Electromagnetic compatibility (EMC) - Part 3-6: Limits - Assessment of emission limits for the connection of distorting installations to MV, HV and EHV power systems
Available format(s)

Hardcopy , PDF , PDF 3 Users , PDF 5 Users , PDF 9 Users

Language(s)

English

Published date

02-22-2008

This Technical Report, which is informative in its nature, provides guidance on principles which can be used as the basis for determining the requirements for the connection of distorting installations to MV, HV and EHV public power systems (LV installations are covered in other IEC documents). For the purposes of this report, a distorting installation means an installation (which may be a load or a generator) that produces harmonics and/or interharmonics. The primary objective is to provide guidance to system operators or owners on engineering practices, which will facilitate the provision of adequate service quality for all connected customers. In addressing installations, this document is not intended to replace equipment standards for emission limits. The report addresses the allocation of the capacity of the system to absorb disturbances. It does not address how to mitigate disturbances, nor does it address how the capacity of the system can be increased. Since the guidelines outlined in this report are necessarily based on certain simplifying assumptions, there is no guarantee that this approach will always provide the optimum solution for all harmonic situations. The recommended approach should be used with flexibility and judgment as far as engineering is concerned, when applying the given assessment procedures in full or in part. The system operator or owner is responsible for specifying requirements for the connection of distorting installations to the system. The distorting installation is to be understood as the customer's complete installation (i.e. including distorting and non-distorting parts). Problems related to harmonics fall into two basic categories:
/ - Harmonic currents that are injected into the supply system by converters and harmonic sources, giving rise to harmonic voltages in the system. Both harmonic currents and resulting voltages can be considered as conducted phenomena.
- Harmonic currents that induce interference into communication systems. This phenomenon is more pronounced at higher order harmonic frequencies because of increased coupling between the circuits and because of the higher sensitivity of the communication circuits in the audible range.
This report gives guidance for the co-ordination of the harmonic voltages between different voltage levels in order to meet the compatibility levels at the point of utilisation. The recommendations in this report do not address harmonic interference phenomena in communication circuits (i.e. only the first of the above categories is addressed). This second edition cancels and replaces the first edition published in 1996 and constitutes a technical revision. This edition is significantly more streamlined than first edition, and it reflects the experiences gained in the application of the first edition. As part of this streamlining process, this second edition of IEC/TR 61000-3-6 does not address communications circuit interference. Clause 9 on this (section 10) was removed, as this did not suitably address emission limits for telephone interference. The scope has been adjusted to point out that IEC/TR 61000-3-6 does not address communications circuit interference. This edition has also been harmonised with IEC/TR 61000-3-7 and IEC/TR 61000-3-13. This Technical Report has the status of a basic EMC publication in accordance with IEC Guide 107.

Committee
TC 77/SC 77A
DevelopmentNote
Supersedes IEC 61000-3-6. (02/2008) Stability Date: 2018. (09/2017)
DocumentType
Technical Report
Pages
58
PublisherName
International Electrotechnical Committee
Status
Current
Supersedes

Standards Relationship
PD IEC/TR 61000-3-6:2008 Identical
NEN NPR IEC/TR 61000-3-6 : 2008 Identical
TR IEC 61000.3.6:2012 Identical

