IEEE Standard for Ventilated Dry- Type Power Transformers, 501 kVA and Larger, Three-Phase, with High- Voltage 601 V to 34 500 V; Low- Voltage 208Y/120 V to 4160 V- General Requirements

Available format(s)

PDF

Superseded date

09-09-2019

Language(s)

English

Published date

03-09-2009

1 Overview
   1.1 Scope
   1.2 Purpose
2 Normative references
3 Definitions
4 Usual service conditions
5 Ratings and characteristics
   5.1 Kilovolt-ampere ratings
   5.2 Kilovolt-ampere and voltage ratings
   5.3 Taps
   5.4 Insulation levels
   5.5 Angular displacement and terminal markings
   5.6 Percent impedance voltage
6 Construction
   6.1 Insulation system
   6.2 Accessory location
   6.3 Nameplate
   6.4 Transformer connections
   6.5 Tap changing
   6.6 Lifting, jacking, and moving facilities
   6.7 Ground pad
   6.8 Transformer enclosure
7 Routine tests
8 Tolerances
9 Other ratings and characteristics
   9.1 Forced-air-cooled ratings
   9.2 40 Degree C average ambient temperature conditions
   9.3 Other winding temperature rises
   9.4 Other temperature class insulation systems
   9.5 Other high-voltage ratings and connections
   9.6 Y-Y connected transformers
   9.7 Increased neutral insulation
   9.8 Other basic lightning impulse insulation levels
10 Other construction
   10.1 High-voltage connection arrangements
   10.2 Low-voltage connection arrangements
   10.3 Surge arresters
   10.4 Unit substation application
   10.5 Temperature devices
   10.6 Forced-air cooling
   10.7 Provision for future forced-air cooling
   10.8 Space heaters
   10.9 Current transformers (or provision for their addition
         in the future)
   10.10 Terminal blocks
   10.11 Contacts
11 Other tests
Annex A (informative) Bibliography

Presents characteristics relating to performance, limited electrical and mechanical interchangeability, as well as safety of the equipment described, and to assist in the proper selection of such equipment.

Committee
Transformers
DevelopmentNote
Supersedes ANSI C57.12.51. (01/2011)
DocumentType
Standard
Pages
30
PublisherName
Institute of Electrical & Electronics Engineers
Status
Superseded
SupersededBy
Supersedes

NEMA TR1 : 2013 TRANSFORMERS, STEP VOLTAGE REGULATORS AND REACTORS
UFC 3-550-01 : CHANGE 1 UNIFIED FACILITIES CRITERIA - EXTERIOR ELECTRICAL POWER DISTRIBUTION
IEEE 3001.5-2013 IEEE Recommended Practice for the Application of Power Distribution Apparatus in Industrial and Commercial Power Systems
IEEE C37.121-2012 GUIDE FOR SWITCHGEAR - UNIT SUBSTATION - REQUIREMENTS
IEEE C57.12.70-2011 IEEE Standard for Standard Terminal Markings and Connections for Distribution and Power Transformers
IEEE C37.121-2012 REDLINE IEEE Guide for Switchgear - Unit Substation - Requirements

IEEE C57.12.01-2015 REDLINE IEEE Standard for General Requirements for Dry-Type Distribution and Power Transformers
IEEE C57.12.01-2005 IEEE Standard General Requirements for Dry-Type Distribution and Power Transformers Including Those with Solid Cast and/or Resin Encapsulated Windings
ANSI C84.1 : 2016 ELECTRIC POWER SYSTEMS AND EQUIPMENT - VOLTAGE RATINGS (60 HERTZ)
IEEE C57.12.70-2011 IEEE Standard for Standard Terminal Markings and Connections for Distribution and Power Transformers
IEEE C57.12.91-2011 IEEE Standard Test Code for Dry-Type Distribution and Power Transformers
IEEE C57.94-1982 IEEE Recommended Practice for Installation, Application, Operation, and Maintenance of Dry-Type General Purpose Distribution and Power Transformers
IEEE C57.12.50 : 1981 REQUIREMENTS FOR VENTILATED DRY-TYPE DISTRIBUTION TRANSFORMERS, 1 TO 500 KVA, SINGLE-PHASE, AND 15 TO 500 KVA, THREE-PHASE, WITH HIGH-VOLTAGE 601 TO 34500 VOLTS, LOW-VOLTAGE 120 TO 600 VOLTS
IEEE C57.13-2008 IEEE Standard Requirements for Instrument Transformers
IEEE C57.105-1978 IEEE Guide for Application of Transformer Connections in Three-Phase Distribution Systems
ANSI C57.12.57 : 1987 AMERICAN NATIONAL STANDARD FOR TRANSFORMERS - VENTILATED DRY-TYPE NETWORK TRANSFORMERS 2500 KVA AND BELOW, THREE-PHASE, WITH HIGH-VOLTAGE 34500 VOLTS AND BELOW, LOW-VOLTAGE 216Y/125 AND 480Y/227 VOLTS - REQUIREMENTS

View more information
US$103.36
Excluding Tax where applicable

Access your standards online with a subscription

Features

  • Simple online access to standards, technical information and regulations.

  • Critical updates of standards and customisable alerts and notifications.

  • Multi-user online standards collection: secure, flexible and cost effective.