• There are no items in your cart

IEC TS 61245:2015

Current
Current

The latest, up-to-date edition.

Artificial pollution tests on high-voltage ceramic and glass insulators to be used on d.c. systems
Available format(s)

Hardcopy , PDF , PDF 3 Users , PDF 5 Users , PDF 9 Users

Language(s)

English

Published date

03-30-2015

FOREWORD
INTRODUCTION
1 Scope
2 Normative references
3 Terms and definitions
4 General test requirements
5 Salt fog method
6 Solid layer method
Annex A (informative) - Method for checking the uniformity
        of the layer
Annex B (informative) - Determination of the withstand
        characteristics of insulators
Annex C (informative) - Additional recommendations concerning
        the solid layer method procedures
Annex D (informative) - Information to check equipment for
        artificial pollution tests
Annex E (informative) - Supplementary information on artificial
        pollution tests on insulators for voltage systems of
        [+/-] 600 kV and above (solid layer method procedure B)
Annex F (informative) - Further investigation
Bibliography

IEC TS 61245:2015(E) is applicable for the determination of the d.c. withstand characteristics of ceramic and glass insulators to be used outdoors and exposed to polluted atmospheres, on d.c. systems with the highest voltage of the system greater than +/- 1 000 V. These tests are not applicable to polymeric insulators, to greased insulators or to special types of insulators (e.g. insulators with semiconducting glaze or covered with any organic insulating material). The object of this technical specification is to prescribe procedures for artificial pollution tests applicable to insulators for overhead lines, substations and traction lines and to bushings. This second edition cancels and replaces the first edition published in 1993. This edition constitutes a technical revision. This edition includes the following significant technical changes with respect to the previous edition:
a) Corrections and the addition of explanatory material;
b) The addition of Clause 4.4.2 on atmospheric correction;
c) The change of upper limit of volume conductivity of tap water for insulator cleaning to 0,1 S/m;
d) The extension to UHV voltages; and
e) The addition of Annex B "Determination of the withstand characteristics of insulators" and Annex E "Supplementary information on artificial pollution tests on insulators for voltage systems of +/- 600 kV and above (solid layer method procedure B).
The contents of the corrigendum of August 2018 have been included in this copy.

Committee
TC 36
DevelopmentNote
Stability date: 2017. (04/2015)
DocumentType
Technical Specification
Pages
37
PublisherName
International Electrotechnical Committee
Status
Current
Supersedes

Standards Relationship
PD IEC TS 61245:2015 Identical
DIN IEC/TS 61245 : 2017 Identical
VDE V 0674-254 : 2017 Identical
UNE 21201:1999 IN Identical

