BS 5410-2 - CODE OF PRACTICE FOR OIL FIRING - PART 2: INSTALLATIONS PROVIDING SPACE HEATING, HOT WATER AND STEAM SUPPLY SERVICES TO NON-DOMESTIC BUILDINGS

Available format(s)

Hardcopy , PDF

Language(s)

English

Foreword
1 Scope
2 Normative references
3 Terms and definitions
4 Work undertaken in connection with liquid
   fuelled installations
5 Classification of fuels
6 Application of oil burners
7 Design and construction of accommodation for
   liquid fuelled installations
8 Oil storage systems
9 Positioning and protection for oil storage and
   service tanks
10 Installation of oil storage tanks
11 Oil handling system from storage tank to burner
12 Storage of kerosene at non-domestic buildings
13 Chimney and flue systems
14 Electrical equipment
15 Instrumentation
16 Commissioning, performance tests and handover
17 Maintenance
18 Maintenance personnels responsibilities
19 Safety provisions
20 Biofuels
Annexes
Annex A (normative) - Choice of class of liquid fuel
Annex B (normative) - Selection of burners
Bibliography

BS 5410-2.

Committee
RHE/13
DocumentType
Draft
Pages
96
PublisherName
British Standards Institution
Status
NA

BS 845-1:1987 Methods for assessing thermal performance of boilers for steam, hot water and high temperature heat transfer fluids Concise procedure
BS EN 13341 : 2005 STATIC THERMOPLASTIC TANKS FOR ABOVE GROUND STORAGE OF DOMESTIC HEATING OILS, KEROSENE AND DIESEL FUELS - BLOW MOULDED AND ROTATIONALLY MOULDED POLYETHYLENE TANKS AND ROTATIONALLY MOULDED TANKS MADE OF ANIONICALLY POLYMERIZED POLYAMIDE 6 - REQUIREMENTS AND TEST METHODS
BS EN 62271-106:2011 High-voltage switchgear and controlgear Alternating current contactors, contactor-based controllers and motor-starters
BS EN 13959:2004 Anti-pollution check valves. DN 6 to DN 250 inclusive Family E, type A, B, C, and D
BS EN 13842:2004 Oil fired forced convection air heaters. Stationary and transportable for space heating
BS EN 1857 : 2003 CHIMNEYS - COMPONENTS - CONCRETE FLUE LINERS
BS EN 13077:2008 Devices to prevent pollution by backflow of potable water. Air gap with non-circular overflow (unrestricted). Family A. Type B
BS 9999:2017 Fire safety in the design, management and use of buildings. Code of practice
BS 6880-2:1988 Code of practice for low temperature hot water heating systems of output greater than 45 kW Selection of equipment
BS EN 303-2:2017 Heating boilers Heating boilers with forced draught burners. Special requirements for boilers with atomizing oil burners
BS EN 303-1:2017 Heating boilers Heating boilers with forced draught burners. Terminology, general requirements, testing and marking
BS EN 60079-15:2010 Explosive atmospheres Equipment protection by type of protection \'n\'
BS EN 12285-1:2003 Workshop fabricated steel tanks Horizontal cylindrical single skin and double skin tanks for the underground storage of flammable and non-flammable water polluting liquids
SAE J 513 : 1999 REFRIGERATION TUBE FITTINGS - GENERAL SPECIFICATIONS
BS EN 303-4:1999 Heating boilers. Heating boilers with forced draught burners Heating boilers with forced draught burners. Special requirements for boilers with forced draught oil burners with outputs up to 70 kW and a maximum operating pressure of 3 bar. Terminology, special requirements, testing and marking
BS EN 13069:2005 Chimneys. Clay/ceramic outer walls for system chimneys. Requirements and test methods
BS EN 12285-2:2005 Workshop fabricated steel tanks Horizontal cylindrical single skin and double skin tanks for the aboveground storage of flammable and non-flammable water polluting liquids
BS EN 14622:2005 Devices to prevent pollution by backflow of potable water. Air gap with circular overflow (restricted). Family A, type F
BS EN 60079-14:2014 Explosive atmospheres Electrical installations design, selection and erection
BS EN 13076:2003 Devices to prevent pollution by backflow of potable water. Unrestricted air gap. Family A. Type A
BS EN 60079-17:2014 Explosive atmospheres Electrical installations inspection and maintenance
BS EN 267 : 2009 AUTOMATIC FORCED DRAUGHT BURNERS FOR LIQUID FUELS
BS 7860:1996 Specification for carbon monoxide detectors (electrical) for domestic use
BS EN 13831:2007 Closed expansion vessels with built-in diaphragm for installation in water
BS EN 1457:1999 Chimneys. Clay/ceramic flue liners. Requirements and test methods
BS EN 50291:2001 Electrical apparatus for the detection of carbon monoxide in domestic premises. Test methods and performance requirements
BS EN 1856-1:2009 Chimneys. Requirements for metal chimneys System chimney products
BS EN 1567 : 2000 BUILDING VALVES - WATER PRESSURE REDUCING VALVES AND COMBINATION WATER REDUCING VALVES - REQUIREMENTS AND TESTS
BS EN 60947-4-1 : 2010 LOW-VOLTAGE SWITCHGEAR AND CONTROLGEAR - PART 4-1: CONTACTORS AND MOTOR-STARTERS - ELECTROMECHANICAL CONTACTORS AND MOTOR-STARTERS
BS EN 1859 : 2009 CHIMNEYS - METAL CHIMNEYS - TEST METHODS
BS EN 1856-2:2009 Chimneys. Requirements for metal chimneys Metal flue liners and connecting flue pipes
BS EN 13216-1:2004 Chimneys. Test methods for system chimneys General test methods
BS EN 12446:2011 Chimneys. Components. Concrete outer wall elements
BS EN 14125:2013 Thermoplastic and flexible metal pipework for underground installation at petrol filling stations
BS EN ISO 4126-1 : 2013 SAFETY DEVICES FOR PROTECTION AGAINST EXCESSIVE PRESSURE - PART 1: SAFETY VALVES (ISO 4126-1:2013)
BS EN 14214:2012 LIQUID PETROLEUM PRODUCTS - FATTY ACID METHYL ESTERS (FAME) FOR USE IN DIESEL ENGINES AND HEATING APPLICATIONS - REQUIREMENTS AND TEST METHODS

View more information
$39.22
Including GST where applicable

Access your standards online with a subscription

Features

  • Simple online access to standards, technical information and regulations.

  • Critical updates of standards and customisable alerts and notifications.

  • Multi-user online standards collection: secure, flexible and cost effective.

Need help?
Call us on 131 242, then click here to start a Screen Sharing session
so we can help right away! Learn more