EN 61000-4-30:2015/AC:2017-01 ELECTROMAGNETIC COMPATIBILITY (EMC) - PART 4-30: TESTING AND MEASUREMENT TECHNIQUES - POWER QUALITY MEASUREMENT METHODS (IEC 61000-4-30:2015/COR1:2016)
BIS IS 16071 : 2013 HIGH-VOLTAGE DIRECT CURRENT (HVDC) SYSTEMS - GUIDEBOOK TO THE SPECIFICATION AND DESIGN EVALUATION OF A.C. FILTERS
12/30257420 DC : 0 BS EN 61851-23 ED 1.0 - ELECTRIC VEHICLE CONDUCTIVE CHARGING SYSTEM - PART 23: D.C. ELECTRIC VEHICLE CHARGING STATION
PD IEC/TR 61000-3-13:2008 Electromagnetic compatibility (EMC) Limits. Assessment of emission limits for the connection of unbalanced installations to MV, HV and EHV power systems
12/30262567 DC : 0 BS EN 61000-4-30 ED 3 - ELECTROMAGNETIC COMPATIBILITY (EMC) - PART 4-30: TESTING AND MEASUREMENT TECHNIQUES - POWER QUALITY MEASUREMENT METHODS
UNE-EN 61000-4-30:2015 Electromagnetic compatibility (EMC) - Part 4-30: Testing and measurement techniques - Power quality measurement methods
S.R. CLC/TR 50422:2013 GUIDE FOR THE APPLICATION OF THE EUROPEAN STANDARD EN 50160
PD IEC/TR 61850-90-17:2017 Communication networks and systems for power utility automation Using IEC 61850 to transmit power quality data
CSA C61000.3.7 :2009 ELECTROMAGNETIC COMPATIBILITY (EMC) - PART 3-7: LIMITS - ASSESSMENT OF EMISSION LIMITS FOR THE CONNECTION OF FLUCTUATING INSTALLATIONS TO MV, HV AND EHV POWER SYSTEMS
CSA C61000-3-13 : 2009 : R2017 ELECTROMAGNETIC COMPATIBILITY (EMC) - PART 3-13: LIMITS - ASSESSMENT OF EMISSION LIMITS FOR THE CONNECTION OF UNBALANCED INSTALLATIONS TO MV, HV AND EHV POWER SYSTEMS
PD CLC/TR 50646:2015 Railway Application. Fixed Installations. Specification for reversible d.c. substations
CEI EN 61000-3-12 : 2012 ELECTROMAGNETIC COMPATIBILITY (EMC) - PART 3-12: LIMITS - LIMITS FOR HARMONIC CURRENTS PRODUCED BY EQUIPMENT CONNECTED TO PUBLIC LOW-VOLTAGE SYSTEMS WITH INPUT CURRENT > 16 A AND <= 75 A PER PHASE
I.S. EN 61000-4-30:2015 ELECTROMAGNETIC COMPATIBILITY (EMC) - PART 4-30: TESTING AND MEASUREMENT TECHNIQUES - POWER QUALITY MEASUREMENT METHODS
I.S. EN 61400-21:2008 WIND TURBINES - PART 21: MEASUREMENT AND ASSESSMENT OF POWER QUALITY CHARACTERISTICS OF GRID CONNECTED WIND TURBINES
BS EN 60519-1:2015 Safety in installations for electroheating and electromagnetic processing General requirements
EN 61000-3-12:2011 ELECTROMAGNETIC COMPATIBILITY (EMC) - PART 3-12: LIMITS - LIMITS FOR HARMONIC CURRENTS PRODUCED BY EQUIPMENT CONNECTED TO PUBLIC LOW-VOLTAGE SYSTEMS WITH INPUT CURRENT > 16 A AND <= 75 A PER PHASE (IEC 61000-3-12:2011)
EN 60519-1:2015 Safety in installations for electroheating and electromagnetic processing - Part 1: General requirements
CLC/TR 50422:2013 GUIDE FOR THE APPLICATION OF THE EUROPEAN STANDARD EN 50160
BS EN 62920:2017 Photovoltaic power generating systems. EMC requirements and test methods for power conversion equipment
IEC TR 62001-1:2016 High-voltage direct current (HVDC) systems - Guidance to the specification and design evaluation of AC filters - Part 1: Overview
PD IEC/TR 62001-2:2016 High-voltage direct current (HVDC) systems. Guidance to the specification and design evaluation of AC filters Performance
IEEE 1453.1-2012 IEEE Guide--Adoption of IEC/TR 61000-3-7:2008, Electromagnetic compatibility (EMC)--Limits--Assessment of emission limits for the connection of fluctuating installations to MV, HV and EHV power systems
UNE-EN 61000-3-12:2012 Electromagnetic compatibility (EMC) - Part 3-12: Limits - Limits for harmonic currents produced by equipment connected to public low-voltage systems with input current > 16 A and