NF EN 62199 : 2004 BUSHINGS FOR D.C. APPLICATION
UNE-EN 50124-1:2017 Railway applications - Insulation coordination - Part 1: Basic requirements - Clearances and creepage distances for all electrical and electronic equipment
CEI EN 62231 : 2007 COMPOSITE STATION POST INSULATORS FOR SUBSTATIONS WITH A.C. VOLTAGES GREATER THAN 1000 V UP TO 245 KV - DEFINITIONS, TEST METHODS AND ACCEPTANCE CRITERIA
BS EN 50123-7-3:2003 Railway applications. Fixed installations. d.c. switchgear. Measurement, control and protection devices for specific use in d.c. traction systems Isolating voltage transducers and other voltage measuring devices
BS IEC/IEEE 65700-19-03 : 2014 BUSHINGS FOR DC APPLICATION
11/30247685 DC : 0 BS EN 65700-19-03 - BUSHINGS FOR DC APPLICATION
PREN 50119 : DRAFT 2017 RAILWAY APPLICATIONS - FIXED INSTALLATIONS - ELECTRIC TRACTION OVERHEAD CONTACT LINES
DD IEC/TS 60815-1:2008 Selection and dimensioning of high-voltage insulators intended for use in polluted conditions Definitions, information and general principles
CSA C1325 : 1999 : R2016 INSULATORS FOR OVERHEAD LINES WITH A NOMINAL VOLTAGE ABOVE 1000 V - CERAMIC OR GLASS INSULATOR UNITS FOR D.C. SYSTEMS - DEFINITIONS, TEST METHODS AND ACCEPTANCE CRITERIA
CSA C62155 : 2006 : R2015 HOLLOW PRESSURIZED AND UNPRESSURIZED CERAMIC AND GLASS INSULATORS FOR USE IN ELECTRICAL EQUIPMENT WITH RATED VOLTAGES GREATER THAN 1000 V
I.S. EN 50123-1:2003 RAILWAY APPLICATIONS - FIXED INSTALLATIONS - D.C. SWITCHGEAR - GENERAL
I.S. EN 61325:1997 INSULATORS FOR OVERHEAD LINES WITH A NOMINAL VOLTAGE ABOVE 1000 V - CERAMIC OR GLASS INSULATOR UNITS FOR D.C. SYSTEMS - DEFINITIONS, TEST METHODS AND ACCEPTANCE CRITERIA
CEI 36-41 : 2011 SELECTION AND DIMENSIONING OF HIGH-VOLTAGE INSULATORS INTENDED FOR USE IN POLLUTED CONDITIONS - PART 1: DEFINITIONS, INFORMATION AND GENERAL PRINCIPLES
CEI EN 62199 : 2005 BUSHINGS FOR D.C. APPLICATION
BS EN 50123-7-2:2003 Railway applications. Fixed installations. d.c. switchgear. Measurement, control and protection devices for specific use in d.c. traction systems Isolating current transducers and other current measuring devices
IEC 62497-1:2010+AMD1:2013 CSV Railway applications - Insulation coordination - Part 1: Basic requirements - Clearances and creepage distances for all electricaland electronic equipment
EN 62155:2003 Hollow pressurized and unpressurized ceramic and glass insulators for use in electrical equipment with rated voltages greater than 1 000 V
EN 62231:2006 Composite station post insulators for substations with a.c. voltages greater than 1 000 V up to 245 kV - Definitions, test methods and acceptance criteria
EN 62199:2004 Bushings for d.c. application
OVE/ONORM EN 50124-1 : 2011-05 RAILWAY APPLICATIONS - INSULATION COORDINATION - PART 1: BASIC REQUIREMENTS - CLEARANCES AND CREEPAGE DISTANCES FOR ALL ELECTRICAL AND ELECTRONIC EQUIPMENT
06/30126000 DC : DRAFT MAY 2006 IEC 60815-1 - SELECTION AND DIMENSIONING OF HIGH-VOLTAGE INSULATORS FOR POLLUTED CONDITIONS - PART 1: DEFINITIONS, INFORMATION AND GENERAL PRINCIPLES
I.S. EN 50123-3:2003 RAILWAY APPLICATIONS - FIXED INSTALLATIONS - D.C. SWITCHGEAR - PART 3: INDOOR D.C. DISCONNECTORS, SWITCH-DISCONNECTORS AND EARTHING SWITCHES
