ISO/IEC 14763-3:2014
Current
The latest, up-to-date edition.
Hardcopy , PDF , PDF 3 Users , PDF 5 Users , PDF 9 Users
07-08-2014
ISO/IEC 14763-3:2014(E) specifies systems and methods for the inspection and testing of installed optical fibre cabling designed in accordance with premises cabling standards including ISO/IEC 11801, ISO/IEC 24764, ISO/IEC 24702 and ISO/IEC 15018. The test methods refer to existing standards-based procedures where they exist. This second edition cancels and replaces the first edition published in 2006 and its Amendment 1:2009. It constitutes a technical revision. This edition includes the following changes:- general requirements have been revised; - OTDR characterization (6.2) and requirements for cabling interface adapters and test cords have been revised; - enhanced three-test-cord reference method has been introduced; - information on optical time domain reflectometry (Annex C) has been revised; - examples of calculations of channel and permanent link limits (Annex G) have been revised and information regarding cleaning and inspection of fibre optic connections have been added (Annex H).
DevelopmentNote |
Supersedes ISO/IEC TR 14763-3. (06/2006)
|
DocumentType |
Standard
|
Pages |
51
|
PublisherName |
International Organization for Standardization
|
Status |
Current
|
Supersedes |
Standards | Relationship |
CSA ISO/IEC 14763-3 : 2015 | Identical |
DIN ISO/IEC 14763-3 : 2014 | Identical |
VDE 0800-763-3 : 2014 | Identical |
NEN ISO/IEC 14763-3 : 2014 C1 2015 | Identical |
CAN/CSA-ISO/IEC 14763-3:15 (R2020) | Identical |
JIS X 5151:2018 | Identical |
BS ISO/IEC 14763-3 : 2006 | Identical |
PN ISO/IEC 14763-3 : 2009 AMD 1 2010 | Identical |
CSA ISO/IEC 14763-3A : 2010(R2012) | Identical |
12/30268386 DC : 0 | BS EN 50700 - INFORMATION TECHNOLOGY - PREMISES DISTRIBUTION ACCESS NETWORK (PDAN) CABLING TO SUPPORT DEPLOYMENT OF OPTICAL BROADBAND NETWORKS |
BS ISO/IEC 11801-1:2017 | Information technology. Generic cabling for customer premises General requirements |
PREN 50700 : DRAFT 2012 | INFORMATION TECHNOLOGY - PREMISES DISTRIBUTION ACCESS NETWORK (PDAN) CABLING TO SUPPORT DEPLOYMENT OF OPTICAL BROADBAND NETWORKS |
16/30325966 DC : 0 | BS ISO/IEC 11801-6 - INFORMATION TECHNOLOGY - GENERIC CABLING FOR CUSTOMER PREMISES - PART 6: DISTRIBUTED BUILDING SERVICES |
09/30211785 DC : 0 | BS ISO/IEC 14763-2 - INFORMATION TECHNOLOGY - IMPLEMENTATION AND OPERATION OF CUSTOMER PREMISES CABLING - PART 2: PLANNING AND INSTALLATION |
BS EN 61280-4-1:2009 | Fibre optic communication subsystem test procedures Installed cable plant. Multimode attenuation measurement |
BS ISO/IEC 11801-5:2017 | Information technology. Generic cabling for customer premises Data centres |
CSA ISO/IEC 14543-3-7 : 2007 : R2012 | INFORMATION TECHNOLOGY - HOME ELECTRONIC SYSTEM (HES) ARCHITECTURE - PART 3-7: MEDIA AND MEDIA DEPENDENT LAYERS - RADIO FREQUENCY FOR NETWORK BASED CONTROL OF HES CLASS 1 |
ISO/IEC 11801-2:2017 | Information technology Generic cabling for customer premises Part 2: Office premises |
CSA ISO/IEC 14543-3-5 : 2008 : R2013 | INFORMATION TECHNOLOGY - HOME ELECTRONIC SYSTEM (HES) ARCHITECTURE - PART 3-5: MEDIA AND MEDIA DEPENDENT LAYERS - POWERLINE FOR NETWORK BASED CONTROL OF HES CLASS 1 |
I.S. EN 61280-4-2:2014 | FIBRE-OPTIC COMMUNICATION SUBSYSTEM TEST PROCEDURES - PART 4-2: INSTALLED CABLE PLANT - SINGLE-MODE ATTENUATION AND OPTICAL RETURN LOSS MEASUREMENT |