S.R. CLC/TS 50549-2:2015 REQUIREMENTS FOR GENERATING PLANTS TO BE CONNECTED IN PARALLEL WITH DISTRIBUTION NETWORKS - PART 2: CONNECTION TO A MV DISTRIBUTION NETWORK
CSA C61000-3-14 : 2015 ELECTROMAGNETIC COMPATIBILITY (EMC) - PART 3-14: ASSESSMENT OF EMISSION LIMITS FOR HARMONICS, INTERHARMONICS, VOLTAGE FLUCTUATIONS AND UNBALANCE FOR THE CONNECTION OF DISTURBING INSTALLATIONS TO LV POWER SYSTEMS
CEI EN 62920 : 1ED 2018 PHOTOVOLTAIC POWER GENERATING SYSTEMS - EMC REQUIREMENTS AND TEST METHODS FOR POWER CONVERSION EQUIPMENT
IEC TR 61000-3-7:2008 Electromagnetic compatibility (EMC) - Part 3-7: Limits - Assessment of emission limits for the connection of fluctuating installations to MV, HV and EHV power systems
IEC TR 62001:2009 High-voltage direct current (HVDC) systems - Guidebook to the specification and design evaluation of A.C. filters
I.S. EN 62135-2:2015 RESISTANCE WELDING EQUIPMENT - PART 2: ELECTROMAGNETIC COMPATIBILITY (EMC) REQUIREMENTS
17/30354643 DC : 0 BS EN 62933-2-1 - ELECTRIC ENERGY STORAGE (ESS) SYSTEMS - PART 2-1: UNIT PARAMETERS AND TESTING METHODS - GENERAL SPECIFICATION
PD IEC/TR 62001-3:2016 High-voltage direct current (HVDC) systems. Guidance to the specification and design evaluation of AC filters Modelling
PD IEC/TR 62001-1:2016 High-voltage direct current (HVDC) systems. Guidance to the specification and design evaluation of AC filters Overview
S.R. CLC/TS 50654-1:2018 HVDC GRID SYSTEMS AND CONNECTED CONVERTER STATIONS - GUIDELINE AND PARAMETER LISTS FOR FUNCTIONAL SPECIFICATIONS - PART 1: GUIDELINES
ENA ER G5-4-1 : ISSUE 4 AMD 1 2005 PLANNING LEVELS FOR HARMONIC VOLTAGE DISTORTION AND THE CONNECTION OF NON-LINEAR EQUIPMENT TO TRANSMISSION SYSTEMS AND DISTRIBUTION NETWORKS IN THE UNITED KINGDOM
BS EN 61000-4-30:2015 Electromagnetic compatibility (EMC) Testing and measurement techniques. Power quality measurement methods
DD IEC PAS 62543 : DRAFT 2008 DC TRANSMISSION USING VOLTAGE SOURCED CONVERTERS
PD CLC/TS 50654-1:2018 HVDC Grid Systems and connected Converter Stations. Guideline and Parameter Lists for Functional Specifications Guidelines
CSA C61000-4-30 : 2010 ELECTROMAGNETIC COMPATIBILITY (EMC) - PART 4-30: TESTING AND MEASUREMENT TECHNIQUES - POWER QUALITY MEASUREMENT METHODS
16/30332623 DC : 0 BS EN 62920 ED 1.0 - EMC REQUIREMENTS AND TEST METHODS FOR POWER CONVERSION EQUIPMENT APPLYING TO PHOTOVOLTAIC POWER GENERATING SYSTEMS
PD IEC/TR 62001:2009 High-voltage direct current (HVDC) systems. Guidebook to the specification and design evaluation of A.C. filters
EN IEC 62933-2-1:2018 Electrical energy storage (EES) systems - Part 2-1: Unit parameters and testing methods - General specification
PD CLC/TR 50422:2013 Guide for the application of the European Standard EN 50160
IEC TR 61000-3-15:2011 Electromagnetic compatibility (EMC) - Part 3-15: Limits - Assessment of low frequency electromagnetic immunity and emission requirements for dispersed generation systems in LV network
IEC TR 62001-2:2016 High-voltage direct current (HVDC) systems - Guidance to the specification and design evaluation of AC filters - Part 2: Performance
IEC 62933-2-1:2017 Electrical energy storage (EES) systems - Part 2-1: Unit parameters and testing methods - General specification
CEI EN 60519-1 : 2016 SAFETY IN INSTALLATIONS FOR ELECTROHEATING AND ELECTROMAGNETIC PROCESSING - PART 1: GENERAL REQUIREMENTS
CEI CLC/TR 50422 : 2015 GUIDE FOR THE APPLICATION OF THE EUROPEAN STANDARD EN 50160
