FOREWORD
INTRODUCTION
1 Scope and object
2 Normative references
3 Terminology and definitions
4 General performance requirements for measurement of
  PRACTICAL PEAK VOLTAGE measurements
  4.1 Quantity to be measured
  4.2 Limits of PERFORMANCE CHARACTERISTICS
  4.3 LIMITS OF VARIATION for effects of INFLUENCE
      QUANTITIES
  4.4 Performance test procedures
5 Special instrumental requirements and marking
  5.1 Requirements for the complete instruments
  5.2 General
  5.3 Display
  5.4 Range of measurement
  5.5 Connectors and cables
6 ACCOMPANYING DOCUMENTS
  6.1 General
  6.2 Information provided
  6.3 Instrument description
  6.4 Detector
  6.5 Delay time
  6.6 Measurement window
  6.7 Data outlet
  6.8 Transport and storage
Annex A (informative) Recommended performance criteria
        for the invasive divider
Annex B (informative) Additional information on PRACTICAL
        PEAK VOLTAGE
Annex C (informative) Glossary of defined terms

Specifies the performance requirements of instruments as used in the non-invasive measurement of X-ray tube voltage up to 150 kV and the relevant compliance tests. Describes the method for calibration and gives guidance for estimating the uncertainty in measurements performed under conditions different from those during calibration. This standard is not concerned with the safety aspect of such instruments. The requirements for electrical safety applying to them are contained in IEC 61010-1. This consolidated version consists of the first edition (2002) and its amendment 1 (2008). Therefore, no need to order amendment in addition to this publication.

Committee
TC 62/SC 62C
DevelopmentNote
Stability Date: 2018. (09/2017)
DocumentType
Standard
Pages
32
PublisherName
International Electrotechnical Committee
Status
Superseded
SupersededBy

BS EN 62467-1:2015 Medical electrical equipment. Dosimetric instruments as used in brachytherapy Instruments based on well-type ionization chambers
17/30362279 DC : 0 BS EN 61223-3-6 - EVALUATION AND ROUTINE TESTING IN MEDICAL IMAGING DEPARTMENTS - PART 3-6: ACCEPTANCE AND CONSTANCY TESTS - IMAGING PERFORMANCE OF MAMMOGRAPHIC TOMOSYNTHESIS MODE OF OPERATION OF MAMMOGRAPHIC X-RAY EQUIPMENT
BS EN 61223-3-2:2008 Evaluation and routine testing in medical imaging departments Acceptance tests. Imaging performance of mammographic X-ray equipment
EN 62467-1:2015 Medical electrical equipment - Dosimetric instruments as used in brachytherapy - Part 1: Instruments based on well-type ionization chambers
CEI EN 60731 : 2012 MEDICAL ELECTRICAL EQUIPMENT - DOSIMETERS WITH IONIZATION CHAMBERS AS USED IN RADIOTHERAPY
IEC TR 60788:2004 Medical electrical equipment - Glossary of defined terms
I.S. EN 61267:2006 MEDICAL DIAGNOSTIC X-RAY EQUIPMENT - RADIATION CONDITIONS FOR USE IN THE DETERMINATION OF CHARACTERISTICS
BS ISO 16142-1:2016 Medical devices. Recognized essential principles of safety and performance of medical devices General essential principles and additional specific essential principles for all non-IVD medical devices and guidance on the selection of standards
ISO 16142-1:2016 Medical devices — Recognized essential principles of safety and performance of medical devices — Part 1: General essential principles and additional specific essential principles for all non-IVD medical devices and guidance on the selection of standards
BS EN 60731:2012 Medical electrical equipment. Dosimeters with ionization chambers as used in radiotherapy
I.S. EN 61223-3-2:2008 EVALUATION AND ROUTINE TESTING IN MEDICAL IMAGING DEPARTMENTS - PART 3-2: ACCEPTANCE TESTS - IMAGING PERFORMANCE OF MAMMOGRAPHIC X-RAY EQUIPMENT
IEC 61223-3-2:2007 Evaluation and routine testing in medical imaging departments - Part 3-2: Acceptance tests - Imaging performance of mammographic X-ray equipment
PD IEC TR 60788:2004 Medical electrical equipment. Glossary of defined terms
09/30194820 DC : 0 BS EN 60731 - MEDICAL ELECTRICAL EQUIPMENT - DOSIMETERS WITH IONIZATION CHAMBERS AS USED IN RADIOTHERAPY
I.S. EN 60731:2012 MEDICAL ELECTRICAL EQUIPMENT - DOSIMETERS WITH IONIZATION CHAMBERS AS USED IN RADIOTHERAPY (IEC 60731:2011 (EQV))
BS EN 61267:2006 Medical diagnostic X-ray equipment. Radiation conditions for use in the determination of characteristics
IEC 61267:2005 Medical diagnostic X-ray equipment - Radiation conditions for use in the determination of characteristics
CEI EN 61267 : 2006 MEDICAL DIAGNOSTIC X-RAY EQUIPMENT - RADIATION CONDITIONS FOR USE IN THE DETERMINATION OF CHARACTERISTICS
I.S. EN 62467-1:2015 MEDICAL ELECTRICAL EQUIPMENT - DOSIMETRIC INSTRUMENTS AS USED IN BRACHYTHERAPY - PART 1: INSTRUMENTS BASED ON WELL-TYPE IONIZATION CHAMBERS
IEC 62467-1:2009 Medical electrical equipment - Dosimetric instruments as used in brachytherapy - Part 1: Instruments based on well-type ionization chambers
EN 61223-3-2:2008 Evaluation and routine testing in medical imaging departments - Part 3-2: Acceptance tests - Imaging performance of mammographic X-ray equipment
EN 61267:2006 Medical diagnostic X-ray equipment - Radiation conditions for use in the determination of characteristics
EN 60731:2012 Medical electrical equipment - Dosimeters with ionization chambers as used in radiotherapy

