC : 0 IEC 60092-350 ED.3 - ELECTRICAL INSTALLATION IN SHIP - PART 350: SHIPBOARD POWER CABLES - GENERAL CONSTRUCTION AND TEST REQUIREMENTS
03/316192 DC : DRAFT SEP 2003 IEC 60708-1 ED 2 - LOW-FREQUENCY CABLES WITH POLYOLEFIN INSULATION AND MOISTURE BARRIER POLYOLEFIN SHEATH - PART 1: GENERAL DESIGN DETAILS AND REQUIREMENTS
UNE-EN 50525-3-41:2012 Electric cables - Low voltage energy cables of rated voltages up to and including 450/750 V (Uo/U) - Part 3-41: Cables with special fire performance - Single core non-sheathed cables with halogen-free crosslinked insulation, and low emission of smoke
08/30188783 DC : 0 BS EN 50525-2-21 - ELECTRIC CABLES - LOW VOLTAGE ENERGY CABLES OF RATED VOLTAGES UP TO AND INCLUDING 450/750 V - PART 2-21: CABLES FOR GENERAL APPLICATIONS - FLEXIBLE CABLES WITH CROSSLINKED ELASTOMERIC INSULATION
BS EN 60811-505:2012 Electric and optical fibre cables. Test methods for non-metallic materials Mechanical tests. Elongation at low temperature for insulations and sheaths
BS EN 50525-2-71:2011 Electric cables. Low voltage energy cables of rated voltages up to and including 450/750 V (U0/U) Cables for general applications. Flat tinsel cables (cords) with thermoplastic PVC insulation
BS EN 50525-2-72:2011 Electric cables. Low voltage energy cables of rated voltages up to and including 450/750 V (U0/U) Cables for general applications. Flat divisible cables (cords) with thermoplastic PVC insulation
I.S. EN 60794-2-42:2008 OPTICAL FIBRE CABLES - PART 2-42: INDOOR OPTICAL FIBRE CABLES - PRODUCT SPECIFICATION FOR SIMPLEX AND DUPLEX CABLES WITH A4 FIBRES
BS EN 61230:2008 Live working. Portable equipment for earthing or earthing and short-circuiting
PREN 50525-3-31 : DRAFT 2008 ELECTRIC CABLES - LOW VOLTAGE ENERGY CABLES OF RATED VOLTAGES UP TO AND INCLUDING 450/750 V - PART 3-31: CABLES WITH SPECIAL FIRE PERFORMANCE - SINGLE CORE NON-SHEATHED CABLES WITH HALOGEN-FREE THERMOPLASTIC INSULATION, AND LOW EMISSION OF SMOKE
BS EN 50290-2-30:2002 Communication cables. Common design rules and construction Poly(tetrafluoroethylene-hexafluoropropylene) (FEP) insulation and sheathing
08/30188813 DC : 0 BS EN 50525-2-72 - ELECTRIC CABLES - LOW VOLTAGE ENERGY CABLES OF RATED VOLTAGES UP TO AND INCLUDING 450/750 V - PART 2-72: CABLES FOR GENERAL APPLICATIONS - FLAT DIVISIBLE CABLES (CORDS) WITH THERMOPLASTIC PVC INSULATION
UNE-EN 60811-504:2012 Electric and optical fibre cables - Test methods for non-metallic materials - Part 504: Mechanical tests - Bending tests at low temperature for insulation and sheaths
05/30136253 DC : 0 EN 50264-2-1 - RAILWAY APPLICATIONS - RAILWAY ROLLING STOCK POWER AND CONTROL CABLES HAVING SPECIAL FIRE PERFORMANCE - PART 2-1: CABLES WITH CROSSLINKED ELASTOMERIC INSULATION - SINGLE CORE CABLES
08/30188839 DC : 0 BS EN 50525-3-31 - ELECTRIC CABLES - LOW VOLTAGE ENERGY CABLES OF RATED VOLTAGES UP TO AND INCLUDING 450/750 V - PART 3-31: CABLES WITH SPECIAL FIRE PERFORMANCE - SINGLE CORE NON-SHEATHED CABLES WITH HALOGEN-FREE THERMOPLASTIC INSULATION, AND LOW EMISSION OF SMOKE
05/30139161 DC : DRAFT SEP 2005 IEC 60794-2-42 - OPTICAL FIBRE CABLES - PART 2-42: INDOOR OPTICAL FIBRE CABLES - PRODUCT SPECIFICATION FOR SIMPLEX AND DUPLEX CABLES WITH A4 FIBRES
03/318201 DC : DRAFT NOV 2003 IEC 60502-2, ED.2 - POWER CABLES WITH EXTRUDED INSULATION AND THEIR ACCESSORIES FOR RATED VOLTAGES FROM 1 KV (UM = 1,2 KV) UP TO 30 KV (UM = 36 KV) - PART 2: CABLES FOR RATED VOLTAGES FROM 6 KV (UM = 7,2 KV) UP TO 30 KV (UM = 36 KV)