PD IEC/TR 61282-14:2016 | Fibre optic communication system design guides Determination of the uncertainties of attenuation measurements in fibre plants |
ISO/IEC 11801-4:2017 | Information technology Generic cabling for customer premises Part 4: Single-tenant homes |
ISO/IEC 14763-2:2012 | Information technology Implementation and operation of customer premises cabling Part 2: Planning and installation |
I.S. EN 50346:2003 | INFORMATION TECHNOLOGY - CABLING INSTALLATION - TESTING OF INSTALLED CABLING |
ISO/IEC 24702:2006 | Information technology Generic cabling Industrial premises |
ISO/IEC 14543-3-4:2007 | Information technology Home electronic system (HES) architecture Part 3-4: System management Management procedures for network based control of HES Class 1 |
ISO/IEC 14543-3-6:2007 | Information technology Home electronic system (HES) architecture Part 3-6: Media and media dependent layers Network based on HES Class 1, twisted pair |
EN 61280-4-2:2014 | Fibre-optic communication subsystem test procedures - Part 4-2: Installed cable plant - Single-mode attenuation and optical return loss measurement |
EN 61280-4-1:2009 | FIBRE OPTIC COMMUNICATION SUBSYSTEM TEST PROCEDURES - PART 4-1: INSTALLED CABLE PLANT - MULTIMODE ATTENUATION MEASUREMENT |
EN 50700:2014 | Information technology - Premises distribution access network (PDAN) cabling to support deployment of optical broadband networks |
EN 50346 : 2002 AMD 2 2009 | INFORMATION TECHNOLOGY - CABLING INSTALLATION - TESTING OF INSTALLED CABLING |
BS EN 61280-4-2:2014 | Fibre-optic communication subsystem test procedures Installed cable plant. Single-mode attenuation and optical return loss measurement |
16/30325955 DC : 0 | BS ISO/IEC 11801-5 - INFORMATION TECHNOLOGY - GENERIC CABLING FOR CUSTOMER PREMISES - PART 5: DATA CENTRES |
BS EN 50346 : 2002 | INFORMATION TECHNOLOGY - CABLING INSTALLATION - TESTING OF INSTALLED CABLING |
CAN/CSA-ISO/IEC 14543-3-3-07 (R2017) | Information Technology - Home Electronic System (HES) Architecture - Part 3-3: User Process for Network Based Control of HES Class 1 (Adopted ISO/IEC 14543-3-3:2007, first edition, 2007-01) |
CSA ISO /IEC 14543-3-4 : 2007 | INFORMATION TECHNOLOGY - HOME ELECTRONIC SYSTEM (HES) ARCHITECTURE - PART 3-4: SYSTEM MANAGEMENT - MANAGEMENT PROCEDURES FOR NETWORK BASED CONTROL OF HES CLASS 1 |
ISO/IEC 11801-1:2017 | Information technology — Generic cabling for customer premises — Part 1: General requirements |
CSA ISO/IEC 14543-3-4 : 2007 : R2012 | INFORMATION TECHNOLOGY - HOME ELECTRONIC SYSTEM (HES) ARCHITECTURE - PART 3-4: SYSTEM MANAGEMENT - MANAGEMENT PROCEDURES FOR NETWORK BASED CONTROL OF HES CLASS 1 |
IEC TR 61282-11:2012 | Fibre optic communication system design guides - Part 11: Multimode launch conditions |
BS PD ISO/IEC TR 29106 : 2007 | INFORMATION TECHNOLOGY - GENERIC CABLING - INTRODUCTION TO THE MICE ENVIRONMENTAL CLASSIFICATION |
BS EN 50174-1 : 2009 | INFORMATION TECHNOLOGY - CABLING INSTALLATION - PART 1: INSTALLATION SPECIFICATION AND QUALITY ASSURANCE |
IEC TR 62614-2:2015 | Fibre optics - Multimode launch conditions - Part 2: Determination of launch condition requirements for measuring multimode attenuation |
IEC 61280-4-1:2009 | Fibre-optic communication subsystem test procedures - Part 4-1: Installed cable plant - Multimode attenuation measurement |
