• There are no items in your cart

IEEE 762-2006

Superseded
Superseded

A superseded Standard is one, which is fully replaced by another Standard, which is a new edition of the same Standard.

View Superseded by
superseded

A superseded Standard is one, which is fully replaced by another Standard, which is a new edition of the same Standard.

IEEE Standard Definitions for Use in Reporting Electric Generating Unit Reliability, Availability, and Productivity
Available format(s)

PDF

Superseded date

08-15-2023

Language(s)

English

Published date

03-15-2007

1 Overview
   1.1 Scope
   1.2 Purpose
2 Normative references
3 Definitions
4 Unit states
   4.1 Active
   4.2 Deactivated shutdown
5 Capacity terms
   5.1 Maximum capacity (MC)
   5.2 Dependable capacity
   5.3 Available capacity
   5.4 Seasonal derating
   5.5 Unit derating
   5.6 Planned derating
   5.7 Unplanned derating
   5.8 Installed nameplate capacity
6 Time designations and dates
   6.1 Total hours (TH)
   6.2 Period hours (PH) or active hours (ACTH)
   6.3 Deactivated shutdown hours (DSH)
   6.4 Available hours (AH)
   6.5 Service hours (SH)
   6.6 Reserve shutdown hours (RSH)
   6.7 Unavailable hours (UH)
   6.8 Planned outage hours (POH)
   6.9 Unplanned outage hours (UOH)
   6.10 Forced outage hours (FOH)
   6.11 Maintenance outage hours (MOH)
   6.12 Unit derated hours (UNDH)
   6.13 Planned derated hours (PDH)
   6.14 Unplanned derated hours (UDH)
   6.15 Forced derated hours (FDH)
   6.16 Maintenance derated hours (MDH)
   6.17 Seasonal derated hours (SDH)
   6.18 Equivalent hours (E)
   6.19 Service date (SD)
   6.20 Deactivation date
   6.21 Reactivation date
7 Energy terms
   7.1 Actual generation (AAG)
   7.2 Maximum generation (MG)
   7.3 Available generation (AG)
   7.4 Unavailable generation (UG)
   7.5 Seasonal unavailable generation (SUG)
   7.6 Reserve generation (RG)
   7.7 Derated generation (DG)
8 Performance indexes of an individual unit
   8.1 Planned outage factor (POF)
   8.2 Unplanned outage factor (UOF)
   8.3 Forced outage factor (FOF)
   8.4 Maintenance outage factor (MOF)
   8.5 Unavailability factor (UF)
   8.6 Availability factor (AF)
   8.7 Service factor (SF)
   8.8 Seasonal derating factor (SDF)
   8.9 Unit derating factor (UDF)
   8.10 Equivalent unavailability factor (EUF)
   8.11 Equivalent availability factor (EAF)
   8.12 Gross capacity factor (GCF)
   8.13 Net capacity factor (NCF)
   8.14 Gross output factor (GOF)
   8.15 Net output factor (NOF)
   8.16 Forced outage rate (FOR)
   8.17 Equivalent forced outage rate (EFOR)
   8.18 Equivalent planned outage factor (EPOF)
   8.19 Equivalent unplanned outage factor (EUOF)
   8.20 Equivalent forced outage factor (EFOF)
   8.21 Equivalent maintenance outage factor (EMOF)
   8.22 Mean service time to outage
   8.23 Mean outage duration
   8.24 Starting reliability (SR)
   8.25 Cycling rate (CR) or average run time (ART)
9 Unweighted (time-based) calculations for group performance
   indexes
   9.1 Planned outage factor (POF)
   9.2 Unplanned outage factor (UOF)
   9.3 Forced outage factor (FOF)
   9.4 Maintenance outage factor (MOF)
   9.5 Unavailability factor (UF)
   9.6 Availability factor (AF)
   9.7 Service factor (SF)
   9.8 Seasonal derating factor (SDF)
   9.9 Unit derating factor (UDF)
   9.10 Equivalent unavailability factor (EUF)
   9.11 Equivalent availability factor (EAF)
   9.12 Gross capacity factor (GCF)
   9.13 Net capacity factor (NCF)
   9.14 Gross output factor (GOF)
   9.15 Net output factor (NOF)
   9.16 Forced outage rate (FOR)
   9.17 Equivalent forced outage rate (EFOR)
   9.18 Equivalent planned outage factor (EPOF)
   9.19 Equivalent unplanned outage factor (EUOF)
   9.20 Equivalent forced outage factor (EFOF)
   9.21 Equivalent maintenance outage factor (EMOF)
   9.22 Starting reliability (SR)
   9.23 Cycling rate (CR) or average run time (ART)
10 Capacity-weighted calculations for group performance indexes
   10.1 Weighted planned outage factor (WPOF)
   10.2 Weighted unplanned outage factor (WUOF)
   10.3 Weighted forced outage factor (WFOF)
   10.4 Weighted maintenance outage factor (WMOF)
   10.5 Weighted unavailability factor (WUF)
   10.6 Weighted availability factor (WAF)
   10.7 Weighted service factor (WSF)
   10.8 Weighted seasonal derating factor (WSDF)
   10.9 Weighted unit derating factor (WUDF)
   10.10 Weighted equivalent unavailability factor (WEUF)
   10.11 Weighted equivalent availability factor (WEAF)
   10.12 Gross capacity factor (GCF)
   10.13 Net capacity factor (NCF)
   10.14 Gross output factor (GOF)
   10.15 Net output factor (NOF)
   10.16 Weighted forced outage rate (WFOR)
   10.17 Weighted equivalent forced outage rate (WEFOR)
   10.18 Weighted equivalent planned outage factor (WEPOF)
   10.19 Weighted equivalent unplanned outage factor (WEUOF)
   10.20 Weighted equivalent forced outage factor (WEFOF)
   10.21 Weighted equivalent maintenance outage factor (WEMOF)
Annex A (informative) Correlation between unit state and capacity
        derating definitions
Annex B (informative) Transitions between active states
Annex C (informative) Relationships between period-hour-based
        performance indexes
Annex D (informative) Outside plant management control
Annex E (informative) Glossary of terms and abbreviations
Annex F (informative) Pooling methodologies for EFOR[d]
      F.1 Unweighted pooling
      F.2 Capacity-weighted pooling
Annex G (informative) Limiting conditions for forced outage indexes
Annex H (informative) Bibliography

