NFPA 72H : 1988

Withdrawn
Withdrawn

A Withdrawn Standard is one, which is removed from sale, and its unique number can no longer be used. The Standard can be withdrawn and not replaced, or it can be withdrawn and replaced by a Standard with a different number.

View Superseded by
withdrawn

A Withdrawn Standard is one, which is removed from sale, and its unique number can no longer be used. The Standard can be withdrawn and not replaced, or it can be withdrawn and replaced by a Standard with a different number.

TESTING PROCEDURES FOR LOCAL, AUXILIARY, REMOTE STATION, AND PROPRIETARY PROTECTIVE SIGNALING SYSTEMS
Withdrawn date

04-14-2021

Published date

01-12-2013

Chapter 1 General
1.1 Scope
1.2 Definitions
1.3 Fire Alarm System Certification and Description
      Document
Chapter 2 Acceptance and Reacceptance Testing Procedures
2.1 General
2.2 Installation Testing
2.3 System Testing
2.4 Reacceptance Testing
Chapter 3 Periodic Equipment and Circuit Testing
           Procedures
3.1 Periodic Testing
Chapter 4 Recommended Schedules and Methods for Testing
           Procedures
4.1 General
Chapter 5 Procedure for Testing Systems Equipped with
           Alarm Verification
Chapter 6 Multiplex System Testing Procedures
Chapter 7 Typical Circuit Wiring Diagrams
7.1
7.2 Diagram of Nonpowered Alarm or Supervisory
      Initiating Devices (e.g. Manual Station or Valve
      Supervisory Switch) Connected to Style A, B, or C
      Initiating Device Circuits
7.3 Diagram of Nonpowered Alarm or Supervisory
      Initiating Devices Connected to Style D or E
      Initiating Device Circuits
7.4 Diagram of Circuit-Powered (2-Wire) Smoke Detectors
      for Style A, B, or C Initiating Device Circuits
7.5 Diagram of Circuit-Powered (2-Wire) Smoke Detectors
      for Style D or E Initiating Device Circuits
7.6 Diagram of Combination Alarm Initiating Device and
      Indicating Appliance Circuits
7.7 Diagram of Combination Alarm Initiating Device and
      Indicating Circuits Arranged for Operation with a
      Single Open or Ground Fault
7.8 Diagram of Style A, B, or C Circuits with 4-Wire
      Smoke Detectors and an End-of-Line Power Supervision
      Relay
7.9 Diagram of Style A, B, or C Initiating Device
      Circuits with 4-Wire Smoke Detectors that Include
      Integral Individual Supervision Relays
7.10 Diagrams of Alarm Indicating Appliances
7.11 Diagram of System with a Supervised Audible
      Indicating Appliance Circuit and an Unsupervised
      Visible Indicating Appliance Circuit
7.12 Diagram of System with Supervised Audible and
      Visible Indicating Appliance Circuits
7.13 Diagram of Series Indicating Appliance Circuit,
      which No Longer Meets the Requirements of NFPA 72A,
      NFPA 72D, and NFPA 72F
7.14 Diagram of Supervised Series Supervisory Initiating
      Circuit with Sprinkler Supervisory Valve Switches
      Connected, which No Longer Meets the Requirements
      of NFPA 72A, NFPA 72D, and NFPA 72F
7.15 Diagram of Initiating Device Circuit with Parallel
      Waterflow Alarm Switches and a Series Supervisory
      Valve Switch, which No Longer Meets the Requirements
      of NFPA 72A, NFPA 72D, or NFPA 72F
7.16 Diagram of an Auxiliary Circuit Connected to a
      Municipal Fire Alarm Master Box
7.17 Diagram of Door Hold and Release Unit with
      Unsupervised Wiring
7.18 Diagram of Remote Relays Connected to an
      Unsupervised Indicating Appliance Circuit
Chapter 8 Referenced Publications
Index

Provides procedures for acceptance and periodic testing of installed protective signaling systems.

