• There are no items in your cart

IEC 62271-103:2011

Superseded
Superseded

A superseded Standard is one, which is fully replaced by another Standard, which is a new edition of the same Standard.

View Superseded by
superseded

A superseded Standard is one, which is fully replaced by another Standard, which is a new edition of the same Standard.

High-voltage switchgear and controlgear - Part 103: Switches for rated voltages above 1 kV up to and including 52 kV
Available format(s)

Hardcopy , PDF , PDF 3 Users , PDF 5 Users , PDF 9 Users

Superseded date

12-31-2021

Published date

06-16-2011

FOREWORD
1 General
2 Normal and special service conditions
3 Terms and definitions
4 Ratings
5 Design and construction
6 Type tests
7 Routine tests
8 Guide to the selection of switchgear and controlgear
9 Information to be given with inquiries, tenders and orders
10 Transport, storage, installation, operation and maintenance
11 Safety
12 Influence of the product on the environment
Annex A (normative) - Tolerances on test quantities for type tests
Bibliography

IEC 62271-103:2011 is applicable to three-phase, alternating current switches and switch-disconnectors for their switching function, having making and breaking current ratings, for indoor and outdoor installations, for rated voltages above 1 kV up to and including 52 kV and for rated frequencies from 162/3 Hz up to and including 60 Hz. This standard is also applicable to single-pole switches used on three phase systems. This standard cancels and replaces the third edition of IEC 60265-1, published in 1998. It constitutes a technical revision. This edition includes the following significant technical changes with respect to IEC 60265-1:1998:
- the rated voltage of 52 kV is now included;
- the document is aligned with IEC 62271-1 and IEC 62271-100;
- addition of a test procedure for short-circuit making tests;
- introduction of notion of NSDD (non-sustained disruptive discharge) as defined in IEC 62271-1 and restrikes;
- new classes C1 and C2 for capacitive switching;
- new Annex A defining tolerances.
This publication is to be read in conjunction with IEC 62271-1:2007. The contents of the corrigendum of October 2013 have been included in this copy.

DevelopmentNote
To be read in conjunction with IEC 62271-1. Supersedes IEC 60265-1. (06/2011) Stability Date: 2020. (11/2017)
DocumentType
Standard
Pages
134
PublisherName
International Electrotechnical Committee
Status
Superseded
SupersededBy

