• There are no items in your cart

IEEE DRAFT 404 : D13 2006

Withdrawn
Withdrawn

A Withdrawn Standard is one, which is removed from sale, and its unique number can no longer be used. The Standard can be withdrawn and not replaced, or it can be withdrawn and replaced by a Standard with a different number.

View Superseded by
withdrawn

A Withdrawn Standard is one, which is removed from sale, and its unique number can no longer be used. The Standard can be withdrawn and not replaced, or it can be withdrawn and replaced by a Standard with a different number.

EXTRUDED AND LAMINATED DIELECTRIC SHIELDED CABLE JOINTS RATED 2500 V - 500 000 V
Withdrawn date

10-17-2023

Published date

01-12-2013

1 Scope
2 Normative References
3 Definitions
  3.1 Cable joint categories
  3.2 Joint constructions
  3.3 Other terms
4 Service conditions
5 Ratings
  5.1 Voltage
  5.2 Current and Temperature
6 Construction
  6.1 Identification
  6.2 Shielding
  6.3 Sheath/shield sectional
7 Testing
  7.1 Production tests for premolded and single-component
       cold-shrink joints
  7.2 Fingerprint tests for heat-shrink and multi-component
       cold-shrink joint components
  7.3 Fingerprint tests for elastomeric taped-joint components
  7.4 Design tests and testing sequence for all joint types
  7.5 Design test conditions
  7.6 Dielectric integrity tests
  7.7 Voltage Withstand tests
  7.8 Short-time current test
  7.9 Cyclic aging test for extruded dielectric and transition
       joints
  7.10 High-voltage time test
  7.11 Sectionalizer tests
  7.12 Semiconducting shielding test
  7.13 Cable metallic-shield restoration and cable jacket
       restoration components
  7.14 Connector thermal and mechanical tests
Annexes
Annex A: (Informative) Typical values of heat-shrinkable and
         multi-component cold-shrink joint component tests
         and sampling rates
Annex B: (Informative) Typical values of elastomeric taped-joint
         component tests and sampling rates
Annex C: (Informative) Bibliography

Lays down electrical ratings and test requirements of cable joints used with extruded and laminated dielectric shielded cables rated in preferred voltage steps from 2500 V to 500 000 V. In addition, it defines test requirements for cable jacket and cable shield restoration devices.

DocumentType
Draft
PublisherName
Institute of Electrical & Electronics Engineers
Status
Withdrawn
SupersededBy

ASTM D 4325 : 2013 : REDLINE Standard Test Methods for Nonmetallic Semi-Conducting and Electrically Insulating Rubber Tapes
ASTM D 4496 : 2013 Standard Test Method for D-C Resistance or Conductance of Moderately Conductive Materials
ASTM D 4388 : 2013 Standard Specification for Nonmetallic Semi-Conducting and Electrically Insulating Rubber Tapes
IEC 60502-4:2010 Power cables with extruded insulation and their accessories for rated voltages from 1 kV (U<sub>m</sub> = 1,2 kV) up to 30 kV (U<sub>m</sub> = 36 kV) - Part 4: Test requirements on accessories for cables with rated voltages from 6 kV (U<sub>m</sub> = 7,2 kV) up to 30 kV (U<sub>m</sub> = 36 kV)
IEEE 592-2007 REDLINE IEEE Standard for Exposed Semiconducting Shields on High-Voltage Cable Joints and Separable Connectors
WC 5-1992 THERMOPLASTIC-INSULATED WIRE AND CABLE FOR THE TRANSMISSION AND DISTRIBUTION OF ELECTRICAL ENERGY
IEEE 82 : 2002 TEST PROCEDURE FOR IMPULSE VOLTAGE TESTS ON INSULATED CONDUCTORS
WC 8:1988 ETHYLENE-PROPYLENE-RUBBER-INSULATED WIRE AND CABLE FOR THE TRANSMISSION AND DISTRIBUTION OF ELECTRICAL ENERGY
ICEA P 32 382 : 2007(R2018) SHORT CIRCUIT CHARACTERISTICS OF INSULATED CABLES
WC 4-1988/ICEA S-65-375 3rd Ed. (R1993) VARNISHED-CLOTH-INSULATED WIRE AND CABLE FOR THE TRANSMISSION AND DISTRIBUTION OF ELECTRICAL ENERGY
IEEE 4-2013 IEEE Standard for High-Voltage Testing Techniques
ICEA S 94 649 : 2013 CONCENTRIC NEUTRAL CABLES RATED 5 THROUGH 46 KV
IEEE C37.09-1999 IEEE Standard Test Procedure for AC High-Voltage Circuit Breakers Rated on a Symmetrical Current Basis
WC 3-1992 RUBBER-INSULATED WIRE AND CABLE FOR THE TRANSMISSION AND DISTRIBUTION OF ELECTRICAL ENERGY
ICEA S 97 682 : 2013 UTILITY SHIELDED POWER CABLES RATED 5 THROUGH 46 KV
IEEE 575-2014 IEEE Guide for Bonding Shields and Sheaths of Single-Conductor Power Cables Rated 5 kV through 500 kV
WC 7-1988 CROSS-LINKED-THERMOSETTING-POLYETHYLENE-INSULATED WIRE AND CABLE FOR THE TRANSMISSION AND DISTRIBUTION OF ELECTRICAL ENERGY

View more information
Sorry this product is not available in your region.

Access your standards online with a subscription

Features

  • Simple online access to standards, technical information and regulations.

  • Critical updates of standards and customisable alerts and notifications.

  • Multi-user online standards collection: secure, flexible and cost effective.