FOREWORD
TABLE RECAPITULATING CROSS-REFERENCES
1 Scope
2 Normative references
3 Definitions
4 Measuring apparatus
  4.1 Quasi-peak measuring receivers for the frequency
       range 9 kHz to 1000 MHz
  4.2 Peak measuring receivers for the frequency range
       9 kHz to 1000 MHz
  4.3 Average measuring receivers for the frequency range
       9 kHz to 1000 MHz
  4.4 RMS measuring receivers for the frequency range 9 kHz
       to 1000 MHz
  4.5 Spectrum analyzers and scanning receivers
  4.6 Audio-frequency voltmeter
5 Ancillary apparatus
  5.1 Artificial mains networks
  5.2 Current and voltage probes
  5.3 Absorbing clamp for use in the frequency range 30 MHz
       to 1000 MHz
  5.4 Disturbance analyzers
  5.5 Antennas for measurement of radiated radio disturbance
  5.6 Test sites for measurement of radio disturbance field
       strength for the frequency range of 30 MHz to 1000 MHz
  5.7 Reverberating chamber for total radiated power measurement
  5.8 Coupling units for conducted current immunity measurement
  5.9 TEM cells for immunity to radiated disturbance measurement
  5.10 Coupling devices for measuring signal lines
  5.11 The artificial hand and series RC element
  5.12 Test sites for measurement of radio disturbance field
       strength for the frequency range 1 GHz to 18 GHz
  5.13 Specifications and validation procedures for a test
       site to be used to calibrate antennas in the frequency
       range of 30 MHz to 1000 MHz
Annex A (normative) Determination of response to repeated pulses
        of quasi-peak and r.m.s. measuring receivers (subclauses
        3.2, 4.1.4.2, 4.4.2.2 and 4.4.4.1)
Annex B (normative) Determination of pulse generator spectrum
        (subclauses 4.1.4, 4.2.4, 4.3.4, 4.4.4)
Annex C (normative) Accurate measurements of the output of
        nanosecond pulse generators (subclauses 4.1.4, 4.2.4,
        4.3.4, 4.4.4)
Annex D (normative) Influence of the quasi-peak measuring
        receiver characteristics on its pulse response
        (subclause 4.1.4.2)
Annex E (normative) Response of average and peak measuring
        receivers (subclause 4.3.2.1)
Annex F (normative) Artificial mains networks (subclause 5.1)
Annex G (normative) Validation procedure of the open area test
        site for the frequency range of 30 MHz to 1000 MHz
        (subclause 5.6)
Annex H (normative) Calibration of the absorbing clamp
        (subclause 5.3)
Annex I (informative) Construction, frequency range, and
        calibration of current probes (subclause 5.2)
Annex J (informative) Construction of the absorbing clamp
        (subclause 5.3)
Annex K (informative) Construction details for open area test
        sites in the frequency range of 30 MHz to 1000 MHz
        (subclause 5.6)
Annex L (informative) Basis for 4 dB site acceptability
        criterion (subclause 5.6)
Annex M (informative) Construction of the coupling units for
        current injection for the frequency range 0,15 MHz to
        30 MHz (subclause 5.8)
Annex N (informative) Principle of operation and examples of
        coupling units for conducted current immunity
        measurements (subclause 5.8)
Annex O (normative) Parameters of broadband antennas
Annex P (normative) Loop antenna system for magnetic field
        induced current measurements in the frequency range of
        9 kHz to 30 MHz
Annex Q (normative) Example and measurement of an asymmetrical
        artificial network (AAN)
Annex R (informative) CALTS requirements (subclause 5.13)
Annex S (informative) Test antenna considerations (subclause
        5.13)
Annex T (informative) Antenna and site attenuation theory
        (subclause 5.13)
Annex U (informative) Application of a fixed length dipole
        (30 MHz <= f <= 80 MHz) (subclause 5.13)
Annex V (informative) Pascal Program used in T.1.3 (subclause
        5.13)
Annex W (informative) Checklist validation procedure (subclause
        5.13)
Annex X (normative) Monopole (1 m rod antenna) performance
        equations and characterization of the associated antenna
        matching network
Annex Y (normative) Performance check of the exceptions from the
        definitions of a click according to 4.2.3 of CISPR 14-1
Annex Z (normative) Example and measurement of the parameters of
        the AN for coaxial and other screened cables
Figures 1 to Z.2

Defines characteristics and performance of equipment for measuring radio disturbance voltages, currents and fields in frequency range 9 kHz to 18 GHz. Also defines requirements for specialist equipment for discontinuous disturbance measurements. Includes measurement of broadband and narrowband kinds of radio disturbance.

Committee
GEL/210
DevelopmentNote
Supersedes BS CISPR 16-1(1998) (02/2000) Also numbered as CISPR 16-1 Supersedes 00/242237 DC, 97/217124 DC & & 01/204702 DC (04/2003)
DocumentType
Standard
Pages
234
PublisherName
British Standards Institution
Status
Superseded
SupersededBy
Supersedes

CISPR 14-1:2016 Electromagnetic compatibility - Requirements for household appliances, electric tools and similar apparatus - Part 1: Emission
IEC 60315-3:1989+AMD1:1999 CSV Methods of measurement on radio receivers for various classes of emission - Part 3: Receivers for amplitude-modulated sound-broadcasting emissions
CISPR 16-2:2003 Specification for radio disturbance and immunity measuring apparatus and methods - Part 2: Methods of measurement of disturbances and immunity
IEC 60315-4:1997 Methods of measurement on radio receivers for various classes of emission - Part 4: Receivers for frequency-modulated sound broadcasting emissions
CISPR TR 16-3:2010+AMD1:2012+AMD2:2015 CSV Specification for radio disturbance and immunity measuring apparatus and methods - Part 3: CISPR technical reports

View more information
$733.34
Including GST where applicable

Access your standards online with a subscription

Features

  • Simple online access to standards, technical information and regulations.

  • Critical updates of standards and customisable alerts and notifications.

  • Multi-user online standards collection: secure, flexible and cost effective.

Need help?
Call us on 131 242, then click here to start a Screen Sharing session
so we can help right away! Learn more