BS 6466:1984
Current
The latest, up-to-date edition.
Code of practice for design and installation of ceramic fibre furnace linings
Hardcopy , PDF
English
31-08-1984
Foreword
Committees responsible
Code of practice
Section one. General
1. Scope
2. Definitions
Section two. Design considerations
3. Design criteria
4. Lining systems
5. Anchoring systems
6. Thermal design for steady conditions
7. Thermal design for intermittent heating
8. Protection against erosion, abrasion and corrosion
Section three. Design for installation
9. In situ linings
10. Prefabricated modular linings
Section four. Site arrangements
11. Preparations for installation of ceramic fibre
linings
Section five. Installation procedures
12. Surface preparation, fixing of anchoring and
supporting attachments
13. In situ linings
14. Prefabricated modular linings
15. Veneer systems
Section six. Inspection, testing and repair
16. Inspection and testing
17. Repair techniques
Section seven. Health and safety considerations
18. Potential hazards of man-made mineral fibres
Appendix
A. Text deleted
Tables
1. Maximum tip temperatures for typical metal
anchoring or support components
2. External heat losses and cold face temperatures
3. Table deleted
Figures
1. Twist-lock anchor
2. Threaded anchor
3. Overlapped joint stud pattern (roof)
4. Butt joint stud pattern
5. Shingled joint stud pattern (walls or roof)
6. Layered blanket linings: typical internal corner
detail
7. Layered blanket linings: alternative internal
corner detail
8. Layered blanket linings: external corners
9. Door seal (stacked module on board)
10. Door seal (section through deep door)
11. Door seal (rebated module)
12. Door seal (wall to roof)
13. Side view of furnace showing preferred door
movement
14. Alloy steel box support
15. Steel angle frame
16. Burner block construction
17. Bolted-on vacuum formed burner quarl assembly
18. Support of typical ceramic fibre quarl in ceramic
fibre lining
19. Arrangement of lining around quarl of dense
refractory material
20. Lining construction adjacent to burner quarl when
dimension A - B is > 20 mm
21. Typical anchoring system for stacked module
(group A)
22. Typical pleated module (group A)
23. Typical anchoring system for a furnace construction
module (group B)
24. Typical anchoring system for vacuum formed box type
module (group C)
25. Corner detail of pleated group A module
26. Corner detail for stacked fibre group A module
27. Corner junction using box type group C modules
28. Corner junction using box type group C modules
(alternative design)
29. Corner junction using furnace construction modules
(group B)
30. Door seals for vacuum formed modular construction
31. Typical stud pattern around a small flue opening
32. Typical stud pattern around a large flue opening
33. Typical stud pattern around a burner block
34. Blanket cutter
35. Typical wet felt stud patterns (butt joint)
36. Typical wet felt stud patterns (overlap joints)
37. Typical junction detail between roof and walls
(group C)
38. Fairing steps in refractory prior to veneering
39. Method of anchoring stud into refractory
40. Text deleted
41. Text deleted
42. Text deleted
Access your standards online with a subscription
Features
-
Simple online access to standards, technical information and regulations.
-
Critical updates of standards and customisable alerts and notifications.
-
Multi-user online standards collection: secure, flexible and cost effective.