Customer Support: 131 242

  • There are no items in your cart
We noticed you’re not on the correct regional site. Switch to our AMERICAS site for the best experience.
Dismiss alert

CSA C22.2 NO. 61010-2-010:19

Current

Current

The latest, up-to-date edition.

Safety requirements for electrical equipment for measurement, control and laboratory use — Part 2-010: Particular requirements for laboratory equipment for the heating of materials (Adopted IEC 61010-2-010:2019, fourth edition, 2019-02, with Canadian deviations) | Exigences de sécurité pour appareils électriques de mesurage, de régulation et de laboratoire — Partie 2-010 : Exigences particulières pour appareils de laboratoire utilisés pour l\'échauffement des matières (norme IEC 61010-2-010:2019 adoptée, quatrième édition, 2019-02, avec exigences propres au Canada)

Available format(s)

Hardcopy , PDF

Language(s)

English - French

Published date

01-01-2019

CSA Preface This is the fourth edition of CSA C22.2 No. 61010-2-010, Safety requirements for electrical equipment for measurement, control and laboratory use — Part 2-010: Particular requirements for laboratory equipment for the heating of materials, which is an adoption, with Canadian deviations, of the identically titled IEC (International Electrotechnical Commission) Standard 61010-2-010 (fourth edition, 2019-02). It supersedes the previous edition published in 2015 as CAN/CSA-C22.2 No. 61010-2-010 (adopted IEC 61010-2-010:2014). It is one in a series of Standards issued by CSA Group under Part II of the Canadian Electrical Code. For brevity, this Standard will be referred to as \"CSA C22.2 No. 61010-2-010\" throughout. This Standard is intended to be used in conjunction with CAN/CSA-C22.2 No. 61010-1:12, Safety requirements for electrical equipment for measurement, control, and laboratory use — Part 1: General requirements (adopted IEC 61010-1:2010, with Canadian and US deviations); and Amendment 1:2018 to CAN/CSA-C22.2 No. 61010-1:12 (adopted IEC Amendment 1:2016, with Canadian and US deviations). This Standard has been developed in compliance with Standards Council of Canada requirements for National Standards of Canada. It has been published as a National Standard of Canada by CSA Group. Scope and object This clause of Part 1 is applicable except as follows: 1.1.1 Equipment included in scope Replacement: Replace the second paragraph by the following: This part of IEC 61010 specifies particular safety requirements for the following types a) to c) of electrical equipment and their accessories, wherever they are intended to be used, whenever the heating of materials is one of the functions of the equipment. Addition: Add the following text after item c): It is possible that all or part of the equipment falls within the scope of one or more other Part 2 standards of IEC 61010 as well as within the scope of this standard. In that case, the requirements of those other Part 2 standards will also apply. In particular, if equipment is intended to be used for in vitro diagnostic (IVD) purposes, the requirements of IEC 610102101 will also apply. However, when the equipment incorporates a refrigerating system and a heating function where the combination of the two introduces additional or more severe HAZARDS than if treated separately, then it is possible that IEC 61010-2-012 is applicable instead of this Part 2-010. See further information in the flow chart (Figure 102) for the selection process and the guidance in the Introduction. 