IEC 61558-2-19:2000

Withdrawn

Withdrawn

A Withdrawn Standard is one, which is removed from sale, and its unique number can no longer be used. The Standard can be withdrawn and not replaced, or it can be withdrawn and replaced by a Standard with a different number.

Safety of power transformers, power supply units and similar devices - Part 2-19: Particular requirements for perturbation attenuation transformers

Available format(s)

Hardcopy , PDF , PDF 3 Users , PDF 5 Users , PDF 9 Users

Withdrawn date

03-12-2009

Language(s)

English - French, Spanish, Castilian

Published date

06-30-2000

FOREWORD
1 Scope
2 Normative references
3 Definitions
4 General requirements
5 General notes on tests
6 Ratings
7 Classification
8 Marking and other information
9 Protection against accessibility to hazardous live
      parts
10 Change of input voltage setting
11 Output voltage and output current under load
12 No-load output voltage
13 Short-circuit voltage
14 Heating
15 Short-circuit and overload protection
16 Mechanical strength
17 Protection against harmful ingress of dust, solid
      objects and moisture
18 Insulation resistance and electric strength
19 Construction
20 Components
21 Internal wiring
22 Supply connection and other external flexible cables
      or cords
23 Terminals for external conductors
24 Provision for protective earthing
25 Screws and connections
26 Creepage distances, clearances and distances through
      insulation
27 Resistance to heat, abnormal heat, fire and tracking
28 Resistance to rusting
Figure 101 - Protection of the output circuit in case of
             short circuit
Table 101 - Maximum disconnecting time

This International Standard deals with all aspects of safety such as electrical, thermal and mechanical.This part 2-19 of IEC 61558 applies to stationary or portable, single-phase or poly-phase, air-cooled (natural or forced), independent or associated, isolating or safety isolating transformers, having a rated supply voltage not exceeding 1 000 V a.c., a rated frequency not exceeding 500 Hz, a rated output not exceeding 10 kVA. Perturbation attenuation transformers are intended to the supply of office machines and the like and have a mid-point lead out in the output circuit in order to attenuate mains borne disturbances.In addition, double or reinforced insulation between circuits required by the installation rules or by the appliance specification is fulfilled by using this transformer.This part 2-19 is intended to be used in conjunction with IEC 61558-1It has the status of a group safety publication in accordance with IEC Guide 104.

DevelopmentNote
Also numbered as BS EN 61558-2-19. (05/2001) Supersedes IEC 60742 (07/2004)
DocumentType
Standard
Pages
29
PublisherName
International Electrotechnical Committee
Status
Withdrawn

View more information
US$93.00
Excluding Tax where applicable

Access your standards online with a subscription

Features

  • Simple online access to standards, technical information and regulations.

  • Critical updates of standards and customisable alerts and notifications.

  • Multi-user online standards collection: secure, flexible and cost effective.