UNI EN 54-16 : 2008

Current
Current

The latest, up-to-date edition.

FIRE DETECTION AND FIRE ALARM SYSTEMS - PART 16: VOICE ALARM CONTROL AND INDICATING EQUIPMENT
Published date

08-06-2008

Foreword
Introduction
1 Scope
2 Normative references
3 Terms, definitions and abbreviations
   3.1 Terms and definitions
   3.2 Abbreviations
4 General requirements
   4.1 General
   4.2 Combined VACIE and CIE
   4.3 Power supply
5 General requirements for indications
   5.1 Display and functional conditions
   5.2 Indication display
   5.3 Indication on alphanumeric displays
   5.4 Indication of the supply of power
   5.5 Additional indications
6 The quiescent condition
7 The voice alarm condition
   7.1 Reception and processing of fire signals
   7.2 Indication of the voice alarm condition
   7.3 Audible warning (option with requirements)
   7.4 Delays to entering the voice alarm condition (option
         with requirements)
   7.5 Phased evacuation (option with requirements)
   7.6 Silencing of the voice alarm condition
   7.7 Reset of the voice alarm condition
   7.8 Output to fire alarm devices (option with
         requirements)
   7.9 Voice alarm condition output (option with
         requirements)
8 Fault warning condition
   8.1 Reception and processing of fault signals
   8.2 Indication of faults in specified functions
   8.3 Indication of faults related to the transmission path
         to the CIE (option with requirements)
   8.4 Indication of faults related to voice alarm zones
         (option with requirements)
   8.5 System fault
   8.6 Audible indication
   8.7 Reset of fault indications
   8.8 Transmission of the fault warning condition
9 Disablement condition (option with requirements)
   9.1 General requirements
   9.2 Indication of the disabled condition
   9.3 Indication of specific disablements
   9.4 Disablements and their indication
   9.5 Transmission of the disablement condition
10 Voice alarm manual control (option with requirements)
   10.1 General requirements
   10.2 Indication of the voice alarm zones in an activated
         condition
   10.3 Indication of the voice alarm zones in fault condition
   10.4 Indication of the voice alarm zones in disablement
         condition
11 Interface to external control device(s) (option with the
   requirements)
12 Emergency microphone(s) (option with requirements)
13 Design requirements
   13.1 General requirements and manufacturer's declaration
   13.2 Documentation
   13.3 Mechanical design requirements
   13.4 Electrical and other design requirements
   13.5 Integrity of transmission paths
   13.6 Accessibility of indications and controls
   13.7 Indications by means of light emitting indicators
   13.8 Indications on alphanumeric displays
   13.9 Indication colours
   13.10 Audible indications
   13.11 Indicator testing
   13.12 Audio performance
   13.13 Message store(s)
   13.14 Redundant power amplifiers (option with requirements)
14 Additional design requirements for software controlled
   VACIE
   14.1 General requirements and manufacturer's declarations
   14.2 Software documentation
   14.3 Software design
   14.4 Program monitoring
   14.5 The storage of programs and data
   14.6 Monitoring of memory contents
15 Marking
16 Tests
   16.1 General
   16.2 Functional tests
   16.3 Audio performance and environmental tests
   16.4 Output power
   16.5 Signal-to-noise ratio
   16.6 Frequency response of VACIE without microphone(s)
   16.7 Frequency response of VACIE with microphone(s)
   16.8 Cold (operational)
   16.9 Damp heat, steady state (operational)
   16.10 Damp heat, steady state (endurance)
   16.11 Impact (operational)
   16.12 Vibration, sinusoidal (operational)
   16.13 Vibration, sinusoidal (endurance)
   16.14 Supply voltage variation (operational)
   16.15 Electromagnetic Compatibility (EMC), Immunity tests
         (operational)
Annex A (informative) - Explanation of access level
Annex B (informative) - Optional functions with requirements
        and alternatives
Annex C (informative) - Design requirements for software
        controlled VACIE
Annex D (informative) - General information about voice alarm
        systems
Annex E (informative) - Interface between the VACIE and the CIE
Annex F (informative) - Common indications, controls and
        outputs when the VACIE and the CIE are combined
Annex ZA (informative) - Clauses of this European Standard
         addressing the provisions of the EU Construction
         Products Directive (89/106/EEC)
Bibliography

Describes requirements, methods of test and performance criteria for voice alarm control and indicating equipment for use in fire detection and fire alarm systems installed in buildings, where the alarm signal is in the form of tone(s) or voice message(s), or both.