BS EN 62155:2003 Hollow pressurized and unpressurized ceramic and glass insulators for use in electrical equipment with rated voltages greater than 1000 V
CEI EN 62217 : 2013 POLYMERIC HV INSULATORS FOR INDOOR AND OUTDOOR USE - GENERAL DEFINITIONS, TEST METHODS AND ACCEPTANCE CRITERIA
17/30341013 DC : DRAFT AUG 2017 BS EN 50119 - RAILWAY APPLICATIONS - FIXED INSTALLATIONS - ELECTRIC TRACTION OVERHEAD CONTACT LINES
11/30215604 DC : 0 BS IEC 60913 - RAILWAY APPLICATIONS - FIXED INSTALLATIONS - ELECTRIC TRACTION OVERHEAD CONTACT LINES
CEI EN 62155 : 2004 HOLLOW PRESSURIZED AND UNPRESSURIZED CERAMIC AND GLASS INSULATORS FOR USE IN ELECTRICAL EQUIPMENT WITH RATED VOLTAGES GREATER THAN 1000 V
95/206959 DC : 0 IEC 61540 - PORTABLE RESIDUAL CURRENT DEVICES WITHOUT INTEGRAL OVERCURRENT PROTECTION FOR HOUSEHOLD AND SIMILAR USE (PRCD'S)
BS EN 62199:2004 Bushings for D.C. application
CSA C62155:2006 HOLLOW PRESSURIZED AND UNPRESSURIZED CERAMIC AND GLASS INSULATORS FOR USE IN ELECTRICAL EQUIPMENT WITH RATED VOLTAGES GREATER THAN 1000 V
EN 50123-7-2:2003 Railway applications - Fixed installations - D.C. switchgear - Part 7-2: Measurement, control and protection devices for specific use in d.c. traction systems - Isolating current transducers and other current measuring devices
BS EN 50123-1:2003 Railway applications. Fixed installations. D.C. switchgear General
I.S. EN 50123-4:2003 RAILWAY APPLICATIONS - FIXED INSTALLATIONS - D.C. SWITCHGEAR - PART 4: OUTDOOR D.C. DISCONNECTORS, SWITCH-DISCONNECTORS AND EARTHING SWITCHES
IEEE 1898-2016 IEEE Standard for High-Voltage Direct-Current (HVDC) Composite Post Insulators
CEI EN 61325 : 1998 INSULATORS FOR OVERHEAD LINES WITH A NOMINAL VOLTAGE ABOVE 1000 V CERAMIC OR GLASS INSULATOR UNITS FOR D.C. SYSTEMS DEFINITIONS, TEST METHODS AND ACCEPTANCE CRITERIA
I.S. EN 50124-1:2017 RAILWAY APPLICATIONS - INSULATION COORDINATION - PART 1: BASIC REQUIREMENTS - CLEARANCES AND CREEPAGE DISTANCES FOR ALL ELECTRICAL AND ELECTRONIC EQUIPMENT
I.S. EN 50123-7-2:2003 RAILWAY APPLICATIONS - FIXED INSTALLATIONS - D.C. SWITCHGEAR - PART 7-2: MEASUREMENT, CONTROL AND PROTECTION DEVICES FOR SPECIFIC USE IN D.C. TRACTION SYSTEMS - ISOLATING CURRENT TRANSDUCERS AND OTHER CURRENT MEASURING DEVICES
I.S. EN 62231:2007 COMPOSITE STATION POST INSULATORS FOR SUBSTATIONS WITH A.C. VOLTAGES GREATER THAN 1 000 V UP TO 245 KV - DEFINITIONS, TEST METHODS AND ACCEPTANCE CRITERIA
IEC/IEEE 65700-19-03:2014 Bushings for DC application
I.S. EN 50119:2009 RAILWAY APPLICATIONS - FIXED INSTALLATIONS - ELECTRIC TRACTION OVERHEAD CONTACT LINES
VDE 0446-5 : 1996 INSULATORS FOR OVERHEAD LINES WITH A NOMINAL VOLTAGE ABOVE 1000 V - CERAMIC OR GLASS INSULATOR UNITS FOR DC SYSTEMS - DEFINITIONS, TEST METHODS AND ACCEPTANCE CRITERIA
DIN EN 61325 : 1996 INSULATORS FOR OVERHEAD LINES WITH A NOMINAL VOLTAGE ABOVE 1000 V - CERAMIC OR GLASS INSULATOR UNITS FOR D.C. SYSTEMS - DEFINITIONS, TEST METHODS AND ACCEPTANCE CRITERIA
NF EN 50119 : 2010 AMD 1 2013 RAILWAY APPLICATIONS - FIXED INSTALLATIONS - ELECTRIC TRACTION OVERHEAD CONTACT LINES
BS EN 50123-7-1:2003 Railway applications. Fixed installations. d.c. switchgear. Measurement, control and protection devices for specific use in d.c. traction systems Measurement, control and protection devices for specific use in d.c. traction systems. Application guide
