1 Overview
  1.1 Scope
  1.2 Purpose
  1.3 Application
2 Normative references
3 Definitions
  3.1 General terminology
  3.2 Technical terminology
4 Preliminary procedures
  4.1 Background
  4.2 Test plan
  4.3 Calibration
  4.4 Reference level and dynamic range
  4.5 Preliminary shield check procedures
  4.6 Test/witness personnel
5 Detailed procedures
  5.1 Background
  5.2 Recommended standard measurement frequencies
  5.3 Pass/fail requirements
  5.4 Shielding effectiveness calculation
  5.5 Preparation procedures
  5.6 Low-frequency measurements (9 kHz to 20 MHz)
  5.7 Resonant range measurements (20 MHz to 300 MHz)
  5.8 High-frequency measurements (300 MHz to 18 GHz)
6 Quality assurance technical report
  6.1 Abbreviated test report
  6.2 Full test report
Annex A (informative) Rationale
      A.1 Basis
      A.2 Considerations pertinent to the objectives of 1.2
      A.3 Cavity resonances
      A.4 Measurement locations
      A.5 Measurement equipment
Annex B (informative) Mathematical formulas
      B.1 Specific mathematical formulations
      B.2 Low-range (50 Hz to 20 MHz) shielding effectiveness
      B.3 Resonant range (20 MHz to 300 MHz) shielding effectiveness
      B.4 High-range (300 MHz to 100 GHz) shielding effectiveness
      B.5 Nonlinear (logarithmic) calculations
      B.6 Dynamic range considerations
Annex C (informative) Miscellaneous supporting information
      C.1 Coplanar versus coaxial loops
      C.2 Nonlinearity of high-permeability ferromagnetic enclosures
      C.3 Selecting measurement frequencies
Annex D (informative) Guidelines for the selection of measurement
        techniques
      D.1 Types of enclosures
      D.2 Performance requirements
      D.3 Equipment requirements
      D.4 Regulatory agency conflicts
Annex E (informative) Preliminary measurements and repairs
      E.1 Background
      E.2 Frequencies for preliminary check
      E.3 Preliminary check procedures

This standard provides uniform measurement procedures for determining the effectiveness of electromagnetic (EM) shielding enclosures at frequencies from 9 kHz to 18 GHz (extendable down to 50 Hz and up to 100 GHz).

Committee
Standards Development Committee
DevelopmentNote
Supersedes MIL STD 285 (04/2006) Supersedes IEEE DRAFT 299. (03/2007)
DocumentType
Standard
ISBN
978-0-7381-5216-5
Pages
52
PublisherName
Institute of Electrical & Electronics Engineers
Status
Withdrawn
Supersedes