IEC 61000-4-4 : 3.0EN+(REDLINE+VERSION) ELECTROMAGNETIC COMPATIBILITY (EMC) - PART 4-4: TESTING AND MEASUREMENT TECHNIQUES - ELECTRICAL FAST TRANSIENT/BURST IMMUNITY TEST
IEC 61187:1993 Electrical and electronic measuring equipment - Documentation
IEC 61000-4-11:2004+AMD1:2017 CSV Electromagnetic compatibility (EMC) - Part 4-11: Testing and measurement techniques - Voltage dips, short interruptions and voltage variations immunity tests
IEC TR 60788:2004 Medical electrical equipment - Glossary of defined terms
IEC 61000-4-4:2012 RLV Electromagnetic compatibility (EMC) - Part 4-4: Testing and measurement techniques - Electrical fast transient/burst immunity test
IEC 61000-4-6 : 4.0 ELECTROMAGNETIC COMPATIBILITY (EMC) - PART 4-6: TESTING AND MEASUREMENT TECHNIQUES - IMMUNITY TO CONDUCTED DISTURBANCES, INDUCED BY RADIO-FREQUENCY FIELDS
IEC 61000-4-6:2013 Electromagnetic compatibility (EMC) - Part 4-6: Testing and measurement techniques - Immunity to conducted disturbances, induced by radio-frequency fields
ISO/IEC Guide 99:2007 International vocabulary of metrology Basic and general concepts and associated terms (VIM)
IEC 61000-4-2:2008 Electromagnetic compatibility (EMC) - Part 4-2: Testing and measurement techniques - Electrostatic discharge immunity test
IEC 61000-4-3:2006+AMD1:2007+AMD2:2010 CSV Electromagnetic compatibility (EMC) - Part 4-3: Testing and measurement techniques - Radiated, radio-frequency, electromagnetic field immunity test
ISO 7000:2014 Graphical symbols for use on equipment Registered symbols
IEC 61010-1:2010+AMD1:2016 CSV Safety requirements for electrical equipment for measurement, control, and laboratory use - Part 1: General requirements

View more information
US$389.00
Excluding Tax where applicable

Access your standards online with a subscription

Features

  • Simple online access to standards, technical information and regulations.

  • Critical updates of standards and customisable alerts and notifications.

  • Multi-user online standards collection: secure, flexible and cost effective.