1.1.2 Equipment excluded from scope Addition: Add the following items after item j): aa) equipment for the heating and ventilation of laboratories; bb) sterilizing equipment; cc) heating and/or cooling equipment which the OPERATOR is intended to enter, and which is large enough for the OPERATOR to remain inside with the door or doors closed. -------------------------------------------------------------------------------------------------------------------------------- Préface CSA Ce document constitue la quatrième édition de CSA C22.2 nº 61010-2-010, Exigences de sécurité pour appareils électriques de mesurage, de régulation et de laboratoire — Partie 2-010 : Exigences particulières pour appareils de laboratoire utilisés pour l\'échauffement des matières. Il s’agit de l’adoption, avec exigences propres au Canada, de la norme IEC (Commission Électrotechnique Internationale) 61010-2-010 (quatrième édition, 2019-02), qui porte le même titre. Il remplace l\'édition antérieure publiée en 2015 qui portait la désignation CAN/CSA-C22.2 nº 61010-2-010 (norme IEC 61010-2-010:2014 adoptée). Il fait partie d’une série de normes publiées par Groupe CSA qui constituent le Code canadien de l’électricité, Deuxième partie. Par souci de brièveté, tout au long de ce document, il sera appelé « CSA C22.2 nº 61010-2-010 ». Cette norme est conçue pour être utilisée de concert avec CAN/CSA-C22.2 nº 61010-1:12, Règles de sécurité pour appareils électriques de mesurage, de régulation et de laboratoire — Partie 1 : Exigences générales (norme IEC 61010-1:2010 adoptée, avec exigences propres au Canada et aux États-Unis); et Modification 1:2018 à CAN/CSA-C22.2 nº 61010-1:12 (IEC Amendement 1:2016 adopté, avec exigences propres au Canada et aux États-Unis). Cette norme a été élaborée conformément aux exigences du Conseil canadien des normes concernant les Normes nationales du Canada. Cette norme a été publiée en tant que Norme nationale du Canada par Groupe CSA. Domaine d\'application et objet L\'article de la Partie 1 est applicable à l\'exception de ce qui suit: 1.1.1 Appareils inclus dans le domaine d\'application Remplacement: Remplacer le deuxième alinéa par ce qui suit: La présente partie de l\'IEC 61010 spécifie les exigences de sécurité particulières pour les appareils électriques et leurs accessoires des types a) à c) suivants, quelle que soit l\'utilisation à laquelle ils sont destinés, lorsque l\'échauffement des matières est l\'une des fonctions de l\'appareil. Addition: Ajouter le texte suivant après le point c): Il est possible qu\'une ou toutes les parties de l\'appareil relèvent du domaine d\'application d\'une ou plusieurs autres Parties 2 de l\'IEC 61010, ainsi que du domaine d\'application de la présente norme. En particulier, si l\'appareil est prévu pour être utilisé pour l\'IVD, les exigences de l\'IEC 610102101 s\'appliquent également. Toutefois, lorsque l\'appareil comprend un système frigorifique et une fonction de chauffage dont la combinaison des deux introduit des dangers supplémentaires ou plus graves que lorsque le traitement est réalisé séparément, alors il est possible que l\'IEC 61010-2-012 soit applicable à la place de la présente Partie 2-010. De plus amples informations sur le processus de sélection sont données dans l\'organigramme (Figure 102) et des recommandations sont données dans l\'Introduction. 1.1.2 Appareils exclus du domaine d\'application Addition: Ajouter les points suivants après le point j): aa) appareils pour l\'échauffement et la ventilation des laboratoires; bb) appareils de stérilisation; cc) appareil de chauffage et/ou de refroidissement à l\'intérieur duquel il est prévu que l\'OPERATEUR entre, et qui est assez grand pour que l\'OPERATEUR puisse s\'y tenir avec la ou les portes fermées.

