• ISO 13253:2017

    Current The latest, up-to-date edition.
    Add to Watchlist
    This Standard has been added successfully to your Watchlist.
    Please visit My Watchlist to see all standards that you are watching.
    Please log in or to add this standard to your Watchlist.
    We could not add this standard to your Watchlist.
    Please retry or contact support for assistance.
    We could not add this standard to your Watchlist.
    Please retry or contact support for assistance.
    You have already added this standard to your Watchlist.
    Visit My Watchlist to view the full list.

    Ducted air-conditioners and air-to-air heat pumps — Testing and rating for performance

    Available format(s):  Hardcopy, PDF, PDF 3 Users, PDF 5 Users, PDF 9 Users

    Language(s):  English

    Published date:  07-18-2017

    Publisher:  International Organization for Standardization

    Add to Watchlist

    Add To Cart

    Abstract - (Show below) - (Hide below)

    ISO 13253:2017 specifies performance testing, the standard conditions and the test methods for determining the capacity and efficiency ratings of air-cooled, air-conditioners and air-to-air heat pumps.

    ISO 13253:2017 is applicable to the following equipment:

    - ducted air-cooled air conditioners and ducted air to air heat pumps.

    ISO 13253:2017 is limited to

    - residential, commercial and industrial single-package, and split-system air conditioners and heat pumps,

    - factory-made, electrically driven and use mechanical compression,

    - utilizing single, multiple and variable capacity components, and

    - multiple split-system utilizing one or more refrigeration systems, one outdoor unit and one or more indoor units, controlled by a single thermostat/controller.

    The requirements of testing and rating contained in this document are based on the use of matched assemblies.

    ISO 13253:2017 is not applicable to the rating and testing of the following:

    a) water-source heat pumps or water-cooled air-conditioners;

    b) multi-split-system air-conditioners and air-to-air heat pumps (see ISO 15042 for testing of such equipment);

    c) mobile (windowless) units having a condenser exhaust duct;

    d) individual assemblies not constituting a complete refrigeration system;

    e) equipment using the absorption refrigeration cycle;

    f) non-ducted equipment (see ISO 5151 for testing of such equipment);

    g) ducted air conditioners and/or ducted heat pumps, rated at less than 8 kW and intended to operate at external static pressures of less than 25 Pa, controlled by a single thermostat/controller (refer to ISO 5151).

    ISO 13253:2017 does not cover the determination of seasonal efficiencies, which can be required in some countries because they provide a better indication of efficiency under actual operating conditions.

    NOTE Throughout this document, the terms "equipment" and "systems" mean "air-conditioners" and/or "heat pumps".

    General Product Information - (Show below) - (Hide below)

    Development Note Supersedes ISO/DIS 13253. (07/2017) NEW CHILD AMD 1 IS NOW ADDED
    Document Type Standard
    Product Note NEW CHILD AMD 1 IS NOW ADDED
    Publisher International Organization for Standardization
    Status Current
    Supersedes

    Standards Referenced By This Book - (Show below) - (Hide below)