I.S. EN 61918:2013 | INDUSTRIAL COMMUNICATION NETWORKS - INSTALLATION OF COMMUNICATION NETWORKS IN INDUSTRIAL PREMISES |
16/30325974 DC : 0 | BS ISO/IEC 11801-2 - INFORMATION TECHNOLOGY - GENERIC CABLING FOR CUSTOMER PREMISES - PART 2: OFFICE PREMISES |
16/30325952 DC : 0 | BS ISO/IEC 11801-4 - INFORMATION TECHNOLOGY - GENERIC CABLING FOR CUSTOMER PREMISES - PART 4: HOMES |
BS ISO/IEC 11801-2:2017 | Information technology. Generic cabling for customer premises Office premises |
CEI EN 61280-4-1 : 2011 | FIBRE OPTIC COMMUNICATION SUBSYSTEM TEST PROCEDURES - PART 4-1: INSTALLED CABLE PLANT - MULTIMODE ATTENUATION MEASUREMENT |
BS IEC/IEEE 62582-5:2015 | Nuclear power plants. Instrumentation and control important to safety. Electrical equipment condition monitoring methods Optical time domain reflectometry |
ISO/IEC 11801-6:2017 | Information technology Generic cabling for customer premises Part 6: Distributed building services |
CEI EN 61280-4-2 : 2015 | FIBRE-OPTIC COMMUNICATION SUBSYSTEM TEST PROCEDURES - PART 4-2: INSTALLED CABLE PLANT - SINGLE-MODE ATTENUATION AND OPTICAL RETURN LOSS MEASUREMENT |
ISO/IEC 14762:2009 | Information technology Functional safety requirements for Home and Building Electronic Systems (HBES) |
CSA ISO/IEC 14543-3-3 : 2007 | INFORMATION TECHNOLOGY - HOME ELECTRONIC SYSTEM (HES) ARCHITECTURE - PART 3-3: USER PROCESS FOR NETWORK BASED CONTROL OF HES CLASS 1 |
CSA ISO/IEC 14543-3-5 : 2008 | INFORMATION TECHNOLOGY - HOME ELECTRONIC SYSTEM (HES) ARCHITECTURE - PART 3-5: MEDIA AND MEDIA DEPENDENT LAYERS - POWERLINE FOR NETWORK BASED CONTROL OF HES CLASS 1 |
I.S. EN 50174-1:2009 | INFORMATION TECHNOLOGY - CABLING INSTALLATION - PART 1: INSTALLATION SPECIFICATION AND QUALITY ASSURANCE |
ISO/IEC 30129:2015 | Information technology Telecommunications bonding networks for buildings and other structures |
ISO/IEC 14543-3-7:2007 | Information technology Home electronic system (HES) architecture Part 3-7: Media and media dependent layers Radio frequency for network based control of HES Class 1 |
ISO/IEC 14543-3-5:2007 | Information technology Home electronic system (HES) architecture Part 3-5: Media and media dependent layers Power line for network based control of HES Class 1 |
IEC 61918:2013 | Industrial communication networks - Installation of communication networks in industrial premises |
BS EN 61918:2013 | Industrial communication networks. Installation of communication networks in industrial premises |
10/30240050 DC : DRAFT DEC 2010 | BS EN 61280-4-2 - FIBRE-OPTIC COMMUNICATION SUBSYSTEM TEST PROCEDURES - PART 4-2: INSTALLED CABLE PLANT - SINGLEMODE ATTENUATION AND OPTICAL RETURN LOSS MEASUREMENT |
11/30244353 DC : 0 | BS EN 61753-123-2 - FIBRE OPTIC INTERCONNECTING DEVICES AND PASSIVE COMPONENTS - PERFORMANCE STANDARD - PART 123-2: SIMPLEX AND DUPLEX REFERENCE CORDS WITH SINGLE-MODE FIBRE AND CYLINDRICAL FERRULE CONNECTORS |
PD IEC/TR 61282-11:2012 | Fibre optic communication system design guides Multimode launch conditions |
15/30326655 DC : 0 | BS EN 61280-4-1 - FIBRE-OPTIC COMMUNICATION SUBSYSTEM TEST PROCEDURES - PART 4-1: INSTALLED CABLE PLANT - MULTIMODE ATTENUATION MEASUREMENT |
09/30211750 DC : 0 | BS EN 50174-1:200/PRA1:2 - INFORMATION TECHNOLOGY - CABLING INSTALLATION - PART 1: INSTALLATION SPECIFICATION AND QUALITY ASSURANCE |
