FOREWORD
INTRODUCTION
1 General
   1.1 Scope
   1.2 Normative references
2 Definitions
3 Measuring principles
   3.1 Catalytic sensor
   3.2 Thermal conductivity sensor
   3.3 Electromagnetic radiation absorption sensor -
        usually infrared
   3.4 Semi-conductor sensor
   3.5 Electrochemical sensors
   3.6 Flame ionization detectors (FID)
4 Selection of apparatus
   4.1 General
   4.2 Selection criteria
   4.3 Miscellaneous factors affecting selection of
        apparatus
5 Behaviour of gas releases
   5.1 Nature of a release
   5.2 Outdoor sites and open structures
   5.3 Buildings and enclosures
   5.4 Environmental considerations
6 Installation of fixed gas detection apparatus
   6.1 Basic considerations for the installation of fixed
        systems
   6.2 Location of sensors
   6.3 Installation of sensors
   6.4 Timing of installation during construction operations
   6.5 Safety in fixed systems
   6.6 Environmental conditions
   6.7 Sample lines
   6.8 Access for calibration and maintenance
   6.9 Commissioning
   6.10 Operating instructions, plans and records
7 Use of portable and transportable flammable gas detection
   apparatus
   7.1 General
   7.2 Initial and periodic check procedures for portable
        and transportable instrumentation
   7.3 Guidance on the use of portable and transportable
        apparatus
8 Special precautions for fixed and portable apparatus
9 Maintenance, routine procedures and general
   administrative control
   9.1 General
   9.2 Operational checks
   9.3 Maintenance
   9.4 Sensors
   9.5 Flow systems
   9.6 Readout devices
   9.7 Alarms
   9.8 Workshop calibration test
   9.9 Routine tests and re-calibration procedures
   9.10 General administrative control
10 Training
Annex A (informative) Flammability limits (LFL and UFL) of
        certain flammable gases and vapours
Annex B (informative) Environmental and application
        check-list for flammable gas detectors (typical)
Annex C (informative) Instrument maintenance record for
        flammable gas detectors (typical)
Annex D (informative) Minimum environmental demands for
        IEC 61779-4 (group II 100 % LFL) and IEC 61779-5
        (group II 100 % (v/v) gas)

Gives guidance on the selection, installation, use and maintenance of electrically operated group II apparatus for the detection and measurement of flammable gases complying with the requirements of IEC 61779-1 to IEC 61779-5. For the purpose of this standard, flammable gases shall include flammable vapours. This standard applies only to group II apparatus intended for use in industrial and commercial safety applications, involving areas classified in accordance with IEC 60079-10.

DevelopmentNote
A BILINGUAL VERSION OF THIS STANDARD MAY BE ISSUED AT A LATER DATE (08/2000)
DocumentType
Standard
Pages
58
PublisherName
International Electrotechnical Committee
Status
Superseded
SupersededBy

Standards Relationship
SANS 61779-6 : 1999 AMD 1 2007 Identical
NEN EN 50073 : 1999 Identical

BS ISO 16110-1:2007 Hydrogen generators using fuel processing technologies Safety
06/30157092 DC : 0 ISO/DIS 21789 - GAS TURBINE APPLICATIONS - SAFETY
NF ISO 16110-1 : 2009 HYDROGEN GENERATORS USING FUEL PROCESSING TECHNOLOGIES - PART 1: SAFETY
05/30060689 DC : DRAFT JUN 2005 IEC 62282-3-1 - FUEL CELL TECHNOLOGIES - PART 3-1: STATIONARY FUEL CELL POWER PLANTS - SAFETY
IEC 62282-3-1:2007 Fuel cell technologies - Part 3-1: Stationary fuel cell power systems - Safety
EN 62282-3-1 : 2007 FUEL CELL TECHNOLOGIES - PART 3-1: STATIONARY FUEL CELL POWER SYSTEMS - SAFETY
EN 62282-3-3:2008 Fuel cell technologies - Part 3-3: Stationary fuel cell power systems - Installation
ISA TR12.13.03 : 2009 GUIDE FOR COMBUSTIBLE GAS DETECTION AS A METHOD OF PROTECTION
I.S. EN 62282-3-1:2007 FUEL CELL TECHNOLOGIES - PART 3-1: STATIONARY FUEL CELL POWER SYSTEMS - SAFETY
NF EN 62282-3-3 : 2008 FUEL CELL TECHNOLOGIES - PART 3-3: STATIONARY FUEL CELL POWER SYSTEMS - INSTALLATION
ISO 16110-1:2007 Hydrogen generators using fuel processing technologies Part 1: Safety
UNE-EN 62282-3-1:2011 Fuel cell technologies - Part 3-1: Stationary fuel cell power systems - Safety
BS EN 62282-3-1:2007 Fuel cell technologies Stationary fuel cell power systems. Safety
I.S. EN 62282-3-3:2008 FUEL CELL TECHNOLOGIES - PART 3-3: STATIONARY FUEL CELL POWER SYSTEMS - INSTALLATION
IEC 62282-3-3:2007 Fuel cell technologies - Part 3-3: Stationary fuel cell power systems - Installation
UNE-ISO 16110-1:2015 Hydrogen generators using fuel processing technologies -- Part 1: Safety
04/30089617 DC : DRAFT MARCH 2004
BS EN 62282-3-3:2008 Fuel cell technologies Stationary fuel cell power systems. Installation
API 14FZ : 2013 RECOMMENDED PRACTICE FOR DESIGN, INSTALLATION, AND MAINTENANCE OF ELECTRICAL SYSTEMS FOR FIXED AND FLOATING OFFSHORE PETROLEUM FACILITIES FOR UNCLASSIFIED AND CLASS 1, ZONE 0, ZONE 1, AND ZONE 2 LOCATIONS
API 500 : 2012 RECOMMENDED PRACTICE FOR CLASSIFICATION OF LOCATIONS FOR ELECTRICAL INSTALLATIONS AT PETROLEUM FACILITIES CLASSIFIED AS CLASS 1, DIVISION 1 AND DIVISION 2