DocumentType
Standard
PublisherName
National Fire Protection Association
Status
Withdrawn
SupersededBy

NFPA 72G : 1989 INSTALLATION, MAINTENANCE, AND USE OF NOTIFICATION APPLIANCES FOR PROTECTIVE SIGNALING SYSTEMS
NFPA 72B : 1986 INSTALLATION, MAINTENANCE, AND USE OF AUXILIARY PROTECTIVE SIGNALING SYSTEMS
NFPA 72F : 1985 INSTALLATION, MAINTENANCE, AND USE OF EMERGENCY VOICE/ALARM COMMUNICATION SYSTEMS
NFPA 72A : 1987 INSTALLATION, MAINTENANCE, AND USE OF LOCAL PROTECTIVE SIGNALING SYSTEMS
NFPA 72C : 1986 INSTALLATION, MAINTENANCE, AND USE OF REMOTE STATION PROTECTIVE SIGNALING SYSTEMS
NFPA 19911 : 1991 FIRE PROTECTION OF MUSEUMS AND MUSEUM COLLECTIONS
NFPA 12B : 1990 HALON 1211 FIRE EXTINGUISHING SYSTEMS
IEEE 241 : 1990 ELECTRIC POWER SYSTEMS IN COMMERCIAL BUILDINGS
NFPA 72D : 1986 INSTALLATION, MAINTENANCE, AND USE OF PROPRIETARY PROTECTIVE SIGNALING SYSTEMS
NFPA 913 : 1992 HISTORIC SITES AND STRUCTURES

NFPA 22 : 2013 WATER TANKS FOR PRIVATE FIRE PROTECTION
NFPA 72B : 1986 INSTALLATION, MAINTENANCE, AND USE OF AUXILIARY PROTECTIVE SIGNALING SYSTEMS
NFPA 172 : 1986 STANDARD FIRE PROTECTION SYMBOLS FOR ARCHITECTURAL AND ENGINEERING DRAWINGS
NFPA 110 : 2016 EMERGENCY AND STANDBY POWER SYSTEMS
NFPA 17 : 2017 DRY CHEMICAL EXTINGUISHING SYSTEMS
NFPA 72E : 1990 AUTOMATIC FIRE DETECTORS
NFPA 13A : 1987 INSPECTION, TESTING, AND MAINTENANCE OF SPRINKLER SYSTEMS
NFPA 26 : 1988 SUPERVISION OF VALVES CONTROLLING WATER SUPPLIES
NFPA 12 : 2015 CARBON DIOXIDE EXTINGUISHING SYSTEMS
NFPA 72A : 1987 INSTALLATION, MAINTENANCE, AND USE OF LOCAL PROTECTIVE SIGNALING SYSTEMS
NFPA 72D : 1986 INSTALLATION, MAINTENANCE, AND USE OF PROPRIETARY PROTECTIVE SIGNALING SYSTEMS
NFPA 72C : 1986 INSTALLATION, MAINTENANCE, AND USE OF REMOTE STATION PROTECTIVE SIGNALING SYSTEMS
NFPA 12A : 2015 HALON 1301 FIRE EXTINGUISHING SYSTEMS
NFPA 13D : 2016 INSTALLATION OF SPRINKLER SYSTEMS IN ONE- AND TWO-FAMILY DWELLINGS AND MANUFACTURED HOMES
NFPA 72F : 1985 INSTALLATION, MAINTENANCE, AND USE OF EMERGENCY VOICE/ALARM COMMUNICATION SYSTEMS
NFPA 20 : 2016 INSTALLATION OF STATIONARY PUMPS FOR FIRE PROTECTION

View more information
Sorry this product is not available in your region.

Access your standards online with a subscription

Features

  • Simple online access to standards, technical information and regulations.

  • Critical updates of standards and customisable alerts and notifications.

  • Multi-user online standards collection: secure, flexible and cost effective.