• There are no items in your cart

UNI EN 12873-2 : 2005

Withdrawn

Withdrawn

A Withdrawn Standard is one, which is removed from sale, and its unique number can no longer be used. The Standard can be withdrawn and not replaced, or it can be withdrawn and replaced by a Standard with a different number.

View Superseded by
withdrawn

A Withdrawn Standard is one, which is removed from sale, and its unique number can no longer be used. The Standard can be withdrawn and not replaced, or it can be withdrawn and replaced by a Standard with a different number.

INFLUENCE OF MATERIALS ON WATER INTENDED FOR HUMAN CONSUMPTION - INFLUENCE DUE TO MIGRATION - PART 2: TEST METHOD FOR NON-METALLIC AND NON-CEMENTITIOUS SITE-APPLIED MATERIALS

Withdrawn date

01-27-2022

Published date

01-01-2005

Foreword
Introduction
1 Scope
2 Normative references
3 Terms and definitions
4 Principle
5 Reagents
   5.1 General
   5.2 Waters to be used for testing
   5.3 Cleaning liquids for glassware
   5.4 Other reagents
6 Apparatus
7 Test pieces
   7.1 General requirements
   7.2 Requirements for the preparation of test piece
        7.2.1 Site-applied organic lining systems for pipes
        7.2.2 Jointing compounds (solvent cements, adhesives)
        7.2.3 Other site-applied materials (e.g. greases and
              sealants)
   7.3 Surface-area-to-volume ratio (S/V)
8 Pretreatment of test pieces
   8.1 General
   8.2 Test pieces to be tested at (23 +/- 2) degree C
        8.2.1 Flushing
        8.2.2 Stagnation with test water
        8.2.3 Stagnation with disinfection treatment water
   8.3 Test pieces to be tested at elevated temperature (60
        degree C to 85 degree C)
        8.3.1 Flushing
        8.3.2 Stagnation with disinfection treatment water at
              (23 +/- 2) degree C
        8.3.3 Stagnation with test water at elevated temperature
   8.4 Prewashing
9 Test procedure
   9.1 Migration of substances
   9.2 Procedural blank tests
   9.3 Analysis
10 Calculation of test results
   10.1 Calculation of the concentration of the substances
        in the migration water
   10.2 Calculation of the migration rate of the measured
        substances
   10.3 Calculation of the mean migration rate
11 Test report
   11.1 General information
   11.2 Information on the material
   11.3 Information on the test pieces
   11.4 Information on the test procedure
   11.5 Test results
Annex A (informative) Arrangement for flushing pipes with nominal
                      size greater than DN 80
Annex B (normative) Additional procedure for testing non-homogeneous
                      products and pipes with nominal size
                      greater than DN 80
                      B.1 Arrangement for testing
                      B.2 Flushing of the test piece
                      B.3 Blank test
Annex C (informative) Sequence of additional migration periods
                      in the migration test
                      C.1 Introduction
                      C.2 Migration tests
Annex D (informative) Procedural tests using standard additions
                      (positive controls)
Annex E (informative) Flow diagrams for migration test procedure
                      for cold water temperature and elevated
                      temperature

Defines a procedure to determine the migration of substances from non-metallic and non-cementitious site-applied materials for use in contact with water intended for human consumption.

DocumentType
Standard
PublisherName
Ente Nazionale Italiano di Unificazione (UNI)
Status
Withdrawn
SupersededBy

View more information
Sorry this product is not available in your region.

Access your standards online with a subscription

Features

  • Simple online access to standards, technical information and regulations.

  • Critical updates of standards and customisable alerts and notifications.

  • Multi-user online standards collection: secure, flexible and cost effective.