IEEE 4-2013 IEEE Standard for High-Voltage Testing Techniques
BS EN 62217:2013 Polymeric HV insulators for indoor and outdoor use. General definitions, test methods and acceptance criteria
CEI EN 50123-1 : 2003 RAILWAY APPLICATIONS - FIXED INSTALLATIONS - D.C. SWITCHGEAR - PART 1: GENERAL
NF EN 50123-1 : 2004 RAILWAY APPLICATIONS - FIXED INSTALLATIONS - D.C. SWITCHGEAR - PART 1: GENERAL
IEC TS 63014-1:2018 High voltage direct current (HVDC) power transmission - System requirements for DC-side equipment - Part 1: Using line-commutated converters
I.S. EN 62199:2004 BUSHINGS FOR D.C. APPLICATION
IEC 62155:2003 Hollow pressurized and unpressurized ceramic and glass insulators for use in electrical equipment with rated voltages greater than 1 000 V
IEC 62217:2012 Polymeric HV insulators for indoor and outdoor use - General definitions, test methods and acceptance criteria
PD IEC/TS 60815-4:2016 Selection and dimensioning of high-voltage insulators intended for use in polluted conditions Insulators for d.c. systems
BS EN 50123-2:2003 Railway applications. Fixed installations. D.C. switchgear D.C. circuit breakers
BS EN 50119 : 2009 RAILWAY APPLICATIONS - FIXED INSTALLATIONS - ELECTRIC TRACTION OVERHEAD CONTACT LINES
EN IEC/IEEE 65700 : 2018 BUSHINGS FOR DC APPLICATION (IEC/IEEE 65700-19-03:2014)
BS EN 62231:2007 Composite station post insulators for substations with a.c. voltages greater than 1000 V up to 245 kV. Definitions, test methods and acceptance criteria
I.S. EN 62217:2013 POLYMERIC HV INSULATORS FOR INDOOR AND OUTDOOR USE - GENERAL DEFINITIONS, TEST METHODS AND ACCEPTANCE CRITERIA (IEC 62217:2012 (EQV))
I.S. EN 50123-2:2003 RAILWAY APPLICATIONS - FIXED INSTALLATIONS - D.C. SWITCHGEAR - D.C. CIRCUIT BREAKERS
I.S. EN 50123-7-3:2003 RAILWAY APPLICATIONS - FIXED INSTALLATIONS - D.C. SWITCHGEAR - PART 7-3: MEASUREMENT, CONTROL AND PROTECTION DEVICES FOR SPECIFIC USE IN D.C. TRACTION SYSTEMS - ISOLATING VOLTAGE TRANSDUCERS AND OTHER VOLTAGE MEASURING DEVICES
IEC 60913:2013 Railway applications - Fixed installations - Electric traction overhead contact lines
IEC TS 60815-4:2016 Selection and dimensioning of high-voltage insulators intended for use in polluted conditions - Part 4: Insulators for d.c. systems
I.S. EN 62155:2003 HOLLOW PRESSURIZED AND UNPRESSURIZED CERAMIC AND GLASS INSULATORS FOR USE IN ELECTRICAL EQUIPMENT WITH RATED VOLTAGES GREATER THAN 1000 V
IEC TS 60815-1:2008 Selection and dimensioning of high-voltage insulators intended for use in polluted conditions - Part 1: Definitions, information and general principles
IEC 61325:1995 Insulators for overhead lines with a nominal voltage above 1000 V - Ceramic or glass insulator units for d.c. systems - Definitions, test methods and acceptance criteria
I.S. EN 50119:2020 Railway applications - Fixed installations - Electric traction overhead contact lines
IEC 62231:2006 Composite station post insulators for substations with a.c. voltages greater than 1 000 V up to 245 kV - Definitions, test methods and acceptance criteria
IEC 62199:2004 Bushings for d.c. application