NF EN 50290-2-24 : 2002 AMD 1 2009 COMMUNICATION CABLES - PART 2-24: COMMON DESIGN RULES AND CONSTRUCTION - PE SHEATHING
BS EN 62012-1:2002 Multicore and symmetrical pair/quad cables for digital communications to be used in harsh environments Generic specification
BS EN 50306-3:2002 Railway applications. Railway rolling stock cables having special fire performance. Thin wall Single core and multicore cables (pairs, triples and quads) screened and thin wall sheathed
NF EN 50382-1 : 2008 AMD 1 2013 RAILWAY APPLICATIONS - RAILWAY ROLLING STOCK HIGH TEMPERATURE POWER CABLES HAVING SPECIAL FIRE PERFORMANCE - PART 1: GENERAL REQUIREMENTS
08/30188804 DC : 0 BS EN 50525-2-51 - ELECTRIC CABLES - LOW VOLTAGE ENERGY CABLES OF RATED VOLTAGES UP TO AND INCLUDING 450/750 V - PART 2-51: CABLES FOR GENERAL APPLICATIONS - OIL RESISTANT CONTROL CABLES WITH THERMOPLASTIC PVC INSULATION
UNE-EN 50264-2-2:2010 Railway applications - Railway rolling stock power and control cables having special fire performance -- Part 2-2: Cables with crosslinked elastomeric insulation - Multicore cables
NF EN 50264-3-2 : 2008 RAILWAY APPLICATIONS - RAILWAY ROLLING STOCK POWER AND CONTROL CABLES HAVING SPECIAL FIRE PERFORMANCE - PART 3-2: CABLES WITH CROSSLINKED ELASTOMERIC INSULATION WITH REDUCED DIMENSIONS - MULTICORE CABLES
BS EN 61138:1998 Cables for portable earthing and short-circuiting equipment
UNE-EN 50525-2-21:2012 Electric cables - Low voltage energy cables of rated voltages up to and including 450/750 V (Uo/U) -- Part 2-21: Cables for general applications - Flexible cables with crosslinked elastomeric insulation
UNE-EN 61230:2011 Live working - Portable equipment for earthing or earthing and short-circuiting
I.S. EN 50264-2-2:2008 RAILWAY APPLICATIONS - RAILWAY ROLLING STOCK POWER AND CONTROL CABLES HAVING SPECIAL FIRE PERFORMANCE - PART 2-2: CABLES WITH CROSSLINKED ELASTOMERIC INSULATION - MULTICORE CABLES
I.S. EN 50363-8:2005 INSULATING, SHEATHING AND COVERING MATERIALS FOR LOW VOLTAGE ENERGY CABLES - PART 8: HALOGEN-FREE, THERMOPLASTIC SHEATHING COMPOUNDS
CEI EN 50525-2-31 : 2012 ELECTRIC CABLES - LOW VOLTAGE ENERGY CABLES OF RATED VOLTAGES UP TO AND INCLUDING 450/750 V (U[0]/U) - PART 2-31: CABLES FOR GENERAL APPLICATIONS - SINGLE CORE NON-SHEATHED CABLES WITH THERMOPLASTIC PVC INSULATION
I.S. EN 50290-2-27:2002 COMMUNICATION CABLES - PART 2-27: COMMON DESIGN RULES AND CONSTRUCTION - HALOGEN FREE FLAME RETARDANT THERMOPLASTIC SHEATHING COMPOUNDS
NF EN 50306-1 : 2003 RAILWAY APPLICATIONS - RAILWAY ROLLING STOCK CABLES HAVING SPECIAL FIRE PERFORMANCE - THIN WALL - PART 1: GENERAL REQUIREMENTS
NF EN 50264-2-1 : 2008 RAILWAY APPLICATIONS - RAILWAY ROLLING STOCK POWER AND CONTROL CABLES HAVING SPECIAL FIRE PERFORMANCE - PART 2-1: CABLES WITH CROSSLINKED ELASTOMERIC INSULATION - SINGLE CORE CABLES
I.S. EN 50525-2-41:2011 ELECTRIC CABLES - LOW VOLTAGE ENERGY CABLES OF RATED VOLTAGES UP TO AND INCLUDING 450/750 V (U[0]/U) - PART 2-41: CABLES FOR GENERAL APPLICATIONS - SINGLE CORE CABLES WITH CROSSLINKED SILICONE RUBBER INSULATION
PREN 50525-3-21 : DRAFT 2008 ELECTRIC CABLES - LOW VOLTAGE ENERGY CABLES OF RATED VOLTAGES UP TO AND INCLUDING 450/750 V - PART 3-21: CABLES WITH SPECIAL FIRE PERFORMANCE - FLEXIBLE CABLES WITH HALOGEN-FREE CROSSLINKED INSULATION, AND LOW EMISSION OF SMOKE
UNE-EN 50363-0:2011 Insulating, sheathing and covering materials for low-voltage energy cables -- Part 0: General introduction