Committee
CT 34
DocumentType
Test Method
PublisherName
Ente Nazionale Italiano di Unificazione (UNI)
Status
Current

Standards Relationship
EN 54-16:2008 Identical

UNI 11224 : 2011 INITIAL VERIFICATION AND MAINTENANCE OF AUTOMATIC FIRE DETECTION AND FIRE ALARM SYSTEMS
UNI 9795 : 2013 AUTOMATIC FIRE DETECTION AND FIRE ALARM SYSTEMS - DESIGN, INSTALLATION AND OPERATION

EN 60068-2-75:2014 Environmental testing - Part 2-75: Tests - Test Eh: Hammer tests
IEC 60068-1:2013 Environmental testing - Part 1: General and guidance
EN 60068-2-1:2007 Environmental testing - Part 2-1: Tests - Test A: Cold
EN 60068-1:2014 Environmental testing - Part 1: General and guidance
EN 54-2:1997/A1:2006 FIRE DETECTION AND FIRE ALARM SYSTEMS - PART 2: CONTROL AND INDICATING EQUIPMENT
IEC 60068-2-47:2005 Environmental testing - Part 2-47: Test - Mounting of specimens for vibration, impact and similar dynamic tests
EN ISO 9001:2015 Quality management systems - Requirements (ISO 9001:2015)
IEC 60529:1989+AMD1:1999+AMD2:2013 CSV Degrees of protection provided by enclosures (IP Code)
EN 60268-4:2014 Sound system equipment - Part 4: Microphones
IEC 60268-1:1985 Sound system equipment. Part 1: General
ISO 9001:2015 Quality management systems — Requirements
EN 60068-2-78:2013 Environmental testing - Part 2-78: Tests - Test Cab: Damp heat, steady state
IEC 60721-3-3:1994+AMD1:1995+AMD2:1996 CSV Classification of environmental conditions - Part 3-3: Classification of groups of environmental parameters and their severities - Stationary use at weatherprotected locations
EN 60068-2-6:2008 Environmental testing - Part 2-6: Tests - Test Fc: Vibration (sinusoidal)
IEC 60068-2-75:2014 Environmental testing - Part 2-75: Tests - Test Eh: Hammer tests
IEC 60068-2-1:2007 Environmental testing - Part 2-1: Tests - Test A: Cold
EN 50130-4:2011/A1:2014 ALARM SYSTEMS - PART 4: ELECTROMAGNETIC COMPATIBILITY - PRODUCT FAMILY STANDARD: IMMUNITY REQUIREMENTS FOR COMPONENTS OF FIRE, INTRUDER, HOLD UP, CCTV, ACCESS CONTROL AND SOCIAL ALARM SYSTEMS
EN 60529:1991/AC:2016-12 DEGREES OF PROTECTION PROVIDED BY ENCLOSURES (IP CODE) (IEC 60529 EDITION 2.2 CORRIGENDUM 2:2015)
EN 54-4:1997/A2:2006 FIRE DETECTION AND FIRE ALARM SYSTEMS - PART 4: POWER SUPPLY EQUIPMENT
EN 54-1:2011 Fire detection and fire alarm systems - Part 1: Introduction
IEC 61260:1995 Electroacoustics - Octave-band and fractional-octave-band filters
EN 61260:1995/A1:2001 ELECTROACOUSTICS - OCTAVE-BAND AND FRACTIONAL-OCTAVE-BAND FILTERS
IEC 60268-4:2014 Sound system equipment - Part 4: Microphones
EN 60068-2-47:2005 Environmental testing - Part 2-47: Tests - Mounting of specimens for vibration, impact and similar dynamic tests
EN 60721-3-3 : 95 AMD 2 97 CLASSIFICATION OF ENVIRONMENTAL CONDITIONS - CLASSIFICATION OF GROUPS OF ENVIRONMENTAL PARAMETERS AND THEIR SEVERITIES - STATIONARY USE AT WEATHER-PROTECTED LOCATIONS

View more information
Sorry this product is not available in your region.

Access your standards online with a subscription

Features

  • Simple online access to standards, technical information and regulations.

  • Critical updates of standards and customisable alerts and notifications.

  • Multi-user online standards collection: secure, flexible and cost effective.