WC 8:1988
Superseded
A superseded Standard is one, which is fully replaced by another Standard, which is a new edition of the same Standard.
A superseded Standard is one, which is fully replaced by another Standard, which is a new edition of the same Standard.
01-30-2001
01-12-2013
PART 1 - GENERAL
Scope
General Information
Information to be Supplied by Purchaser
PART 2 - CONDUCTORS
Wires, Physical, and Electrical Properties
Solid Conductors
Stranded Conductors
Conductor Size Units
Conductor DC Resistance per Unit Length
Conductor Diameter
Stress Control Layer (Conductor Shield)
PART 3 - INSULATION
Material
Insulation Thickness
Insulation Thickness for Submarine Power Cable
Repairs
Insulation Types and Requirements
Type I Insulation
Type II Insulation
PART 4 - SHIELDING AND COVERINGS
Shielding of Insulated Cables
Shielding Limits for Power Cable for Fixed Locations
Jackets
General
Rubber or Thermoplastic Jackets
Metallic and Associated Coverings
Metallic and Associated Coverings
Division I - Coverings for Use Under Normal Conditions
Division II - Round Wire Armor for Borehole, Dredge,
Shaft, and Vertical Riser Cable
Division III - Round Wire Armor for Buried Cable
PART 5 - ASSEMBLY, FILLERS, AND CONDUCTOR IDENTIFICATION
Assembly of Multiple-conductor Cables
Fillers
Conductor Identification
PART 6 - TESTING AND TEST METHODS
Testing
Selection of Samples
Conductor Test Methods
Thickness Measurements for Insulations and Nonmetallic
Jackets
Physical and Aging Tests for Insulations, Jackets, and
Nonmetallic Conducting Materials
Tensile Strength Test
Tensile Stress Test
Elongation Test
Set Test
Aging Tests
Physical Tests for Nonmetallic Conducting Materials
Intended for Extrusion
Tear Test
Thickness of Jute Beddings and Servings
Thickness of Metallic Tapes
Thickness of Metallic Sheaths
Heat Shock
Heat Distortion
Cold Bend
Environmental Cracking
Absorption Coefficient
Accelerated Water Absorption
Capacity and Power Factor
Tests for Discharge Resistance
Volume Resistivity
Stripping Test
Retests for Tests Covered by 6.13 through 6.25 and
6.30 and 6.31
Electrical Tests on Completed Cables
Voltage Tests
Insulation Resistance
Partial-discharge Test Procedure
Method for Flexibility Test for Continuously Corrugated
Armor
Method for Determining Permittivity (S.I.C.) and
Dielectric Strength of Extruded Nonconducting
Polymeric Stress Control Layers
Hot Creep Test
PART 7 - CONSTRUCTIONS OF SPECIFIC TYPES
Mine Power Cables
Portable Single- and Multiple-conductor Power Cables
General Description of Completed Cables
Preassembled Aerial Cables
Single- and Multiple-conductor Flexible Cords
Control Cables
Optional Flame Test Requirements (Deleted)
Concentric-neutral Underground Distribution Cables
Concentric-neutral Underground Distribution Cables
Metal-clad Cables with Grounding Conductor
Nonshielded Single-conductor Power Cable
Nonshielded Single-conductor Cables for Series-lighting
Circuits
PART 8 - APPENDICES
A. Abbreviations and Symbols
B. Representative Tensile Strength and Elongation of
Nonmagentic Metals
C. Definitions for Maximum Temperature of Conductors
in Insulated Wire and Cable
Maximum Conductor Temperature - Operating
Maximum Conductor Temperature - Emergency Overload
Maximum Conductor Temperature - Short Circuit
D. Emergency Overloads
E. ICEA Publications and ASTM Standards
ICEA Publications
ASTM Standards
F. Ampacities for Two-conductor Concentric-neutral
Single-phase Primary Underground Residential
Distribution Cables
F.1 Ampacities for Three-phase Underground Distribution
Cables
G. Shielding
Definition of Shielding
Functions of Shielding
Use of Insulation Shielding
Grounding of the Insulation Shield
Shield Materials
Splices and Terminations
H. Recommended Bending Radii for Cables
Scope
Power Cables without Metallic Shielding or Armor
Power Cables with Metallic Shielding or Armor
Portable Cables
Drum Diameters of Reels
I. Ampacities for Three-conductor Mine Power Cables
J. Ampacities and Voltage Ratings of Portable Cables
K. Deleted
L. Additional Conductor Information
M. Ampacities for Preassembled Aerial Cables
N. Flexible Cords and Remote Control and Drill Cords
Access your standards online with a subscription
Features
-
Simple online access to standards, technical information and regulations.
-
Critical updates of standards and customisable alerts and notifications.
-
Multi-user online standards collection: secure, flexible and cost effective.