• There are no items in your cart

NBN EN 50104 : 2010

Current
Current

The latest, up-to-date edition.

ELECTRICAL APPARATUS FOR THE DETECTION AND MEASUREMENT OF OXYGEN - PERFORMANCE REQUIREMENTS AND TEST METHODS
Published date

01-12-2013

1 Scope
2 Normative references
3 Definitions
  3.1 Gas properties
  3.2 Types of instruments
  3.3 Sensors
  3.4 Supply of gas to instrument
  3.5 Signals and alarms
  3.6 Times
4 General requirements
  4.1 Introduction
  4.2 Construction
      4.2.1 General
      4.2.2 Indicating devices
      4.2.3 Alarm or output functions
      4.2.4 Fault signal
      4.2.5 Adjustments
      4.2.6 Battery-powered apparatus
      4.2.7 Software-controlled apparatus
5 Test methods
  5.1 Introduction
  5.2 General requirements for tests
      5.2.1 Samples and sequence of tests
      5.2.2 Preparation of apparatus before testing
      5.2.3 Mask for calibration and test
  5.3 Normal conditions for test
      5.3.1 General
      5.3.2 Test gas(es)
      5.3.3 Flow rate for test gases
      5.3.4 Voltage
      5.3.5 Ambient temperature
      5.3.6 Pressure
      5.3.7 Humidity
      5.3.8 Stabilisation time
      5.3.9 Orientation
  5.4 Test methods and performance requirements
      5.4.1 General
      5.4.2 Unpowered storage of the apparatus
      5.4.3 Calibration, adjustment and repeatability
      5.4.4 Drift (continuous duty apparatus only)
      5.4.5 Stability (spot-reading apparatus only)
      5.4.6 Alarm set point(s)
      5.4.7 Temperature
      5.4.8 Pressure
      5.4.9 Humidity
      5.4.10 Air velocity
      5.4.11 Flow rate
      5.4.12 Orientation
      5.4.13 Vibration
      5.4.14 Drop test
      5.4.15 Warm-up time (not applicable to spot-reading
             apparatus)
      5.4.16 Time of response
      5.4.17 Minimum time to operate (spot-reading
             apparatus)
      5.4.18 Battery capacity
      5.4.19 Power supply variations
      5.4.20 Electromagnetic compatibility
      5.4.21 Addition of sampling probe
      5.4.22 Dust (for apparatus where the atmosphere is
             sampled by diffusion only)
      5.4.23 Poisons and other gases
      5.4.24 Field verification kit
6 Information for use
  6.1 Labelling and marking
  6.2 Instruction manual
Annex A (informative) Sequence of tests
Annex B (informative) Bibliography

Gives test methods and performance requirements for portable, transportable and fixed electrical apparatus for the measurement of oxygen concentration in gas mixtures indicating up to 25 % (V/V).

DocumentType
Standard
PublisherName
Belgian Standards
Status
Current

Standards Relationship
EN 50104:2010 Identical
NF EN 50104 : 2010 Identical
SN EN 50104 : 2010 Identical
DIN EN 50104 : 2011 Identical
I.S. EN 50104:2010 Identical
BS EN 50104:2010 Identical
NEN EN 50104 : 2010 Identical
UNE-EN 50104:2011 Identical

View more information
Sorry this product is not available in your region.

Access your standards online with a subscription

Features

  • Simple online access to standards, technical information and regulations.

  • Critical updates of standards and customisable alerts and notifications.

  • Multi-user online standards collection: secure, flexible and cost effective.