CSA C22.2 NO. 60335-2-40:19

Withdrawn

Withdrawn

A Withdrawn Standard is one, which is removed from sale, and its unique number can no longer be used. The Standard can be withdrawn and not replaced, or it can be withdrawn and replaced by a Standard with a different number.

Household and similar electrical appliances — Safety — Part 2-40: Particular requirements for electrical heat pumps, air-conditioners and dehumidifiers (Binational standard UL 60335-2-40)

Available format(s)

Hardcopy , PDF

Withdrawn date

13-01-2023

Language(s)

English

Published date

01-01-2019

This part of IEC 60335 deals with the safety of electric HEAT PUMPS, including SANITARY HOT WATER HEAT PUMPS, AIR CONDITIONERS, and DEHUMIDIFIERS incorporating motor-compressors and HYDRONIC FAN COILS UNITS, their maximum RATED VOLTAGES being not more than 250 V for single phase appliances and 600 V for all other appliances.

Preface This is the harmonized CSA Group and UL standard for Particular Requirements for Electrical Heat Pumps, Air-Conditioners and Dehumidifiers. It is the third edition of CAN/CSA-C22.2 No. 60335-2-40, and the third edition of UL 60335-2-40. This edition of CAN/CSA-C22.2 No. 60335-2-40 supersedes the previous edition (s) published on September 15, 2017. This edition of UL 60335-2-40 supersedes the previous edition(s) published on September 15, 2017. This harmonized standard is based on IEC Publication 60335-2-40: 6.0 edition Household and similar electrical appliances – Safety – Part 2-40: Particular requirements for electrical heat pumps, air-conditioners and dehumidifiers issued January 2018. IEC publication 60035-2-40 is copyrighted by the IEC. This standard has been developed in compliance with Standards Council of Canada requirements for National Standards of Canada. It has been published as a National Standard of Canada by CSA Group. Scope This clause of Part 1 is replaced by the following. This part of IEC 60335 deals with the safety of electric HEAT PUMPS, including SANITARY HOT WATER HEAT PUMPS, AIR CONDITIONERS, and DEHUMIDIFIERS incorporating motor-compressors and HYDRONIC FAN COILS UNITS, their maximum RATED VOLTAGES being not more than 250 V for single phase appliances and 600 V for all other appliances. PARTIAL UNITS are within the scope of this International Standard. Appliances not intended for normal household use but which nevertheless may be a source of danger to the public, such as appliances intended to be used by laymen in shops, in light industry and on farms, are within the scope of this standard. The appliances referenced above may consist of one or more factory-made assemblies. If provided in more than one assembly, the separate assemblies are to be used together, and the requirements are based on the use of matched assemblies. NOTE 101 A definition of ‘motor-compressor’ is given in IEC 60335-2-34, which includes the statement that the term motor-compressor is used to designate either a hermetic motor-compressor or semi-hermetic motor-compressor. NOTE 102 Requirements for refrigerating safety are covered by ISO 5149-1, ISO 5149-2, and ISO 5149-3. Requirements for containers intended for storage of the heated water included in SANITARY HOT WATER HEAT PUMPS are, in addition, covered by IEC 60335-2-21. This standard does not take into account refrigerants other than group A1, A2L, A2 and A3 as defined by ISO 817 classification, A2L REFRIGERANTS are limited to those of a molar mass of more than or equal to 42 kg/kmol based on WCF as specified in ISO 817. This standard specifies particular requirements for the use of FLAMMABLE REFRIGERANTS. Unless specifications are covered by this standard, including the annexes, requirements for refrigerating safety are covered by ISO 5149. The parts of ISO 5149 of particular concern to this standard are as follows: • ISO 5149-1:2014, Refrigerating systems and heat pumps – Safety and environmental requirements – Part 1: Definitions, classification and selection criteria. • ISO 5149-2, Refrigerating systems and heat pumps – Safety and environmental requirements – Part 2: Design, construction, testing, marking and documentation; • ISO 5149-3:2014, Refrigerating systems and heat pumps – Safety and environmental requirements – Part 3: Installation site. SUPPLEMENTARY HEATERS, or a provision for their separate installation, are within the scope of this standard, but only heaters which are designed as a part of the appliance package, the controls being incorporated in the appliance. NOTE 103 Attention is drawn to the fact that • for appliances intended to be used in vehicles or on board ships or aircraft, additional requirements may be necessary; • for appliances subjected to pressure, additional requirements may be necessary; • in many countries, additional requirements are specified, for example, by the national health authorities responsible for the protection of labour and the national authorities responsible for storage, transportation, building constructions and installations. NOTE 104 This standard does not apply to • humidifiers intended for use with heating and cooling equipment (IEC 60335-2-88); • appliances designed exclusively for industrial processing; • appliances intended to be used in locations where special conditions prevail, such as the presence of a corrosive or explosive atmosphere (dust, vapour or gas). 1DV.1 DR Modification by replacing the second paragraph of Clause 1 as follows: This part of IEC 60335 deals with the safety of electric heat pumps, including hot water heat pumps, air conditioners, dehumidifiers, and hydronic fan coils units, their maximum rated voltages being not more than 300 V for single phase appliances and 15 000 V for all other appliances. Partial units are within the scope of this International Standard. 1DV.2 D1 Modification of the sixth paragraph of this Part 2 by replacing with the following: This standard does not take into account refrigerants other than refrigerant safety groups as defined by ISO 817 or ASHRAE 34 as follows: a) A1; and b) B1 (for use in appliances installed in machinery rooms as defined in accordance with ANSI/ASHRAE 15 (USA) or CSA B52 (Canada), or outdoors only); and c) A2L, A2, and A3, refrigerants with a molar mass not less than 42 kg/kmol based on nominal composition. 1DV.3 DR Modification of the eighth paragraph of Clause 1 as follows: Replace \"ISO 5149\" with \"ANSI/ASHRAE 15 (USA) and CSA B52 (Canada)\". 1DV.4 DR Modification of Clause 1 of the Part 2 by adding the following paragraph: All references to ISO 817 in this Part 2 also apply to ANSI/ASHRAE 34. ANSI/ASHRAE 34 shall take precedence over ISO 817. 1DV.5 D1 Modification of NOTE 104 of Clause 1 of the Part 2 by deleting the 2nd bullet point.

DocumentType
Standard
ISBN
978-1-4883-2009-5
Pages
252
ProductNote
THIS STANDARD ALSO REFERS TO CAN/CSA-C22.2 No. 0.17,AHRI 13256,ANSI/ASHRAE 15,ANSI/ASHRAE 34,ANSI/NFPA 90A,ANSI/NFPA 90B,ASME VIII,ASTM A90/A90M,ASTM B344,CAN/ULC-S102,CAN/CSA-C22.2 No. 198.1,CAN/CSA-C22.2 No. 60335-2-34,CAN/CSA-C22.2 No. 61730-1,CAN/CSA-C22.2 No. 61730-2,CAN/CSA-C22.2 No. 62109-1,CAN/CSA-C22.2 No. 62109-2,UL 62109-2,ULC/ORD C1703,CAN/ULC S111
PublisherName
Canadian Standards Association
Status
Withdrawn
Supersedes

View more information
$972.32
Including GST where applicable

Access your standards online with a subscription

Features

  • Simple online access to standards, technical information and regulations.

  • Critical updates of standards and customisable alerts and notifications.

  • Multi-user online standards collection: secure, flexible and cost effective.

Need help?
Call us on 131 242, then click here to start a Screen Sharing session
so we can help right away! Learn more