UNE-EN 50525-2-51:2012 Electric cables - Low voltage energy cables of rated voltages up to and including 450/750 V (Uo/U) -- Part 2-51: Cables for general applications - Oil resistant control cables with thermoplastic PVC insulation
IEC 60502-1:2004+AMD1:2009 CSV Power cables with extruded insulation and their accessories for rated voltages from 1 kV (<em>U</em><sub>m</sub> = 1,2 kV) up to 30 kV(<em>U</em><sub>m</sub> = 36 kV) - Part 1: Cables for rated voltages of 1 kV (<em>U</em><sub>m</sub> = 1,2 kV) and 3 kV (<em>U</em><sub>m</sub> = 3,6 kV)
I.S. EN 50290-2-30:2002 COMMUNICATION CABLES - PART 2-30: COMMON DESIGN RULES AND CONSTRUCTION - POLY(TETRAFLUOROETHYLENE-HEXAFLUOROPROPYLENE) (FEP) INSULATION AND SHEATHING
I.S. EN 50525-2-21:2011 ELECTRIC CABLES - LOW VOLTAGE ENERGY CABLES OF RATED VOLTAGES UP TO AND INCLUDING 450/750 V (U[0]/U) - PART 2-21: CABLES FOR GENERAL APPLICATIONS - FLEXIBLE CABLES WITH CROSSLINKED ELASTOMERIC INSULATION
IEC 61156-1:2007+AMD1:2009 CSV Multicore and symmetrical pair/quad cables for digital communications - Part 1: Generic specification
IEC 60794-2-30:2008 Optical fibre cables - Part 2-30: Indoor cables - Family specification for ribbon cables
IEC 60245-1:2003+AMD1:2007 CSV Rubber insulated cables - Rated voltages up to and including 450/750 V - Part 1: General requirements
I.S. EN 50525-2-71:2011 ELECTRIC CABLES - LOW VOLTAGE ENERGY CABLES OF RATED VOLTAGES UP TO AND INCLUDING 450/750 V (U[0]/U) - PART 2-71: CABLES FOR GENERAL APPLICATIONS - FLAT TINSEL CABLES (CORDS) WITH THERMOPLASTIC PVC INSULATION
EN 60335-2-14:2006/A12:2016 HOUSEHOLD AND SIMILAR ELECTRICAL APPLIANCES - SAFETY - PART 2-14: PARTICULAR REQUIREMENTS FOR KITCHEN MACHINES (IEC 60335-2-14:2006, MODIFIED)
EN 50363-4-2:2005 Insulating, sheathing and covering materials for low voltage energy cables - Part 4-2: PVC covering compounds
EN 50363-2-2:2005 Insulating, sheathing and covering materials for low voltage energy cables - Part 2-2: Cross-linked elastomeric covering compounds
EN 50525-2-12:2011 Electric cables - Low voltage energy cables of rated voltages up to and including 450/750 V (Uo/U) - Part 2-12: Cables for general applications - Cables with thermoplastic PVC insulation for extensible leads
EN 60811-504:2012 Electric and optical fibre cables - Test methods for non-metallic materials - Part 504: Mechanical tests - Bending tests at low temperature for insulation and sheaths
EN 50363-10-2 : 2005 Insulating, sheathing and covering materials for low voltage energy cables - Part 10-2: Miscellaneous sheathing compounds - Thermoplastic polyurethane
EN 50363-0:2011 Insulating, sheathing and covering materials for low-voltage energy cables - Part 0: General introduction
EN 50290-2-30:2002 Communication cables - Part 2-30: Common design rules and construction - Poly(tetrafluoroethylene-hexafluoropropylene) (FEP) insulation and sheathing
EN 50525-2-42:2011 Electric cables - Low voltage energy cables of rated voltages up to and including 450/750 V (U0/U) - Part 2-42: Cables for general applications - Single core non-sheathed cables with crosslinked EVA insulation
EN 50264-2-2:2008 Railway applications - Railway rolling stock power and control cables having special fire performance - Part 2-2: Cables with crosslinked elastomeric insulation - Multicore cables
EN 50264-3-1:2008 Railway applications - Railway rolling stock power and control cables having special fire performance - Part 3-1: Cables with crosslinked elastomeric insulation with reduced dimensions - Single core cables