CSA C61000-3-14:15 (R2019) Electromagnetic compatibility (EMC) — Part 3-14: Assessment of emission limits for harmonics, interharmonics, voltage fluctuations and unbalance for the connection of disturbing installations to LV power systems (Adopted IEC/TR 61000-3-14:2011, first edition, 2011-10, with Canadian deviations)
S.R. CLC/TR 50646:2015 RAILWAY APPLICATION - FIXED INSTALLATIONS - SPECIFICATION FORREVERSIBLE D.C. SUBSTATIONS
PD IEC/TR 61000-3-14:2011 Electromagnetic compatibility (EMC) Assessment of emission limits for harmonics, interharmonics, voltage fluctuations and unbalance for the connection of disturbing installations to LV power systems
PD IEC/TR 61000-3-15:2011 Electromagnetic compatibility (EMC) Limits. Assessment of low frequency electromagnetic immunity and emission requirements for dispersed generation systems in LV network
02/204840 DC : DRAFT APR 2002 PREN 50217 - IN SITU MEASUREMENTS OF DISTURBANCE EMISSION
CLC/TS 50549-2:2015 Requirements for generating plants to be connected in parallel with distribution networks - Part 2: Connection to a MV distribution network
CSA C61000-3-13 : 2009 : R2014 ELECTROMAGNETIC COMPATIBILITY (EMC) - PART 3-13: LIMITS - ASSESSMENT OF EMISSION LIMITS FOR THE CONNECTION OF UNBALANCED INSTALLATIONS TO MV, HV AND EHV POWER SYSTEMS
CSA C61000-3-13 :2009 ELECTROMAGNETIC COMPATIBILITY (EMC) - PART 3-13: LIMITS - ASSESSMENT OF EMISSION LIMITS FOR THE CONNECTION OF UNBALANCED INSTALLATIONS TO MV, HV AND EHV POWER SYSTEMS
IEC TR 61000-3-13:2008 Electromagnetic compatibility (EMC) - Part 3-13: Limits - Assessment of emission limits for the connection of unbalanced installations to MV, HV and EHV power systems
I.S. EN 62920:2017 PHOTOVOLTAIC POWER GENERATING SYSTEMS - EMC REQUIREMENTS AND TEST METHODS FOR POWER CONVERSION EQUIPMENT
CLC/TS 50654-1:2018 HVDC Grid Systems and connected Converter Stations - Guideline and Parameter Lists for Functional Specifications - Part 1: Guidelines
IEC TR 62001-3:2016 High-voltage direct current (HVDC) systems - Guidance to the specification and design evaluation of AC filters - Part 3: Modelling
IEC TR 61850-90-17:2017 Communication networks and systems for power utility automation - Part 90-17: Using IEC 61850 to transmit power quality data
CEI EN 60146-1-1 : 2013 SEMICONDUCTOR CONVERTERS - GENERAL REQUIREMENTS AND LINE COMMUTATED CONVERTERS - PART 1-1: SPECIFICATION OF BASIC REQUIREMENTS
IEC 61800-3:2017 Adjustable speed electrical power drive systems - Part 3: EMC requirements and specific test methods
IEC TR 62001-4:2016 High-voltage direct current (HVDC) systems - Guidance to the specification and design evaluation of AC filters - Part 4: Equipment
IEC TS 62749:2015 Assessment of power quality - Characteristics of electricity supplied by public networks
IEC TR 61000-3-14:2011 Electromagnetic compatibility (EMC) - Part 3-14: Assessment of emission limits for harmonics, interharmonics, voltage fluctuations and unbalance for the connection of disturbing installations to LV power systems
IEC 60519-1:2015 Safety in installations for electroheating and electromagnetic processing - Part 1: General requirements
13/30277685 DC : 0 BS EN 60519-1 - SAFETY IN INSTALLATIONS FOR ELECTROHEATING AND ELECTROMAGNETIC PROCESSING - PART 1: GENERAL REQUIREMENTS
IEC 61000-4-30 : 3.0EN+(REDLINE+VERSION) ELECTROMAGNETIC COMPATIBILITY (EMC) - PART 4-30: TESTING AND MEASUREMENT TECHNIQUES - POWER QUALITY MEASUREMENT METHODS
09/30204029 DC : 0 BS EN 61439-1 - LOW-VOLTAGE SWITCHGEAR AND CONTROLGEAR ASSEMBLIES - PART 1: GENERAL RULES