BS EN 50700:2014 | Information technology. Premises distribution access network (PDAN) cabling to support deployment of optical broadband networks |
16/30325949 DC : 0 | BS ISO/IEC 11801-3 - INFORMATION TECHNOLOGY - GENERIC CABLING FOR CUSTOMER PREMISES - PART 3: INDUSTRIAL PREMISES |
16/30325971 DC : 0 | BS ISO/IEC 11801-1 - INFORMATION TECHNOLOGY - GENERIC CABLING FOR CUSTOMER PREMISES - PART 1: GENERAL REQUIREMENTS |
ISO/IEC 11801-5:2017 | Information technology Generic cabling for customer premises Part 5: Data centres |
CAN/CSA-ISO/IEC 14543-3-7-07 (R2017) | Information Technology - Home Electronic System (HES) Architecture - Part 3-7: Media and Media Dependent Layers - Radio Frequency for Network Based Control of HES Class 1 (Adopted ISO/IEC 14543-3-7:2007, first edition, 2007-01) |
UFC 3-580-01 : Change 1 | UNIFIED FACILITIES CRITERIA - TELECOMMUNICATIONS INTERIOR INFRASTRUCTURE PLANNING AND DESIGN |
CSA ISO/IEC 14543-3-3 : 2007 : R2012 | INFORMATION TECHNOLOGY - HOME ELECTRONIC SYSTEM (HES) ARCHITECTURE - PART 3-3: USER PROCESS FOR NETWORK BASED CONTROL OF HES CLASS 1 |
CSA ISO/IEC 14543-3-6 : 2007 : R2012 | INFORMATION TECHNOLOGY - HOME ELECTRONIC SYSTEM (HES) ARCHITECTURE - PART 3-6: MEDIA AND MEDIA DEPENDENT LAYERS - TWISTED PAIR FOR NETWORK BASED CONTROL OF HES CLASS 1 |
IEEE 802.3-2012 | IEEE Standard for Ethernet |
ISO/IEC 14543-3-3:2007 | Information technology Home electronic system (HES) architecture Part 3-3: User process for network based control of HES Class 1 |
ISO/IEC TR 29106:2007 | Information technology Generic cabling Introduction to the MICE environmental classification |
EN 50174-1:2009/A2:2014 | INFORMATION TECHNOLOGY - CABLING INSTALLATION - PART 1: INSTALLATION SPECIFICATION AND QUALITY ASSURANCE |
IEC 61280-4-2:2014 | Fibre-optic communication subsystem test procedures - Part 4-2: Installed cable plant - Single-mode attenuation and optical return loss measurement |
BS ISO/IEC 30129 : 2015 | INFORMATION TECHNOLOGY - TELECOMMUNICATIONS BONDING NETWORKS FOR BUILDINGS AND OTHER STRUCTURES |
CSA ISO/IEC 14762 : 2010 | INFORMATION TECHNOLOGY - FUNCTIONAL SAFETY REQUIREMENTS FOR HOME AND BUILDING ELECTRONIC SYSTEMS (HBES) |
11/30247511 DC : 0 | BS EN 61753-124-2 - FIBRE OPTIC INTERCONNECTING DEVICES AND PASSIVE COMPONENTS - PART 124-2: SIMPLEX AND DUPLEX REFERENCE CORDS WITH MULTIMODE FIBRE AND CYLINDRICAL FERRULE CONNECTORS FOR CATEGORY C - CONTROLLED ENVIRONMENT |
14/30189466 DC : 0 | BS IEC/IEEE 62582-5 ED 1.0 - NUCLEAR POWER PLANTS - INSTRUMENTATION AND CONTROL IMPORTANT TO SAFETY - ELECTRICAL EQUIPMENT CONDITION MONITORING METHODS - PART 5: OPTICAL TIME DOMAIN REFLECTOMETRY |
CAN/CSA-ISO/IEC 14543-3-4-07 (R2017) | Information Technology - Home Electronic System (HES) Architecture - Part 3-4: System Management - Management Procedures for Network Based Control of HES Class 1 (Adopted ISO/IEC 14543-3-4:2007, first edition, 2007-01) |
CSA ISO/IEC 14543-3-6 : 2007 | INFORMATION TECHNOLOGY - HOME ELECTRONIC SYSTEM (HES) ARCHITECTURE - PART 3-6: MEDIA AND MEDIA DEPENDENT LAYERS - TWISTED PAIR FOR NETWORK BASED CONTROL OF HES CLASS 1 |
CAN/CSA-ISO/IEC 14543-3-6-07 (R2017) | Information Technology - Home Electronic System (HES) Architecture - Part 3-6: Media and Media Dependent Layers - Twisted Pair for Network Based Control of HES Class 1 (Adopted ISO/IEC 14543-3-6:2007, first edition, 2007-01) |
