• There are no items in your cart

VDE 0281-1 : 2003

Superseded

Superseded

A superseded Standard is one, which is fully replaced by another Standard, which is a new edition of the same Standard.

View Superseded by
superseded

A superseded Standard is one, which is fully replaced by another Standard, which is a new edition of the same Standard.

CABLES OF RATED VOLTAGES UP TO AND INCLUDING 450/750 V AND HAVING THERMOPLASTIC INSULATION - PART 1: GENERAL REQUIREMENTS

Superseded date

01-01-2012

Published date

01-12-2013

Vorwort
1 Allgemeines
  1.1 Anwendungsbereich
  1.2 Zweck
  1.3 Gemeinsame Kennzeichnung
2 Definitionen
  2.1 Definitionen für Isolier- und Mantelmischungen
  2.2 Definitionen für Prüfverfahren
  2.3 Nennspannung
3 Kennzeichnung
  3.1 Ursprungskennzeichnung
  3.2 Kennzeichenfolge
  3.3 Beständigkeit
  3.4 Lesbarkeit
  3.5 Gemeinsame Kennzeichnung
  3.6 Verwendung des Wortes CENELEC
4 Aderkennzeichnung
  4.1 Allgemeine Anforderungen
  4.2 Farbschema
  4.3 Farbkombination grün-gelb
  4.4 Aderkennzeichnung flexibler Leitungen durch
      Aufdruck
5 Allgemeine Anforderungen an den Aufbau der Leitungen
  5.1 Leiter
  5.2 Isolierhülle
  5.3 Zwickelfüllung
  5.4 Extrudierte gemeinsame Aderumhüllung
  5.5 Mantel
  5.6 Prüfungen an dervollständigen Leitung
6 Hinweise für die Verwendung
Anhang A (normativ) Normative Verweisungen auf
         internationale Publikationen mit ihren
         entsprechenden europäischen Publikationen
Anhang B (informativ) Nationale Kennzeichnung

Diese Norm gilt für Leitungen und feste Verlegung und flexible Leitungen mit Isolierhülle und, sofern vorhanden, Mantel aus thermoplastischen Werkstoffen mit Nennspannung U[0]/U bis zu 450/750 V für Starkstromanlagen. Es werden die allgemeinen Anforderungen für diese Leitungen festgelegt.

DocumentType
Standard
PublisherName
Verband Deutscher Elektrotechniker
Status
Superseded
SupersededBy

Standards Relationship
DIN VDE 0281-1 : 2003 Identical
HD 21.1 : 200S4 Identical

DIN VDE 0281-3 : 2001 AMD 2 2009 POLYVINYL CHLORIDE INSULATED CABLES OF RATED VOLTAGES UP TO AND INCLUDING 450/750 V - PART 3: NON SHEATHED CABLES FOR FIXED WIRING
DIN 47727:1983-03 CABLES AND FLEXIBLE CORDS FOR POWER INSTALLATION - PVC-SINGLE-CORE NON-SHEATHED CABLE 07V - DIMENSIONS, DESIGNATION, WEIGHTS AND PACKAGING-REQUIREMENT
VDE 0281-107 : 1990 PVC CABLES, WIRES AND FLEXIBLE CORDS FOR POWER INSTALLATION - PVC SINGLE CORE NONSHEATHED CABLE, COLD RESISTING
DIN EN 1870-16:2013-01 SAFETY OF WOODWORKING MACHINES - CIRCULAR SAWING MACHINES - PART 16: DOUBLE MITRE SAWING MACHINES FOR V CUTTING
DIN EN 81-2:2000-05 SAFETY RULES FOR THE CONSTRUCTION AND INSTALLATION OF LIFTS - PART 2: HYDRAULIC LIFTS
DIN EN 1870-2:1999-07 SAFETY OF WOODWORKING MACHINES - CIRCULAR SAWING MACHINES - PART 2: HORIZONTAL BEAM PANEL SAWS AND VERTICAL PANEL SAWS
DIN VDE 0281-8 : 2000 POLYVINYL CHLORIDE INSULATED CABLES OF RATED VOLTAGES UP TO AND INCLUDING 450/750 V - PART 8: SINGLE CORE NON-SHEATHED CABLES FOR DECORATIVE CHAINS
VDE 0166 : 81 AMD 1 87 ELECTRICAL INSTALLATIONS AND APPARATUS THEREOF FOR USE IN ATMOSPHERES POTENTIALLY ENDANGERED BY EXPLOSIVE MATERIAL
VDE 0281-8 : 2000 POLYVINYL CHLORIDE INSULATED CABLES OF NOMINAL VOLTAGES UP TO AND INCLUDING 450/750 V - PART 8: SINGLE CORE NON-SHEATHED CABLES FOR DECORATIVE CHAINS
VDE 0281-9 : 2001 POLYVINYL CHLORIDE INSULATED CABLES OF RATED VOLTAGES UP TO AND INCLUDING 450/750 V - PART 9: SINGLE CORE NON-SHEATHED CABLES FOR INSTALLATION AT LOW TEMPERATURES
VDE 0281-3 : 2001 AMD 2 2009 POLYVINYL CHLORIDE INSULATED CABLES OF RATED VOLTAGES UP TO AND INCLUDING 450/750 V - PART 3: NON SHEATHED CABLES FOR FIXED WIRING
VDE 0250-204 : 2000
VDE 0281-7 : 2001 POLYVINYL CHLORIDE INSULATED CABLES OF RATED VOLTAGES UP TO AND INCLUDING 450/750 V - PART 7: SINGLE CORE NON-SHEATHED CABLES FOR INTERNAL WIRING FOR CONDUCTOR TEMPERATURE OF 90 DEGREES C
DIN VDE 0250-204 : 2000 CABLES, WIRES AND CORDS FOR POWER INSTALLATION - PVC-INSTALLATION CABLE NYM
DIN VDE 0281-7 : 2001 POLYVINYL CHLORIDE INSULATED CABLES OF RATED VOLTAGES UP TO AND INCLUDING 450/750 V - SINGLE CORE NON-SHEATHED CABLES FOR INTERNAL WIRING FOR CONDUCTOR TEMPERATURE OF 90 DEGREE C POUR FILERIE INTERNE
DIN EN 81-2:2010-08 SAFETY RULES FOR THE CONSTRUCTION AND INSTALLATION OF LIFTS - PART 2: HYDRAULIC LIFTS
DIN EN 81-1:2010-06 SAFETY RULES FOR THE CONSTRUCTION AND INSTALLATION OF LIFTS - PART 1: ELECTRIC LIFTS
DIN EN 81-1:2000-05 SAFETY RULES FOR THE CONSTRUCTION AND INSTALLATION OF LIFTS - PART 1: ELECTRIC LIFTS

View more information
Sorry this product is not available in your region.

Access your standards online with a subscription

Features

  • Simple online access to standards, technical information and regulations.

  • Critical updates of standards and customisable alerts and notifications.

  • Multi-user online standards collection: secure, flexible and cost effective.