    ANSI/AHRI/ASHRAE ISO 13256-2 : 1998 : R2012 WATER-SOURCE HEAT PUMPS - TESTING AND RATING FOR PERFORMANCE - PART 2: WATER-TO-WATER AND BRINE-TO-WATER HEAT PUMPS
    PD CEN ISO/TS 16491:2012 (published 2013-01) Guidelines for the evaluation of uncertainty of measurement in air conditioner and heat pump cooling and heating capacity tests
    15/30284307 DC : 0 BS ISO 5151 - NON-DUCTED AIR CONDITIONERS AND HEAT PUMPS - TESTING AND RATING FOR PERFORMANCE
    12/30234071 DC : 0 BS ISO 16358-3 - AIR-COOLED AIR CONDITIONERS AND AIR-TO-AIR HEAT PUMPS - TESTING AND CALCULATING METHODS FOR SEASONAL PERFORMANCE FACTORS - PART 3: ANNUAL PERFORMANCE FACTOR
    BS ISO 13380:2002 CONDITION MONITORING AND DIAGNOSTICS OF MACHINES - GENERAL GUIDELINES ON USING PERFORMANCE PARAMETERS
    ISO 15042:2017 Multiple split-system air conditioners and air-to-air heat pumps — Testing and rating for performance
    CSA C748 : 2013 PERFORMANCE OF DIRECT-EXPANSION (DX) GROUND-SOURCE HEAT PUMPS
    ISO 16358-3:2013 Air-cooled air conditioners and air-to-air heat pumps Testing and calculating methods for seasonal performance factors Part 3: Annual performance factor
    IEC 60335-2-40:2018 Household and similar electrical appliances - Safety - Part 2-40: Particular requirements for electrical heat pumps, air-conditioners and dehumidifiers
    IEC 60335-2-40:2018 RLV Household and similar electrical appliances - Safety - Part 2-40: Particular requirements for electrical heat pumps, air-conditioners and dehumidifiers
    CEN ISO/TS 16491 : 2012 GUIDELINES FOR THE EVALUATION OF UNCERTAINTY OF MEASUREMENT IN AIR CONDITIONER AND HEAT PUMP COOLING AND HEATING CAPACITY TESTS (ISO/TS 16491:2012)
    12/30234064 DC : 0 BS ISO 16358-1 - AIR-COOLED AIR CONDITIONERS AND AIR-TO-AIR HEAT PUMPS - TESTING AND CALCULATING METHODS FOR SEASONAL PERFORMANCE FACTORS - PART 1: COOLING SEASONAL PERFORMANCE FACTOR
    12/30234068 DC : 0 BS ISO 16358-2 - AIR-COOLED AIR CONDITIONERS AND AIR-TO-AIR HEAT PUMPS - TESTING AND CALCULATING METHODS FOR SEASONAL PERFORMANCE FACTORS - PART 2: HEATING SEASONAL PERFORMANCE FACTOR
    ISO 16358-2:2013 Air-cooled air conditioners and air-to-air heat pumps Testing and calculating methods for seasonal performance factors Part 2: Heating seasonal performance factor
    BS ISO 16358-3:2013 AIR-COOLED AIR CONDITIONERS AND AIR-TO-AIR HEAT PUMPS - TESTING AND CALCULATING METHODS FOR SEASONAL PERFORMANCE FACTORS - PART 3: ANNUAL PERFORMANCE FACTOR
    BS ISO 16358-2:2013 AIR-COOLED AIR CONDITIONERS AND AIR-TO-AIR HEAT PUMPS - TESTING AND CALCULATING METHODS FOR SEASONAL PERFORMANCE FACTORS - PART 2: HEATING SEASONAL PERFORMANCE FACTOR
    BS ISO 5151:2017 Non-ducted air conditioners and heat pumps. Testing and rating for performance
    CSA C13256.1 : 2001 : R2016 WATER-SOURCE HEAT PUMPS - TESTING AND RATING FOR PERFORMANCE - PART 1: WATER-TO-AIR AND BRINE-TO-AIR HEAT PUMPS
    ISO 16358-1:2013 Air-cooled air conditioners and air-to-air heat pumps — Testing and calculating methods for seasonal performance factors — Part 1: Cooling seasonal performance factor
    IEC 60335-2-40 REDLINE : 6.0 HOUSEHOLD AND SIMILAR ELECTRICAL APPLIANCES - SAFETY - PART 2-40: PARTICULAR REQUIREMENTS FOR ELECTRICAL HEAT PUMPS, AIR-CONDITIONERS AND DEHUMIDIFIERS
    ISO 13261-1:1998 Sound power rating of air-conditioning and air-source heat pump equipment Part 1: Non-ducted outdoor equipment
    16/30300176 DC : 0 BS ISO 19659-1 - RAILWAY APPLICATIONS - HEATING, VENTILATION AND AIR CONDITIONING SYSTEMS FOR ROLLING STOCK - PART 1: TERMS AND DEFINITIONS
    UNI ISO 13380 : 2010 CONDITION MONITORING AND DIAGNOSTICS OF MACHINES - GENERAL GUIDELINES ON USING PERFORMANCE PARAMETERS
    CSA C13256.1:2001 WATER-SOURCE HEAT PUMPS - TESTING AND RATING FOR PERFORMANCE - PART 1: WATER-TO-AIR AND BRINE-TO-AIR HEAT PUMPS
    00/702358 DC : DRAFT JAN 2000 ISO/DIS 13380 - CONDITION MONITORING AND DIAGNOSTICS OF MACHINES - USE OF PERFORMANCE PARAMETERS - GENERAL GUIDELINES