This document standardizes terminology and indexes for reporting electric generating unit reliability, availability, and productivity performance measures while recognizing the power industry's needs, including marketplace competition.

Committee
Analytic Methods for Power Systems
DevelopmentNote
Supersedes IEEE DRAFT 762. (03/2007)
DocumentType
Standard
ISBN
978-0-7381-5226-4
Pages
78
PublisherName
Institute of Electrical & Electronics Engineers
Status
Superseded
SupersededBy
Supersedes

IEEE 1240-2000 IEEE Guide for the Evaluation of the Reliability of HVDC Converter Stations
MIL-HDBK-470 Revision A:1997 DESIGNING AND DEVELOPING MAINTAINABLE PRODUCTS AND SYSTEMS - VOLUME 1
CLC/TS 61400-26-3:2017 Wind energy generation systems - Part 26-3: Availability for wind power stations
IEEE DRAFT 1147 : D8 2005 GUIDE FOR THE REHABILITATION OF HYDROELECTRIC POWER PLANTS
14/30244780 DC : 0 BS ISO 19859 - GAS TURBINE APPLICATIONS - REQUIREMENTS FOR POWER GENERATION
CLC/TS 61400-26-1:2017 Wind turbines - Part 26-1: Time-based availability for wind turbine generating systems
PD CLC/TS 61400-26-2:2017 Wind turbines Production-based availability for wind turbines
ISO 19859:2016 Gas turbine applications Requirements for power generation
IEC TS 61400-26-2:2014 Wind turbines - Part 26-2: Production-based availability for wind turbines
CLC/TS 61400-26-2:2017 Wind turbines - Part 26-2: Production-based availability for wind turbines
PD CLC/TS 61400-26-1:2017 Wind turbines Time-based availability for wind turbine generating systems
BS PD IEC TS 61400-26-2 : 2014 WIND TURBINES - PART 26-2: PRODUCTION-BASED AVAILABILITY FOR WIND TURBINES
NF ISO 19859 : 2016 GAS TURBINE APPLICATIONS - REQUIREMENTS FOR POWER GENERATION
IEC TS 61400-26-1:2011 Wind turbines - Part 26-1: Time-based availability for wind turbine generating systems
S.R. CLC/TS 61400-26-1:2017 WIND TURBINES - PART 26-1: TIME-BASED AVAILABILITY FOR WIND TURBINE GENERATING SYSTEMS
IEEE 1147-2005 IEEE Guide for the Rehabilitation of Hydroelectric Power Plants
BS ISO 19859:2016 Gas turbine applications. Requirements for power generation
IEC TS 61400-26-3:2016 Wind energy generation systems - Part 26-3: Availability for wind power stations
PD CLC/TS 61400-26-3:2017 Wind energy generation systems Availability for wind power stations
DD IEC TS 61400-26-1 : 2011 WIND TURBINES - PART 26-1: TIME-BASED AVAILABILITY FOR WIND TURBINE GENERATING SYSTEMS
PD IEC/TS 61400-26-3:2016 Wind energy generation systems Availability for wind power stations
S.R. CLC/TS 61400-26-2:2017 WIND TURBINES - PART 26-2: PRODUCTION-BASED AVAILABILITY FOR WIND TURBINES
S.R. CLC/TS 61400-26-3:2017 WIND ENERGY GENERATION SYSTEMS - PART 26-3: AVAILABILITY FOR WIND POWER STATIONS

View more information
US$130.68
Excluding Tax where applicable

Access your standards online with a subscription

Features

  • Simple online access to standards, technical information and regulations.

  • Critical updates of standards and customisable alerts and notifications.

  • Multi-user online standards collection: secure, flexible and cost effective.