BS EN 62271-107:2012 High-voltage switchgear and controlgear Alternating current fused circuit-switchers for rated voltages above 1 kV up to and including 52 kV
BS EN 62475:2010 High-current test techniques. Definitions and requirements for test currents and measuring systems
BS EN 62271-106:2011 High-voltage switchgear and controlgear Alternating current contactors, contactor-based controllers and motor-starters
I.S. EN 62271-106:2011 HIGH-VOLTAGE SWITCHGEAR AND CONTROLGEAR - PART 106: ALTERNATING CURRENT CONTACTORS, CONTACTOR-BASED CONTROLLERS AND MOTOR-STARTERS (IEC 62271-106:2011 (EQV))
17/30368300 DC : 0 BS EN 62271-107 ED.3.0 - HIGH-VOLTAGE SWITCHGEAR AND CONTROLGEAR - PART 107: ALTERNATING CURRENT FUSED CIRCUIT-SWITCHERS FOR RATED VOLTAGES ABOVE 1 KV UP TO AND INCLUDING 52 KV
CEI EN 62475 : 2011 HIGH-CURRENT TEST TECHNIQUES - DEFINITIONS AND REQUIREMENTS FOR TEST CURRENTS AND MEASURING SYSTEMS
PREN 50119 : DRAFT 2017 RAILWAY APPLICATIONS - FIXED INSTALLATIONS - ELECTRIC TRACTION OVERHEAD CONTACT LINES
I.S. EN 62271-105:2012 HIGH-VOLTAGE SWITCHGEAR AND CONTROLGEAR - PART 105: ALTERNATING CURRENT SWITCH-FUSE COMBINATIONS FOR RATED VOLTAGES ABOVE 1 KV UP TO AND INCLUDING 52 KV (IEC 62271-105:2012 (EQV))
I.S. EN 62271-200:2012 HIGH-VOLTAGE SWITCHGEAR AND CONTROLGEAR - PART 200: A.C. METAL-ENCLOSED SWITCHGEAR AND CONTROLGEAR FOR RATED VOLTAGES ABOVE 1 KV AND UP TO AND INCLUDING 52 KV (IEC 62271-200:2011 (EQV))
I.S. EN 62271-3:2015 HIGH-VOLTAGE SWITCHGEAR AND CONTROLGEAR - PART 3: DIGITAL INTERFACES BASED ON IEC 61850
EN 62271-3:2015 High-voltage switchgear and controlgear - Part 3: Digital interfaces based on IEC 61850
EN 62271-201:2014 High-voltage switchgear and controlgear - Part 201: AC solid-insulation enclosed switchgear and controlgear for rated voltages above 1 kV and up to and including 52 kV
NF EN 62271-107 : 2013 HIGH VOLTAGE SWITCHGEAR AND CONTROLGEAR - PART 107: ALTERNATING CURRENT FUSED CIRCUIT-SWITCHERS FOR RATED VOLTAGES ABOVE 1 KV UP TO AND INCLUDING 52 KV
EN 62271-105:2012 HIGH-VOLTAGE SWITCHGEAR AND CONTROLGEAR - PART 105: ALTERNATING CURRENT SWITCH-FUSE COMBINATIONS FOR RATED VOLTAGES ABOVE 1 KV UP TO AND INCLUDING 52 KV (IEC 62271-105:2012)
EN 62475 : 2010 HIGH-CURRENT TEST TECHNIQUES - DEFINITIONS AND REQUIREMENTS FOR TEST CURRENTS AND MEASURING SYSTEMS
CEI EN 62271-105 : 2014 HIGH-VOLTAGE SWITCHGEAR AND CONTROLGEAR - PART 105: ALTERNATING CURRENT SWITCH-FUSE COMBINATIONS FOR RATED VOLTAGES ABOVE 1 KV UP TO AND INCLUDING 52 KV
BS EN 62271-3:2015 High-voltage switchgear and controlgear Digital interfaces based on IEC 61850
UNE-EN 50152-2:2013 Railway applications - Fixed installations - Particular requirements for alternating current switchgear - Part 2: Disconnectors, earthing switches and switches with nominal voltage above 1 kV
17/30341013 DC : DRAFT AUG 2017 BS EN 50119 - RAILWAY APPLICATIONS - FIXED INSTALLATIONS - ELECTRIC TRACTION OVERHEAD CONTACT LINES
04/30092543 DC : DRAFT MAR 2004
BS EN 62271-200:2012 High-voltage switchgear and controlgear AC metal-enclosed switchgear and controlgear for rated voltages above 1 kV and up to and including 52 kV
CEI EN 62271-201 : 2015 HIGH-VOLTAGE SWITCHGEAR AND CONTROLGEAR - PART 201: AC SOLID-INSULATION ENCLOSED SWITCHGEAR AND CONTROLGEAR FOR RATED VOLTAGES ABOVE 1 KV AND UP TO AND INCLUDING 52 KV
IEC 61936-1:2010+AMD1:2014 CSV Power installations exceeding 1 kV a.c. - Part 1: Common rules
UNE-EN 62271-200:2012 High-voltage switchgear and controlgear - Part 200: AC metal-enclosed switchgear and controlgear for rated voltages above 1 kV and up to and including 52 kV
17/30354643 DC : 0 BS EN 62933-2-1 - ELECTRIC ENERGY STORAGE (ESS) SYSTEMS - PART 2-1: UNIT PARAMETERS AND TESTING METHODS - GENERAL SPECIFICATION
09/30213777 DC : 0 BS EN 62271-107 - HIGH-VOLTAGE SWITCHGEAR AND CONTROLGEAR - PART 107: ALTERNATING CURRENT FUSED CIRCUIT-SWITCHERS FOR RATED VOLTAGES ABOVE 1 KV UP TO AND INCLUDING 52 KV
12/30265386 DC : 0 BS EN 62271-3 ED 2 - HIGH-VOLTAGE SWITCHGEAR AND CONTROLGEAR - PART 3: DIGITAL INTERFACES BASED ON IEC 61850
IEC 62505-2:2016 Railway applications - Fixed installations - Particular requirements for AC switchgear - Part 2: Disconnectors, earthing switches and switches with nominal voltage above 1 kV
EN IEC 62933-2-1:2018 Electrical energy storage (EES) systems - Part 2-1: Unit parameters and testing methods - General specification
I.S. EN IEC 62933-2-1:2018 ELECTRICAL ENERGY STORAGE (EES) SYSTEMS - PART 2-1: UNIT PARAMETERS AND TESTING METHODS - GENERAL SPECIFICATION
CEI EN 62271-107 : 2013 HIGH-VOLTAGE SWITCHGEAR AND CONTROLGEAR - PART 107: ALTERNATING CURRENT FUSED CIRCUIT-SWITCHERS FOR RATED VOLTAGES ABOVE 1 KV UP TO AND INCLUDING 52 KV
I.S. EN 50152-2:2012 RAILWAY APPLICATIONS - FIXED INSTALLATIONS - PARTICULAR REQUIREMENTS FOR ALTERNATING CURRENT SWITCHGEAR - PART 2: DISCONNECTORS, EARTHING SWITCHES AND SWITCHES WITH NOMINAL VOLTAGE ABOVE 1 KV
IEC TR 62655:2013 Tutorial and application guide for high-voltage fuses
EN 62271-200:2012/AC:2015 HIGH-VOLTAGE SWITCHGEAR AND CONTROLGEAR - PART 200: AC METAL-ENCLOSED SWITCHGEAR AND CONTROLGEAR FOR RATED VOLTAGES ABOVE 1 KV AND UP TO AND INCLUDING 52 KV (IEC 62271-200:2011)
EN 61936-1 : 2010 AMD 1 2014 POWER INSTALLATIONS EXCEEDING 1 KV A.C. - PART 1: COMMON RULES (IEC 61936-1:2010/A1:2014)