    CSA PLUS 14021 : 2008 ENVIRONMENTAL CLAIMS: A GUIDE FOR INDUSTRY AND ADVERTISERS
    S.R. CEN ISO/TS 16491:2012 GUIDELINES FOR THE EVALUATION OF UNCERTAINTY OF MEASUREMENT IN AIR CONDITIONER AND HEAT PUMP COOLING AND HEATING CAPACITY TESTS (ISO/TS 16491:2012)
    EN ISO 14021:2016 Environmental labels and declarations - Self-declared environmental claims (Type II environmental labelling) (ISO 14021:2016)
    UNE-EN ISO 14021:2017 Environmental labels and declarations - Self-declared environmental claims (Type II environmental labelling) (ISO 14021:2016)
    ASHRAE HDBK REFRIGERATION : 2014 ASHRAE HANDBOOK - REFRIGERATION
    BS ISO 15042:2017 Multiple split-system air conditioners and air-to-air heat pumps. Testing and rating for performance
    BS ISO 16358-1:2013 Air-cooled air conditioners and air-to-air heat pumps. Testing and calculating methods for seasonal performance factors Cooling seasonal performance factor
    ISO 5151:2017 Non-ducted air conditioners and heat pumps — Testing and rating for performance
    CSA C13256.2 : 2001 : R2015 WATER-SOURCE HEAT PUMPS - TESTING AND RATING FOR PERFORMANCE - PART 2: WATER-TO-WATER AND BRINE-TO-WATER HEAT PUMPS
    CSA C13256.2 : 2001 WATER-SOURCE HEAT PUMPS - TESTING AND RATING FOR PERFORMANCE - PART 2: WATER-TO-WATER AND BRINE-TO-WATER HEAT PUMPS
    I.S. EN ISO 14021:2016 ENVIRONMENTAL LABELS AND DECLARATIONS - SELF-DECLARED ENVIRONMENTAL CLAIMS (TYPE 2 ENVIRONMENTAL LABELLING) (ISO 14021:2016)
    ISO 14021:2016 Environmental labels and declarations Self-declared environmental claims (Type II environmental labelling)
    ISO/TS 16491:2012 Guidelines for the evaluation of uncertainty of measurement in air conditioner and heat pump cooling and heating capacity tests
    BS EN ISO 14021:2016 Environmental labels and declarations. Self-declared environmental claims (Type II environmental labelling)
    ANSI/AHRI/ASHRAE ISO 13256-2 : 1998 WATER-SOURCE HEAT PUMPS - TESTING AND RATING FOR PERFORMANCE - PART 2: WATER-TO-WATER AND BRINE-TO-WATER HEAT PUMPS
    15/30284304 DC : 0 BS ISO 15042 - MULTIPLE SPLIT-SYSTEM AIR-CONDITIONERS AND AIR-TO-AIR HEAT PUMPS - TESTING AND RATING FOR PERFORMANCE
    ANSI/AHRI/ASHRAE ISO 13256-1 : 1998 : R2012 WATER-SOURCE HEAT PUMPS - TESTING AND RATING FOR PERFORMANCE - PART 1: WATER-TO-AIR AND BRINE-TO-AIR HEAT PUMPS
    CSA C13256.2 : 2001 : R2005 WATER-SOURCE HEAT PUMPS - TESTING AND RATING FOR PERFORMANCE - PART 2: WATER-TO-WATER AND BRINE-TO-WATER HEAT PUMPS
    ANSI/AHRI/ASHRAE ISO 13256-1:1998 WATER-SOURCE HEAT PUMPS - TESTING AND RATING FOR PERFORMANCE - PART 1: WATER-TO-AIR AND BRINE-TO-AIR HEAT PUMPS
    ISO 13380:2002 Condition monitoring and diagnostics of machines General guidelines on using performance parameters

    Standards Referencing This Book - (Show below) - (Hide below)

    ISO 5151:2017 Non-ducted air conditioners and heat pumps — Testing and rating for performance
    ISO 5167-1:2003 Measurement of fluid flow by means of pressure differential devices inserted in circular cross-section conduits running full Part 1: General principles and requirements
    ISO 15042:2017 Multiple split-system air conditioners and air-to-air heat pumps — Testing and rating for performance
    ISO 817:2014 Refrigerants Designation and safety classification
    ISO 3966:2008 Measurement of fluid flow in closed conduits Velocity area method using Pitot static tubes
    ISO/TS 16491:2012 Guidelines for the evaluation of uncertainty of measurement in air conditioner and heat pump cooling and heating capacity tests
    ISO/IEC Guide 98-3:2008 Uncertainty of measurement — Part 3: Guide to the expression of uncertainty in measurement (GUM:1995)
    • Access your standards online with a subscription

      Features

      • Simple online access to standards, technical information and regulations
      • Critical updates of standards and customisable alerts and notifications
      • Multi - user online standards collection: secure, flexibile and cost effective