Customer Support: 131 242

  • There are no items in your cart
We noticed you’re not on the correct regional site. Switch to our AMERICAS site for the best experience.
Dismiss alert

BS 7041:1989

Superseded

Superseded

A superseded Standard is one, which is fully replaced by another Standard, which is a new edition of the same Standard.

View Superseded by
superseded

A superseded Standard is one, which is fully replaced by another Standard, which is a new edition of the same Standard.

Specification for characteristics and calibration of hydrophones for operation in the frequency range 0.5 MHz to 15 MHz

Available format(s)

Hardcopy , PDF

Superseded date

30-05-2008

Language(s)

English

Published date

28-02-1989

National foreword
Committees responsible
List of symbols
1 Scope
2 Object
3 Definitions
3.1 Free field
3.2 Far field
3.3 Acoustic centre
3.4 Hydrophone (or receiver)
3.5 Reversible transducer
3.6 Reciprocal transducer
3.7 Open-circuit voltage at hydrophone
3.8 Free-field sensitivity of a hydrophone
3.9 Free-field sensitivity level
3.10 Transmitting response to current of a projector
3.11 Reciprocity coefficient
3.12 Direction response of a hydrophone
3.13 End-of-cable leakage resistance
3.14 Mechanical Q of hydrophone element
4 General introduction
4.1 Choice of measurement method
4.2 Basis of recommendations
4.3 Effect of the finite size of hydrophones
4.4 Hydrophone calibration
5 Hydrophone characteristics
5.1 Sensitivity
5.2 Directivity
5.3 Electrical characteristics
5.4 Mechanical characteristics
6 Specification of performance of a hydrophone
6.1 Free-field voltage sensitivity
6.2 Directivity
6.3 Electrical aspects
6.4 Mechanical and environmental aspects
7 Hydrophone calibration
7.1 Reciprocity techniques
7.2 Principle of the two-transducer reciprocity method
7.3 Calibration measurement conditions
7.4 Experimental method
7.5 Calculation of results
7.6 Accuracy
Appendices
A Rationale for the reciprocity procedure
B Plane wave reciprocity
C Details of the recommended experimental procedures
D Evaluation of the correction factor, k
E Bibliography
Figures

Defines performance characteristics of hydrophones for use in a specified range of applications, particularly those associated with the measurement of pulsed and continuous-wave ultrasonic fields used in medical diagnosis. Establishes a scheme for specification of performance and standard procedure for calibration.

Committee
EPL/87
DevelopmentNote
Also numbered as IEC 60866. (09/2005)
DocumentType
Standard
Pages
28
PublisherName
British Standards Institution
Status
Superseded
SupersededBy

BS EN 61102:1994 Specification for measurement and characterisation of ultrasonic fields using hydrophones in the frequency range 0.5 MHz to 15 MHz
BS 7887:1997 Ultrasonics. Real-time pulse-echo systems. Guide for test procedures to determine performance specifications
BS EN 61266:1995 Ultrasonics. Hand-held probe Doppler foetal heartbeat detectors. Performance requirements and methods of measurement and reporting
BS EN 61101:1994 Specification for absolute calibration of hydrophones using the planar scanning technique in the frequency range 0,5 MHz to 15 MHz

BS 5652:1979 Specification for the calibration of hydrophones
BS 5653:1978 Specification for hydrophones for calibration purposes

View more information
$407.85
Including GST where applicable

Access your standards online with a subscription

Features

  • Simple online access to standards, technical information and regulations.

  • Critical updates of standards and customisable alerts and notifications.

  • Multi-user online standards collection: secure, flexible and cost effective.

Need help?
Call us on 131 242, then click here to start a Screen Sharing session
so we can help right away! Learn more