IEC 62933-2-1:2017 Electrical energy storage (EES) systems - Part 2-1: Unit parameters and testing methods - General specification
IEC 62271-105:2012 High-voltage switchgear and controlgear - Part 105: Alternating current switch-fuse combinations for rated voltages above 1 kV up to and including 52 kV
UNE-EN 62271-107:2012 High-voltage switchgear and controlgear - Part 107: Alternating current fused circuit-switchers for rated voltages above 1 kV up to and including 52 kV
I.S. EN 62271-107:2012 HIGH-VOLTAGE SWITCHGEAR AND CONTROLGEAR - PART 107: ALTERNATING CURRENT FUSED CIRCUIT-SWITCHERS FOR RATED VOLTAGES ABOVE 1 KV UP TO AND INCLUDING 52 KV (IEC 62271-107:2012 (EQV))
12/30253935 DC : DRAFT JUNE 2012 BS EN 62271-201 - HIGH-VOLTAGE SWITCHGEAR AND CONTROLGEAR - AC SOLID-INSULATED ENCLOSED SWITCHGEAR AND CONTROLGEAR FOR RATED VOLTAGES ABOVE 1 KV AND UP TO AND INCLUDING 52 KV
PD IEC/TR 62655:2013 Tutorial and application guide for high-voltage fuses
10/30218329 DC : 0 BS EN 62271-105 ED 2 - HIGH-VOLTAGE SWITCHGEAR AND CONTROLGEAR - PART 105: ALTERNATING SWITCH-FUSE COMBINATIONS
11/30235283 DC : 0 BS EN 50152-2 - RAILWAY APPLICATIONS - FIXED INSTALLATIONS - PARTICULAR REQUIREMENTS FOR ALTERNATING CURRENT SWITCHGEAR - PART 2: DISCONNECTORS, EARTHING SWITCHES AND SWITCHES WITH NOMINAL VOLTAGE ABOVE 1 KV
BS EN 50152-2:2012 Railway applications. Fixed installations. Particular requirements for alternating current switchgear Disconnectors, earthing switches and switches with nominal voltage above 1 kV
PREN 50152-2 : DRAFT 2011 RAILWAY APPLICATIONS - FIXED INSTALLATIONS - PARTICULAR REQUIREMENTS FOR ALTERNATING CURRENT SWITCHGEAR - PART 2: DISCONNECTORS, EARTHING SWITCHES AND SWITCHES WITH NOMINAL VOLTAGE ABOVE 1 KV
CEI EN 50152-2 : 2013 RAILWAY APPLICATIONS - FIXED INSTALLATIONS - PARTICULAR REQUIREMENTS FOR ALTERNATING CURRENT SWITCHGEAR - PART 2: DISCONNECTORS, EARTHING SWITCHES AND SWITCHES WITH NOMINAL VOLTAGE ABOVE 1 KV
I.S. EN 61936-1:2010 POWER INSTALLATIONS EXCEEDING 1 KV A.C. - PART 1: COMMON RULES
IEC 60913:2013 Railway applications - Fixed installations - Electric traction overhead contact lines
IEC 62271-106:2011 High-voltage switchgear and controlgear - Part 106: Alternating current contactors, contactor-based controllers and motor-starters
UNE-EN 62271-201:2015 High-voltage switchgear and controlgear - Part 201: AC solid-insulation enclosed switchgear and controlgear for rated voltages above 1 kV and up to and including 52 kV
IEC 62271-3:2015 High-voltage switchgear and controlgear - Part 3: Digital interfaces based on IEC 61850
IEC 62475:2010 High-current test techniques - Definitions and requirements for test currents and measuring systems
IEC 62271-107:2012 High-voltage switchgear and controlgear - Part 107: Alternating current fused circuit-switchers for rated voltages above 1 kV up to and including 52 kV
BS EN 61936-1 : 2010 POWER INSTALLATIONS EXCEEDING 1 KV A.C - PART 1: COMMON RULES
UNE-EN 62271-106:2012 High-voltage switchgear and controlgear - Part 106: Alternating current contactors, contactor-based controllers and motor-starters
UNE-EN 61936-1:2012 Power installations exceeding 1 kV a.c. -- Part 1: Common rules
BS EN 62271-105:2012 High-voltage switchgear and controlgear Alternating current switch-fuse combinations for rated voltages above 1 kV up to and including 52 kV
08/30183795 DC : DRAFT JUNE 2008 BS EN 62271-106 - HIGH-VOLTAGE SWITCHGEAR AND CONTROLGEAR - PART 106: ALTERNATING CURRENT CONTACTORS, CONTACTOR-BASED CONTROLLERS AND CONTACTOR-BASED MOTOR-STARTERS
14/30304423 DC : 0 BS EN 62271-102 ED 2 - HIGH-VOLTAGE SWITCHGEAR AND CONTROLGEAR - PART 102: ALTERNATING CURRENT DISCONNECTORS AND EARTHING SWITCHES
BS EN 62271-201:2014 High-voltage switchgear and controlgear AC solid-insulation enclosed switchgear and controlgear for rated voltages above 1 kV and up to and including 52 kV
UNE-EN 62475:2012 High-current test techniques - Definitions and requirements for test currents and measuring systems
I.S. EN 62475:2010 HIGH-CURRENT TEST TECHNIQUES - DEFINITIONS AND REQUIREMENTS FOR TEST CURRENTS AND MEASURING SYSTEMS
EN 62271-106:2011 High-voltage switchgear and controlgear - Part 106: Alternating current contactors, contactor-based controllers and motor-starters
I.S. EN 62271-201:2014 HIGH-VOLTAGE SWITCHGEAR AND CONTROLGEAR - PART 201: AC SOLID-INSULATION ENCLOSED SWITCHGEAR AND CONTROLGEAR FOR RATED VOLTAGES ABOVE 1 KV AND UP TO AND INCLUDING 52 KV
UNE-EN 62271-105:2013 High-voltage switchgear and controlgear - Part 105: Alternating current switch-fuse combinations for rated voltages above 1 kV up to and including 52 kV
IEC 62271-201:2014 High-voltage switchgear and controlgear - Part 201: AC solid-insulation enclosed switchgear and controlgear for rated voltages above 1 kV and up to and including 52 kV
IEC 62271-200:2011 High-voltage switchgear and controlgear - Part 200: AC metal-enclosed switchgear and controlgear for rated voltages above 1 kV and up to and including 52 kV
EN 50152-2:2012 RAILWAY APPLICATIONS - FIXED INSTALLATIONS - PARTICULAR REQUIREMENTS FOR ALTERNATING CURRENT SWITCHGEAR - PART 2: DISCONNECTORS, EARTHING SWITCHES AND SWITCHES WITH NOMINAL VOLTAGE ABOVE 1 KV
EN 62271-107:2012 HIGH-VOLTAGE SWITCHGEAR AND CONTROLGEAR - PART 107: ALTERNATING CURRENT FUSED CIRCUIT-SWITCHERS FOR RATED VOLTAGES ABOVE 1 KV UP TO AND INCLUDING 52 KV (IEC 62271-107:2012)

