ISO 1264:1980
Current
The latest, up-to-date edition.
Plastics Homopolymer and copolymer resins of vinyl chloride Determination of pH of aqueous extract
Hardcopy , PDF , PDF 3 Users , PDF 5 Users , PDF 9 Users
English, French
11-01-1980
Treatment of a test portion of resin with a given volume of an aqueous solution of sodium chloride previous neutralized to pH 7,0. After stirring and decanting, measurement of the potential difference existing between a glass electrode and a reference calomel electrode immersed in the liquid maintained at 23 C and reading of this difference, expressed in pH units directly on th pH meter scale.