IEC 61262-4:1994

Current
Current

The latest, up-to-date edition.

Medical electrical equipment - Characteristics of electro-optical X-ray image intensifiers - Part 4: Determination of the image distortion
Available format(s)

Hardcopy , PDF , PDF 3 Users , PDF 5 Users , PDF 9 Users

Language(s)

English - French, Spanish, Castilian

Published date

07-29-1994

Foreword
Introduction
Clause
1 Scope
2 Normative reference
3 Terminology
   3.1 Definitions
   3.2 Degree of requirements and reading instructions
4 Requirements
   4.1 Test set-up
   4.2 X-RAY IMAGE INTENSIFIER - Operating conditions
   4.3 Input radiation
   4.4 TEST DEVICE
   4.5 Measurement equipment
5 Determination of the IMAGE DISTORTION
   5.1 Not used
   5.2 Not used
   5.3 Not used
   5.4 Determination
        5.4.1 Determination of the DIFFERENTIAL RADIAL
               IMAGE DISTORTION
        5.4.2 Determination of the INTEGRAL IMAGE
               DISTORTION
6 Presentation of the IMAGE DISTORTION
7 Statement of compliance
Figure 1 - Suggested TEST DEVICE for the determination
           of the IMAGE DISTORTION
Annex A - Terminology - Index of terms

Applies to electro-optical X-ray image intensifiers for medical use, as components of diagnostic X-ray equipment. Describes a method of determining the image distortion of X-ray image intensifiers.Cancels and replaces IEC 60858.

Committee
TC 62/SC 62B
DevelopmentNote
Supersedes IEC 858 (03/2001) Also numbered as BS EN 61262-4 (11/2005) Stability Date: 2020. (10/2012)
DocumentType
Standard
Pages
23
PublisherName
International Electrotechnical Committee
Status
Current
Supersedes

Standards Relationship
NF EN 61262-4 : 1994 Identical
NEN 11262-4 : 1994 Identical
I.S. EN 61262-4:1995 Identical
PN EN 61262-4 : 2002 Identical
SN EN 61262-4 : 1994 Identical
AS/NZS 4356.4:1996 Identical
UNE-EN 61262-4:1996 Identical
CEI EN 61262-4 : 1998 Identical
EN 61262-4:1994 Identical
DIN EN 61262-4:1995-09 Identical

06/30107360 DC : 0 IEC 60601-1-3 - MEDICAL ELECTRICAL EQUIPMENT - PART 1-3: GENERAL REQUIREMENTS FOR BASIC SAFETY AND ESSENTIAL PERFORMANCE - COLLATERAL STANDARD - RADIATION PROTECTION IN DIAGNOSTIC X-RAY EQUIPMENT
CEI EN 61262-7 : 1997 MEDICAL ELECTRICAL EQUIPMENT - CHARACTERISTICS OF ELECTRO-OPTICAL X-RAY IMAGE INTENSIFIERS - PART 7: DETERMINATION OF THE MODULATION TRANSFER FUNCTION
IEC TR 60788:2004 Medical electrical equipment - Glossary of defined terms
PD IEC TR 60788:2004 Medical electrical equipment. Glossary of defined terms
IEC 61262-7:1995 Medical electrical equipment - Characteristics of electro-optical X-ray image intensifiers - Part 7: Determination of the modulation transfer function
I.S. EN 61262-7:1997 MEDICAL ELECTRICAL EQUIPMENT - CHARACTERISTICS OF ELECTRO-OPTICAL X-RAY IMAGE INTENSIFIERS - PART 7: DETERMINATION OF THE MODULATION TRANSFER FUNCTION
EN 61262-7:1995 Medical electrical equipment - Characteristics of electro-optical X-ray image intensifiers - Part 7: Determination of the modulation transfer function

IEC TR 60788:2004 Medical electrical equipment - Glossary of defined terms

View more information
US$46.00
Excluding Tax where applicable

Access your standards online with a subscription

Features

  • Simple online access to standards, technical information and regulations.

  • Critical updates of standards and customisable alerts and notifications.

  • Multi-user online standards collection: secure, flexible and cost effective.