Standard Practice for Installation of Folded/Formed Poly (Vinyl Chloride) (PVC) Pipe Type A for Existing Sewer and Conduit Rehabilitation

Available format(s)

Hardcopy , PDF

Superseded date

11-11-2014

Language(s)

English

Published date

15-03-2006

CONTAINED IN VOL. 08.04, 2018 Defines the procedures for the rehabilitation of sewer lines and conduits 4 in. (102 mm) to 18 in. (457 mm) in diameter by the insertion of a folded/formed PVC pipe that is heated, pressurized, and expanded to conform to the wall of the original conduit forming a new structural pipe-within-a-pipe.

1.1 This practice covers the procedures for the rehabilitation of sewer lines and conduits 4 in. (102 mm) to 18 in. (457 mm) in diameter by the insertion of a folded/formed PVC pipe that is heated, pressurized, and expanded to conform to the wall of the original conduit forming a new structural pipe-within-a-pipe. This rehabilitation process can be used in a variety of gravity applications such as sanitary sewers, storm sewers, and process piping.

1.2 This practice is to be used with the material specified in Section of Specification F 1871.

1.3 The values stated in inch-pound units are to be regarded as the standard. The SI units given in parentheses are provided for information only.

This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.

1.4 There is no similar or equivalent ISO Standard.

Committee
F 17
DocumentType
Standard Practice
Pages
6
ProductNote
Reconfirmed 2006
PublisherName
American Society for Testing and Materials
Status
Superseded
SupersededBy
Supersedes

ASTM F 1871 : 2018 Standard Specification for Folded/Formed Poly (Vinyl Chloride) Pipe Type A for Existing Sewer and Conduit Rehabilitation

ASTM D 790 : 2017 : REDLINE Standard Test Methods for Flexural Properties of Unreinforced and Reinforced Plastics and Electrical Insulating Materials
ASTM D 2122 : 2016 : REDLINE Standard Test Method for Determining Dimensions of Thermoplastic Pipe and Fittings
ASTM F 1871 : 2011-06 SPECIFICATION FOR FOLDED/FORMED POLY (VINYL CHLORIDE) PIPE TYPE A FOR EXISTING SEWER AND CONDUIT REHABILITATION
ASTM D 648 : 2016 Standard Test Method for Deflection Temperature of Plastics Under Flexural Load in the Edgewise Position
ASTM D 638 : 2014 : REDLINE Standard Test Method for Tensile Properties of Plastics
ASTM D 1784 : 2011 : REDLINE Standard Specification for Rigid Poly(Vinyl Chloride) (PVC) Compounds and Chlorinated Poly(Vinyl Chloride) (CPVC) Compounds

View more information
$122.77
Including GST where applicable

Access your standards online with a subscription

Features

  • Simple online access to standards, technical information and regulations.

  • Critical updates of standards and customisable alerts and notifications.

  • Multi-user online standards collection: secure, flexible and cost effective.

Need help?
Call us on 131 242, then click here to start a Screen Sharing session
so we can help right away! Learn more