EN 62012-1:2002 Multicore and symmetrical pair/quad cables for digital communications to be used in harsh environments - Part 1: Generic specification
EN 50382-2:2008/A1:2013 RAILWAY APPLICATIONS - RAILWAY ROLLING STOCK HIGH TEMPERATURE POWER CABLES HAVING SPECIAL FIRE PERFORMANCE - PART 2: SINGLE CORE SILICONE RUBBER INSULATED CABLES FOR 120 DEGREES C OR 150 DEGREES C
EN 60794-2-42:2008 Optical fibre cables - Part 2-42: Indoor optical fibre cables - Product specification for simplex and duplex cables with A4 fibres
EN 50363-5 : 2005 AMD 1 2011 INSULATING, SHEATHING AND COVERING MATERIALS FOR LOW VOLTAGE ENERGY CABLES - PART 5: HALOGEN-FREE, CROSS-LINKED INSULATING COMPOUNDS
EN 60708:2005/AC:2016-08 LOW-FREQUENCY CABLES WITH POLYOLEFIN INSULATION AND MOISTURE BARRIER POLYOLEFIN SHEATH
EN 50525-2-82:2011 Electric cables - Low voltage energy cables of rated voltages up to and including 450/750 V (U0/U) - Part 2-82: Cables for general applications - Cables with crosslinked elastomeric insulation for decorative chains
EN 50363-4-1:2005 Insulating, sheathing and covering materials for low voltage energy cables - Part 4-1: PVC sheathing compounds
EN 50525-3-21:2011/AC:2013 ELECTRIC CABLES - LOW VOLTAGE ENERGY CABLES OF RATED VOLTAGES UP TO AND INCLUDING 450/750 V (U[0]/U) - PART 3-21: CABLES WITH SPECIAL FIRE PERFORMANCE - FLEXIBLE CABLES WITH HALOGEN-FREE CROSSLINKED INSULATION, AND LOW EMISSION OF SMOKE
EN 50525-3-41:2011 Electric cables - Low voltage energy cables of rated voltages up to and including 450/750 V (U0/U) - Part 3-41: Cables with special fire performance - Single core non-sheathed cables with halogen-free crosslinked insulation, and low emission of smoke
EN 50525-2-11:2011 Electric cables - Low voltage energy cables of rated voltages up to and including 450/750 V (Uo/U) - Part 2-11: Cables for general applications - Flexible cables with thermoplastic PVC insulation
EN 50525-2-21:2011/AC:2013 ELECTRIC CABLES - LOW VOLTAGE ENERGY CABLES OF RATED VOLTAGES UP TO AND INCLUDING 450/750 V (U[0]/U) - PART 2-21: CABLES FOR GENERAL APPLICATIONS - FLEXIBLE CABLES WITH CROSSLINKED ELASTOMERIC INSULATION
EN 50290-2-21:2001/A1:2007/AC:2016 COMMUNICATION CABLES - PART 2-21: COMMON DESIGN RULES AND CONSTRUCTION - PVC INSULATING COMPOUNDS

AS/NZS IEC 60227.5:2019 Polyvinyl chloride insulated cables of rated voltages up to and including 450/750 V Flexible cables (cords)
AS/NZS IEC 60245.4:2020 Rubber insulated cables - Rated voltages up to and including 450/750 V Cords and flexible cables
HD 505.1.1 : 200S3 COMMON TEST METHODS FOR INSULATING & SHEATHING MATERIALS OF ELECTRIC CABLES: METHODS FOR GENERAL APPLICATION: MEASUREMENT OF THICKNESS OVERALL DIMENSIONS TESTS FOR DETERMINING THE MECHANICAL PROPERTIES
IEC 60538A:1980 First supplement
IEC 60811-1-1:1993+AMD1:2001 CSV Common test methods for insulating and sheathing materials of electric cables and optical cables - Part 1-1: Methods for general application - Measurement of thickness and overall dimensions - Tests for determining the mechanical properties

View more information
US$93.00
Excluding Tax where applicable

Access your standards online with a subscription

Features

  • Simple online access to standards, technical information and regulations.

  • Critical updates of standards and customisable alerts and notifications.

  • Multi-user online standards collection: secure, flexible and cost effective.