IEC 61000-3-12:2011 Electromagnetic compatibility (EMC) - Part 3-12: Limits - Limits for harmonic currents produced by equipment connected to public low-voltage systems with input current >16 A and ≤ 75 A per phase
IEC 61000-4-30:2015 RLV Electromagnetic compatibility (EMC) - Part 4-30: Testing and measurement techniques - Power quality measurement methods
IEC 62135-2:2015 Resistance welding equipment - Part 2: Electromagnetic compatibility (EMC) requirements
IEC 61400-21:2008 Wind turbines - Part 21: Measurement and assessment of power quality characteristics of grid connected wind turbines
BS EN 61400-21:2008 Wind turbines Measurement and assessment of power quality characteristics of grid connected wind turbines
NF EN 62920 : 2017 PHOTOVOLTAIC POWER GENERATING SYSTEMS - EMC REQUIREMENTS AND TEST METHODS FOR POWER CONVERSION EQUIPMENT
BS EN 62135-2:2015 Resistance welding equipment Electromagnetic compatibility (EMC) requirements
14/30269850 DC : 0 BS EN 62135-2 - ED 2.0 - RESISTANCE WELDING EQUIPMENT - PART 2: ELECTROMAGNETIC COMPATIBILITY (EMC) REQUIREMENTS
PD IEC/TR 62001-4:2016 High-voltage direct current (HVDC) systems. Guidance to the specification and design evaluation of AC filters Equipment
CSA C61000.3.7 : 2009 : R2017 ELECTROMAGNETIC COMPATIBILITY (EMC) - PART 3-7: LIMITS - ASSESSMENT OF EMISSION LIMITS FOR THE CONNECTION OF FLUCTUATING INSTALLATIONS TO MV, HV AND EHV POWER SYSTEMS
CSA C61000.3.7 : 2009 : R2014 ELECTROMAGNETIC COMPATIBILITY (EMC) - PART 3-7: LIMITS - ASSESSMENT OF EMISSION LIMITS FOR THE CONNECTION OF FLUCTUATING INSTALLATIONS TO MV, HV AND EHV POWER SYSTEMS
BS EN 61000-3-12:2011 Electromagnetic compatibility (EMC) Limits. Limits for harmonic currents produced by equipment connected to public low-voltage systems with input current > 16 A and ≤ 75 A per phase
PD IEC/TR 61000-3-7:2008 Electromagnetic compatability (EMC) Limits. Assessment of emission limits for the connection of fluctuating installations to MV, HV and EHV power systems
BS EN 60146-1-1:2010 Semiconductor converters. General requirements and line commutated converters Specification of basic requirements
I.S. EN 61000-3-12:2011 ELECTROMAGNETIC COMPATIBILITY (EMC) - PART 3-12: LIMITS - LIMITS FOR HARMONIC CURRENTS PRODUCED BY EQUIPMENT CONNECTED TO PUBLIC LOW-VOLTAGE SYSTEMS WITH INPUT CURRENT > 16 A AND <= 75 A PER PHASE (IEC 61000-3-12:2011 (EQV))
CSA C61000-4-30 : 2010 : R2014 ELECTROMAGNETIC COMPATIBILITY (EMC) - PART 4-30: TESTING AND MEASUREMENT TECHNIQUES - POWER QUALITY MEASUREMENT METHODS
I.S. EN IEC 62933-2-1:2018 ELECTRICAL ENERGY STORAGE (EES) SYSTEMS - PART 2-1: UNIT PARAMETERS AND TESTING METHODS - GENERAL SPECIFICATION
CEI EN 61400-21 : 2011 WIND TURBINES - PART 21: MEASUREMENT AND ASSESSMENT OF POWER QUALITY CHARACTERISTICS OF GRID CONNECTED WIND TURBINES
EN 62920:2017 Photovoltaic power generating systems - EMC requirements and test methods for power conversion equipment
IEC PAS 62543:2008 DC transmission using voltage sourced converters
I.S. EN 60519-1:2015 SAFETY IN INSTALLATIONS FOR ELECTROHEATING AND ELECTROMAGNETIC PROCESSING - PART 1: GENERAL REQUIREMENTS
EN 61400-21:2008 WIND TURBINES - PART 21: MEASUREMENT AND ASSESSMENT OF POWER QUALITY CHARACTERISTICS OF GRID CONNECTED WIND TURBINES
EN 62135-2:2015 Resistance welding equipment - Part 2: Electromagnetic compatibility (EMC) requirements
CLC/TR 50646:2015 Railway Application - Fixed Installations - Specification for reversible d.c. substations