IEC 60079-1:2014 RLV Explosive atmospheres - Part 1: Equipment protection by flameproof enclosures "d"
IEC 60079-10:2002 Electrical apparatus for explosive gas atmospheres - Part 10: Classification of hazardous areas
IEC TR 60079-20:1996 Electrical apparatus for explosive gas atmospheres - Part 20: Data for flammable gases and vapours, relating to the use of electrical apparatus
IEC 60079-19:2010+AMD1:2015 CSV Explosive atmospheres - Part 19: Equipment repair, overhaul and reclamation
IEC 60079-17:2013 Explosive atmospheres - Part 17: Electrical installations inspection and maintenance
IEC 60079-18:2014 RLV Explosive atmospheres - Part 18: Equipment protection by encapsulation “m”
IEC 61779-2:1998 Electrical apparatus for the detection and measurement of flammable gases - Part 2: Performance requirements for group I apparatus indicating a volume fraction up to 5 % methane in air
IEC TR 60079-16:1990 Electrical apparatus for explosive gas atmospheres. Part 16: Artificial ventilation for the protection of analyser(s) houses
IEC 60079-5:2015 RLV Explosive atmospheres - Part 5: Equipment protection by powder filling "q"
IEC 60050-426:2008 International Electrotechnical Vocabulary (IEV) - Part 426: Equipment for explosive atmospheres
IEC 60079-11:2011 Explosive atmospheres - Part 11: Equipment protection by intrinsic safety "i"
IEC 60079-3:1990 Electrical apparatus for explosive gas atmospheres - Part 3: Spark-test apparatus for intrinsically-safe circuits
IEC 61779-4:1998 Electrical apparatus for the detection and measurement of flammable gases - Part 4: Performance requirements for group II apparatus indicating up to 100% lower explosive limit
IEC 60079-6:2015 Explosive atmospheres - Part 6: Equipment protection by liquid immersion "o"
IEC 60079-0:2011 Explosive atmospheres - Part 0: Equipment - General requirements
IEC 60079-14:2013 Explosive atmospheres - Part 14: Electrical installations design, selection and erection
IEC 61779-3:1998 Electrical apparatus for the detection and measurement of flammable gases - Part 3: Performance requirements for group I apparatus indicating a volume fraction up to 100 % methane in air
IEC 61779-5:1998 Electrical apparatus for the detection and measurement of flammable gases - Part 5: Performance requirements for group II apparatus indicating a volume fraction up to 100 % gas
IEC TR 60079-12:1978 Electrical apparatus for explosive gas atmospheres - Part 12:Classification of mixtures of gases of vapours with air accordingto their maximum experimental safe gaps and minimum ignitingcurrents
IEC 61779-1:1998 Electrical apparatus for the detection and measurement of flammable gases - Part 1: General requirements and test methods
IEC 60079-15:2010 Explosive atmospheres - Part 15: Equipment protection by type of protection "n"
IEC 60079-13:2017 Explosive atmospheres - Part 13: Equipment protection by pressurized room "p" and artificially ventilated room "v"
IEC 60079-4A:1970 Electrical apparatus for explosive gas atmospheres - Part 4: Method of test for ignition temperature - First supplement. *Note.-This supplement applies also to the second edition of 1975

View more information
US$348.00
Excluding Tax where applicable

Access your standards online with a subscription

Features

  • Simple online access to standards, technical information and regulations.

  • Critical updates of standards and customisable alerts and notifications.

  • Multi-user online standards collection: secure, flexible and cost effective.