IEC 62271-100:2008+AMD1:2012+AMD2:2017 CSV High-voltage switchgear and controlgear - Part 100: Alternating-current circuit-breakers
IEC 62271-110:2017 High-voltage switchgear and controlgear - Part 110: Inductive load switching
IEC 62271-105:2012 High-voltage switchgear and controlgear - Part 105: Alternating current switch-fuse combinations for rated voltages above 1 kV up to and including 52 kV
AS IEC 62475:2019 High-current test techniques - Definitions and requirements for test currents and measuring systems
IEC 60050-441:1984 International Electrotechnical Vocabulary (IEV) - Part 441: Switchgear, controlgear and fuses
IEC 60529:1989+AMD1:1999+AMD2:2013 CSV Degrees of protection provided by enclosures (IP Code)
IEC 62271-1:2017 High-voltage switchgear and controlgear - Part 1: Common specifications for alternating current switchgear and controlgear
IEC 60059:1999+AMD1:2009 CSV IEC standard current ratings
IEC 60507:2013 Artificial pollution tests on high-voltage ceramic and glass insulators to be used on a.c. systems
IEC 60071-1:2006+AMD1:2010 CSV Insulation co-ordination - Part 1: Definitions, principles and rules
IEC 62271-102:2001+AMD1:2011+AMD2:2013 CSV High-voltage switchgear and controlgear - Part 102: Alternatingcurrent disconnectors and earthing switches

View more information
US$400.00
Excluding Tax where applicable

Access your standards online with a subscription

Features

  • Simple online access to standards, technical information and regulations.

  • Critical updates of standards and customisable alerts and notifications.

  • Multi-user online standards collection: secure, flexible and cost effective.