IEC TR 61000-2-6:1995 Electromagnetic compatibility (EMC) - Part 2: Environment - Section 6: Assessment of the emission levels in the power supply of industrial plants as regards low-frequency conducted disturbances
IEC 61000-4-30 : 3.0EN+(REDLINE+VERSION) ELECTROMAGNETIC COMPATIBILITY (EMC) - PART 4-30: TESTING AND MEASUREMENT TECHNIQUES - POWER QUALITY MEASUREMENT METHODS
IEC GUIDE 107:2014 Electromagnetic compatibility - Guide to the drafting of electromagnetic compatibility publications
IEC 61000-2-12:2003 Electromagnetic compatibility (EMC) - Part 2-12: Environment - Compatibility levels for low-frequency conducted disturbances and signalling in public medium-voltage power supply systems
IEC 60050-601:1985 International Electrotechnical Vocabulary (IEV) - Part 601: Generation, transmission and distribution of electricity - General
IEC TR 61000-3-13:2008 Electromagnetic compatibility (EMC) - Part 3-13: Limits - Assessment of emission limits for the connection of unbalanced installations to MV, HV and EHV power systems
IEC 61000-3-12:2011 Electromagnetic compatibility (EMC) - Part 3-12: Limits - Limits for harmonic currents produced by equipment connected to public low-voltage systems with input current >16 A and ≤ 75 A per phase
IEC 60050-101:1998 International Electrotechnical Vocabulary (IEV) - Part 101: Mathematics
IEEE 1137-1991 IEEE Guide for the Implementation of Inductive Coordination Mitigation Techniques and Application
IEC TR 61000-3-7:2008 Electromagnetic compatibility (EMC) - Part 3-7: Limits - Assessment of emission limits for the connection of fluctuating installations to MV, HV and EHV power systems
IEC TS 61000-3-4:1998 Electromagnetic compatibility (EMC) - Part 3-4: Limits - Limitation of emission of harmonic currents in low-voltage power supply systems for equipment with rated current greater than 16 A
IEC TR 61000-2-1:1990 Electromagnetic compatibility (EMC) - Part 2: Environment - Section 1: Description of the environment - Electromagnetic environment for low-frequency conducted disturbances and signalling in public power supply systems
IEC 61000-2-2:2002+AMD1:2017 CSV Electromagnetic compatibility (EMC) - Part 2-2: Environment - Compatibility levels for low-frequency conducted disturbances and signalling in public low-voltage power supply systems
IEC 61000-4-7:2002+AMD1:2008 CSV Electromagnetic compatibility (EMC) - Part 4-7: Testing and measurement techniques - General guide on harmonics and interharmonics measurements and instrumentation, for power supply systems and equipment connected thereto
IEEE 776-1992 IEEE Recommended Practice for Inductive Coordination of Electric Supply and Communication Lines
IEC 61000-3-2 : 4.0 ELECTROMAGNETIC COMPATIBILITY (EMC) - PART 3-2: LIMITS - LIMITS FOR HARMONIC CURRENT EMISSIONS (EQUIPMENT INPUT CURRENT <= 16 A PER PHASE)

View more information
US$348.00
Excluding Tax where applicable

Access your standards online with a subscription

Features

  • Simple online access to standards, technical information and regulations.

  • Critical updates of standards and customisable alerts and notifications.

  • Multi-user online standards collection: secure, flexible and cost effective.