HOT APPLIED JOINT SEALANTS - PART 13: TEST METHOD FOR THE DETERMINATION OF THE DISCONTINUOUS EXTENSION (ADHERENCE TEST)

Published date

01-12-2013

Foreword
1 Scope
2 Normative references
3 Terms and definitions
4 Principle
5 Apparatus
   5.1 Tensile test rig
   5.2 Cooling chamber
6 Preparation and conditioning of test specimens
7 Storage of test specimens
   7.1 Air conditioned test specimens
   7.2 Water immersed test specimens
8 Procedure
9 Calculation and expression of results
   9.1 Tensions
   9.2 Failures
10 Precision
11 Test report

Describes a method for determining the cohesive extensibility and the adhesion to concrete of hot applied sealant-systems with or without priming simulating the moving of concrete pavement slabs during cooling conditions in wintertime.