IEEE 1302-2008 IEEE Guide for the Electromagnetic Characterization of Conductive Gaskets in the Frequency Range of DC to 18 GHz
14/30316052 DC : 0 BS EN 61000-4-23 ED 2.0 - ELECTROMAGNETIC COMPATIBILITY (EMC) - PART 4-23: TESTING AND MEASUREMENT TECHNIQUES - TEST METHODS FOR PROTECTIVE DEVICES FOR HEMP AND OTHER RADIATED DISTURBANCES
IEEE DRAFT 1302 : D4.1 FEB 97 GUIDE FOR THE ELECTROMAGNETIC CHARACTERIZATION OF CONDUCTIVE GASKETS IN THE FREQUENCY RANGE DC TO 18 GHZ
DSCC 86129 : B GASKETS, SHIELDING, EMI/RFI, WIRE MESH, RESILIENT, STRIPS WITH ROUND CROSS SECTION
AECTP-500 : 2016 ELECTROMAGNETIC ENVIRONMENTAL EFFECTS TESTS AND VERIFICATION
IEC 61000-4-23:2016 Electromagnetic compatibility (EMC) - Part 4-23: Testing and measurement techniques - Test methods for protective devices for HEMP and other radiated disturbances
DEFSTAN 59-188(PT2)/1(2010) : 2010 HIGH ALTITUDE ELECTROMAGNETIC PULSE (HEMP) PROTECTION FOR GROUND BASED COMMUNICATION FACILITIES PERFORMING CRITICAL, TIME-URGENT MISSIONS - PART 2: TRANSPORTABLE AND MOBILE SYSTEMS
DEFSTAN 59-188(PT2)/2(2017) : 2017 HIGH ALTITUDE ELECTROMAGNETIC PULSE (HEMP) PROTECTION FOR GROUND BASED COMMUNICATION FACILITIES PERFORMING CRITICAL, TIME-URGENT MISSIONS - PART 2: TRANSPORTABLE AND MOBILE SYSTEMS
IEEE 2715-2023 IEEE Guide for the Characterization of the Shielding Effectiveness of Planar Materials
IEEE 2716-2022 IEEE Guide for the Characterization of the Effectiveness of Printed Circuit Board Level Shielding
DSCC 90046 : E GASKETS, SHIELDING, EMI/RFI, ORIENTED WIRES IN SILICONE RUBBER
MIL-STD-1678-3 Revision C:2016 FIBER OPTIC CABLING SYSTEMS REQUIREMENTS AND MEASUREMENTS - PART 3: PHYSICAL, MECHANICAL, ENVIRONMENTAL AND MATERIAL MEASUREMENTS (PART 3 OF 6 PARTS)
MIL-DTL-83526-21 Revision C:2014 Connector, Fiber Optic, Circular Hermaphroditic, Bulkhead, Low Profile without Strain Relief, Jam-Nut Mount, 2 and 4 Positions, Expanded Beam
MIL-DTL-83528 Revision H:2018 Gasketing Material, Conductive, Shielding Gasket, Electronic, Elastomer, EMI/RFI, General Specification for
MIL-DTL-83526-20 Revision C:2014 Connector, Fiber Optic Plug, Circular Hermaphroditic, In-Line Mount, 2 and 4 Positions, Expanded Beam
MIL-DTL-83526 Revision D:2014 CONNECTORS, FIBER OPTIC, CIRCULAR, ENVIRONMENTAL RESISTANT, HERMAPHRODITIC, GENERAL SPECIFICATION FOR
ASTM F 3057 : 2016 : REDLINE Standard Test Method for Electromagnetic Shielding Effectiveness of Glazings
IEEE 299.1-2013 IEEE Standard Method for Measuring the Shielding Effectiveness of Enclosures and Boxes Having all Dimensions between 0.1 m and 2 m
ASTM E 1851 : 2015 : REDLINE Standard Test Method for Electromagnetic Shielding Effectiveness of Durable Rigid Wall Relocatable Structures
TR 102 495-1 : 1.1.1 ELECTROMAGNETIC COMPATIBILITY AND RADIO SPECTRUM MATTERS (ERM); SHORT RANGE DEVICES (SRD); TECHNICAL CHARACTERISTICS FOR SRD EQUIPMENT USING ULTRA WIDE BAND SENSOR TECHNOLOGY (UWB); SYSTEM REFERENCE DOCUMENT PART 1: BUILDING MATERIAL ANALYSIS AND CLASSIFICATION APPLICATIONS OPERATING IN THE FREQUENCY BAND FROM 2,2 GHZ TO 8 GHZ
IEEE/ANSI C63.15-2010 American National Standard Recommended Practice for the Immunity Measurement of Electrical and Electronic Equipment
NASA KSC SPEC E 0002 : 2010 MODULAR ELECTRICAL ENCLOSURES, RACKS, CONSOLES, AND ACCESSORIES, SPECIFICATION FOR
AEP-18 : 1988 THE NATO USERS GUIDE TO EMP TESTING AND SIMULATION
IEEE 1642-2015 IEEE Recommended Practice for Protecting Publicly Accessible Computer Systems from Intentional Electromagnetic Interference (IEMI)
IEEE DRAFT C63.19 : 2005 METHODS OF MEASUREMENT OF COMPATIBILITY BETWEEN WIRELESS COMMUNICATIONS DEVICES AND HEARING AIDS
DSCC 90095 : B SHIELDING TAPE, EMI, KNITTED WIRE MESH
AEP-41 VOL 6 : 2014 NATO IMPLEMENTATION OF UNIFIED PROTECTION AGAINST ELECTROMAGNETIC ENVIRONMENTAL EFFECTS (UE[3])
MIL-PRF-28876 Revision E:2004 Connectors, Fiber Optic, Circular, Plug and Receptacle Style, Multiple Removable Termini, General Specification for
MIL-PRF-22885-56 Revision H:2006 SWITCH, PUSH BUTTON, ILLUMINATED, 2PDT, 4PDT, AND INDICATOR ASSEMBLIES, 4-LAMP, SOLID MOUNTING
IEEE/ANSI C63.19-2011 REDLINE American National Standard Methods of Measurement of Compatibility between Wireless Communications Devices and Hearing Aids
MIL-PRF-44408 Revision C:1996 SHELTER, ELECTRICAL EQUIPMENT, LIGHTWEIGHT
ANEP-45 : 0
IEEE/ANSI C63.9-2008 American National Standard for RF Immunity of Audio Office Equipment to General Use Transmitting Devices with Transmitter Power Levels up to 8 Watts
IEEE 1560-2005 IEEE Standard for Methods of Measurement of Radio Frequency Power Line Interference Filter in the Range of 100 Hz to 10 GHz
IEEE 1302-2019 REDLINE IEEE Guide for the Electromagnetic Characterization of Conductive Gaskets in the Frequency Range of DC to 40 GHz

ISO/IEC 17025:2005 General requirements for the competence of testing and calibration laboratories
IEEE 473-1985 IEEE Recommended Practice for an Electromagnetic Site Survey (10 kHz to 10 GHz)
IEEE 291-1991 IEEE Standard Methods for Measuring Electromagnetic Field Strength of Sinusoidal Continuous Waves, 30 Hz to 30 GHz
IEEE C63.2-2009 American National Standard for Electromagnetic Noise and Field Strength Instrumentation, 10 Hz to 40 GHz Specifications
IEEE C95.1-2005 IEEE Standard for Safety Levels with Respect to Human Exposure to Radio Frequency Electromagnetic Fields, 3 kHz to 300 GHz

View more information
US$130.68
Excluding Tax where applicable

Access your standards online with a subscription

Features

  • Simple online access to standards, technical information and regulations.

  • Critical updates of standards and customisable alerts and notifications.

  • Multi-user online standards collection: secure, flexible and cost effective.