EN 50119 : 2009 AMD 1 2013 RAILWAY APPLICATIONS - FIXED INSTALLATIONS - ELECTRIC TRACTION OVERHEAD CONTACT LINES
EN 50123-7-3:2003 Railway applications - Fixed installations - D.C. switchgear - Part 7-3: Measurement, control and protection devices for specific use in d.c. traction systems - Isolating voltage transducers and other voltage measuring devices
UNE-EN 62217:2013 Polymeric HV insulators for indoor and outdoor use - General definitions, test methods and acceptance criteria
02/207434 DC : 0 IEC 60815-2/TS. ED.1.0 - SELECTION AND DIMENSIONING OF HIGH-VOLTAGE INSULATORS FOR POLLUTED CONDITIONS - PART 2: CERAMIC AND GLASS INSULATORS FOR A.C. SYSTEMS
11/30243837 DC : 0 BS EN 62217 - POLYMERIC HV INSULATORS FOR INDOOR AND OUTDOOR USE - GENERAL DEFINITIONS, TEST METHODS AND ACCEPTANCE CRITERIA
02/206482 DC : 0 IEC 60815-1 TS ED.1.0 - SELECTION AND DIMENSIONING OF HIGH-VOLTAGE INSULATORS FOR POLLUTED CONDITIONS - PART 1: DEFINITIONS, INFORMATION AND GENERAL PRINCIPLES
CSA C62155 : 2006 : R2011 HOLLOW PRESSURIZED AND UNPRESSURIZED CERAMIC AND GLASS INSULATORS FOR USE IN ELECTRICAL EQUIPMENT WITH RATED VOLTAGES GREATER THAN 1000 V
CSA C1325 : 1999 : R2011 INSULATORS FOR OVERHEAD LINES WITH A NOMINAL VOLTAGE ABOVE 1000 V - CERAMIC OR GLASS INSULATOR UNITS FOR D.C. SYSTEMS - DEFINITIONS, TEST METHODS AND ACCEPTANCE CRITERIA
IEEE 1277-2010 IEEE Standard General Requirements and Test Code for Dry-Type and Oil-Immersed Smoothing Reactors for DC Power Transmission
I.S. EN IEC/IEEE 65700:2018 BUSHINGS FOR DC APPLICATION
EN 50123-7-1:2003 Railway applications - Fixed installations - D.C. switchgear - Part 7-1: Measurement, control and protection devices for specific use in d.c. traction systems - Application guide
EN 50123-1:2003 Railway applications - Fixed installations - D.C. switchgear - Part 1: General
EN 50123-4:2003/A1:2013 RAILWAY APPLICATIONS - FIXED INSTALLATIONS - D.C. SWITCHGEAR - PART 4: OUTDOOR D.C. DISCONNECTORS, SWITCH-DISCONNECTORS AND EARTHING SWITCHES
EN 61325 : 1995 Insulators for overhead lines with a nominal voltage above 1 kV - Ceramic or glass insulator units for d.c. systems - Definitions, test methods and acceptance criteria
EN 50123-2:2003 Railway applications - Fixed installations - D.C. switchgear - Part 2: D.C. circuit breakers
EN 62217:2013 Polymeric HV insulators for indoor and outdoor use - General definitions, test methods and acceptance criteria
EN 50123-3:2003/A1:2013 RAILWAY APPLICATIONS - FIXED INSTALLATIONS - D.C. SWITCHGEAR - PART 3: INDOOR D.C. DISCONNECTORS, SWITCH-DISCONNECTORS AND EARTHING SWITCHES

IEC 60060-2:2010 High-voltage test techniques - Part 2: Measuring systems
AS 61869.14:2021 Instrument transformers Additional requirements for current transformers for DC applications (IEC 61869-14:2018 (ED 1.0) MOD)
IEC 60060-1:2010 High-voltage test techniques - Part 1: General definitions and test requirements
IEC 60507:2013 Artificial pollution tests on high-voltage ceramic and glass insulators to be used on a.c. systems
IEC TS 60815-1:2008 Selection and dimensioning of high-voltage insulators intended for use in polluted conditions - Part 1: Definitions, information and general principles

View more information