ISO/IEC 11801-3:2017 | Information technology Generic cabling for customer premises Part 3: Industrial premises |
I.S. EN 61280-4-1:2009 | FIBRE OPTIC COMMUNICATION SUBSYSTEM TEST PROCEDURES - PART 4-1: INSTALLED CABLE PLANT - MULTIMODE ATTENUATION MEASUREMENT |
I.S. EN 50700:2014 | INFORMATION TECHNOLOGY - PREMISES DISTRIBUTION ACCESS NETWORK (PDAN) CABLING TO SUPPORT DEPLOYMENT OF OPTICAL BROADBAND NETWORKS |
EN 61918:2013/AC:2014 | INDUSTRIAL COMMUNICATION NETWORKS - INSTALLATION OF COMMUNICATION NETWORKS IN INDUSTRIAL PREMISES (IEC 61918:2013, MODIFIED) |
11/30258071 DC : 0 | BS EN 61918 - INDUSTRIAL COMMUNICATION NETWORKS - INSTALLATION OF COMMUNICATION NETWORKS IN INDUSTRIAL PREMISES |
ISO/IEC 14763-2:2012 | Information technology Implementation and operation of customer premises cabling Part 2: Planning and installation |
IEC 60825-2:2004+AMD1:2006+AMD2:2010 CSV | Safety of laser products - Part 2: Safety of optical fibre communication systems (OFCS) |
ISO/IEC 15018:2004 | Information technology Generic cabling for homes |
IEC 60050-731:1991 | International Electrotechnical Vocabulary (IEV) - Part 731: Optical fibre communication |
IEC 61280-1-3:2010 | Fibre optic communication subsystem test procedures - Part 1-3: General communication subsystems - Central wavelength and spectral width measurement |
IEC 60793-2-10:2017 | Optical fibres - Part 2-10: Product specifications - Sectional specification for category A1 multimode fibres |
ISO/IEC 24702:2006 | Information technology Generic cabling Industrial premises |
AS 11801.6:2019 | Information technology - Generic cabling for customer premises Distributed building services (ISO/IEC 11801-6:2017, MOD) |
ISO/IEC 11801:2002 | Information technology Generic cabling for customer premises |
IEC 60793-2-40:2015 | Optical fibres - Part 2-40: Product specifications - Sectional specification for category A4 multimode fibres |
IEC 62664-1-1:2013 | Fibre optic interconnecting devices and passive components - Fibre optic connector product specifications - Part 1-1: LC-PC duplex multimode connectors terminated on IEC 60793-2-10 category A1a fibre |
IEC 61746-1:2009 | Calibration of optical time-domain reflectometers (OTDR) - Part 1: OTDR for single mode fibres |
IEC TR 62627-01:2016 | Fibre optic interconnecting devices and passive components - Part 01: Fibre optic connector cleaning methods |
IEC 60874-19-1:2007 | Fibre optic interconnecting devices and passive components - Connectors for optical fibres and cables - Part 19-1: Fibre optic patch cord connector type SC-PC (floating duplex) standard terminated on multimode fibre type A1a, A1b - Detail specification |
IEC 61935-3:2008 | Testing of balanced and coaxial information technology cabling - Part 3: Installed cabling as specified in ISO/IEC 15018 and related standards |
ISO/IEC 14763-1:1999 | Information technology Implementation and operation of customer premises cabling Part 1: Administration |
AS 11801.3:2019 | Information technology - Generic cabling for customer premises Industrial premises (ISO/IEC 11801-3:2017, MOD) |
IEC 60874-14-3:1997 | Connectors for optical fibres and cables - Part 14-3: Detail specification for fibre optic adaptor (simplex) type SC for single-mode fibre |
IEC 60874-1:2011 | Fibre optic interconnecting devices and passive components - Connectors for optical fibres and cables - Part 1: Generic specification |
IEC 61280-4-1:2009 | Fibre-optic communication subsystem test procedures - Part 4-1: Installed cable plant - Multimode attenuation measurement |
IEC 61280-4-2:2014 | Fibre-optic communication subsystem test procedures - Part 4-2: Installed cable plant - Single-mode attenuation and optical return loss measurement |
AS 11801.2:2019 | Information technology - Generic cabling for customer premises Office premises (ISO/IEC 11801-2:2017, MOD) |
IEC 61300-3-6:2008 | Fibre optic interconnecting devices and passive components - Basic test and measurement procedures - Part 3-6: Examinations and measurements - Return loss |
IEC 61300-3-35:2015 RLV | Fibre optic interconnecting devices and passive components - Basic test and measurement procedures - Part 3-35: Examinations and measurements - Visual inspection of fibre optic connectors and fibre-stub transceivers |
IEC 61300-3-4:2012 | Fibre optic interconnecting devices and passive components - Basic test and measurement procedures - Part 3-4: Examinations and measurements - Attenuation |
IEC 61935-1:2015 | Specification for the testing of balanced and coaxial information technology cabling - Part 1: Installed balanced cabling as specified in ISO/IEC 11801 and related standards |
IEC 61746-2:2010 | Calibration of optical time-domain reflectometers (OTDR) - Part 2: OTDR for multimode fibres |
IEC 60793-2-50:2015 | Optical fibres - Part 2-50: Product specifications - Sectional specification for class B single-mode fibres |
IEC 61755-3-2:2006 | Fibre optic connector optical interfaces - Part 3-2: Optical interface, 2,5 mm and 1,25 mm diameter cylindrical full zirconia ferrules for 8 degrees angled-PC single mode fibres |
IEC 61315:2005 | Calibration of fibre-optic power meters |
ISO/IEC 24764:2010 | Information technology Generic cabling systems for data centres |
IEC 62614:2010 | Fibre optics - Launch condition requirements for measuring multimode attenuation |
IEC 61755-3-1:2006 | Fibre optic connector optical interfaces - Part 3-1: Optical interface, 2,5 mm and 1,25 mm diameter cylindrical full zirconia PC ferrule, single mode fibre |
IEC 61300-3-42:2007 | Fibre optic interconnecting devices and passive components - Basic test and measurement procedures - Part 3-42: Examinations and measurements - Attenuation of single mode alignment sleeves and or adaptors with resilient alignment sleeves |
IEC 61280-1-4:2009 | Fibre optic communication subsystem test procedures - Part 1-4: General communication subsystems - Light source encircled flux measurement method |
IEC TR 61282-11:2012 | Fibre optic communication system design guides - Part 11: Multimode launch conditions |
IEC 61745:2017 | End-face image analysis procedure for the calibration of optical fibre geometry test sets |
Please Login or Create an Account so you can add users to your Multi user PDF Later.
Important note : All end users must be registered with an Account prior to user licenses being assigned.
Users cannot be edited or removed once added to your Multi user PDF.
Access your standards online with a subscription
Features
-
Simple online access to standards, technical information and regulations.
-
Critical updates of standards and customisable alerts and notifications.
-
Multi-user online standards collection: secure, flexible and cost effective.