CSA Preface This is the fourth edition of CSA C22.2 No. 61010-2-010, Safety requirements for electrical equipment for measurement, control and laboratory use — Part 2-010: Particular requirements for laboratory equipment for the heating of materials, which is an adoption, with Canadian deviations, of the identically titled IEC (International Electrotechnical Commission) Standard 61010-2-010 (fourth edition, 2019-02). It supersedes the previous edition published in 2015 as CAN/CSA-C22.2 No. 61010-2-010 (adopted IEC 61010-2-010:2014). It is one in a series of Standards issued by CSA Group under Part II of the Canadian Electrical Code. For brevity, this Standard will be referred to as \"CSA C22.2 No. 61010-2-010\" throughout. This Standard is intended to be used in conjunction with CAN/CSA-C22.2 No. 61010-1:12, Safety requirements for electrical equipment for measurement, control, and laboratory use — Part 1: General requirements (adopted IEC 61010-1:2010, with Canadian and US deviations); and Amendment 1:2018 to CAN/CSA-C22.2 No. 61010-1:12 (adopted IEC Amendment 1:2016, with Canadian and US deviations). This Standard has been developed in compliance with Standards Council of Canada requirements for National Standards of Canada. It has been published as a National Standard of Canada by CSA Group. Scope and object This clause of Part 1 is applicable except as follows: 1.1.1 Equipment included in scope Replacement: Replace the second paragraph by the following: This part of IEC 61010 specifies particular safety requirements for the following types a) to c) of electrical equipment and their accessories, wherever they are intended to be used, whenever the heating of materials is one of the functions of the equipment. Addition: Add the following text after item c): It is possible that all or part of the equipment falls within the scope of one or more other Part 2 standards of IEC 61010 as well as within the scope of this standard. In that case, the requirements of those other Part 2 standards will also apply. In particular, if equipment is intended to be used for in vitro diagnostic (IVD) purposes, the requirements of IEC 610102101 will also apply. However, when the equipment incorporates a refrigerating system and a heating function where the combination of the two introduces additional or more severe HAZARDS than if treated separately, then it is possible that IEC 61010-2-012 is applicable instead of this Part 2-010. See further information in the flow chart (Figure 102) for the selection process and the guidance in the Introduction. 1.1.2 Equipment excluded from scope Addition: Add the following items after item j): aa) equipment for the heating and ventilation of laboratories; bb) sterilizing equipment; cc) heating and/or cooling equipment which the OPERATOR is intended to enter, and which is large enough for the OPERATOR to remain inside with the door or doors closed. -------------------------------------------------------------------------------------------------------------------------------- Préface CSA Ce document constitue la quatrième édition de CSA C22.2 nº 61010-2-010, Exigences de sécurité pour appareils électriques de mesurage, de régulation et de laboratoire — Partie 2-010 : Exigences particulières pour appareils de laboratoire utilisés pour l\'échauffement des matières. Il s’agit de l’adoption, avec exigences propres au Canada, de la norme IEC (Commission Électrotechnique Internationale) 61010-2-010 (quatrième édition, 2019-02), qui porte le même titre. Il remplace l\'édition antérieure publiée en 2015 qui portait la désignation CAN/CSA-C22.2 nº 61010-2-010 (norme IEC 61010-2-010:2014 adoptée). Il fait partie d’une série de normes publiées par Groupe CSA qui constituent le Code canadien de l’électricité, Deuxième partie. Par souci de brièveté, tout au long de ce document, il sera appelé « CSA C22.2 nº 61010-2-010 ». Cette norme est conçue pour être utilisée de concert avec CAN/CSA-C22.2 nº 61010-1:12, Règles de sécurité pour appareils électriques de mesurage, de régulation et de laboratoire — Partie 1 : Exigences générales (norme IEC 61010-1:2010 adoptée, avec exigences propres au Canada et aux États-Unis); et Modification 1:2018 à CAN/CSA-C22.2 nº 61010-1:12 (IEC Amendement 1:2016 adopté, avec exigences propres au Canada et aux États-Unis). Cette norme a été élaborée conformément aux exigences du Conseil canadien des normes concernant les Normes nationales du Canada. Cette norme a été publiée en tant que Norme nationale du Canada par Groupe CSA. Domaine d\'application et objet L\'article de la Partie 1 est applicable à l\'exception de ce qui suit: 1.1.1 Appareils inclus dans le domaine d\'application Remplacement: Remplacer le deuxième alinéa par ce qui suit: La présente partie de l\'IEC 61010 spécifie les exigences de sécurité particulières pour les appareils électriques et leurs accessoires des types a) à c) suivants, quelle que soit l\'utilisation à laquelle ils sont destinés, lorsque l\'échauffement des matières est l\'une des fonctions de l\'appareil. Addition: Ajouter le texte suivant après le point c): Il est possible qu\'une ou toutes les parties de l\'appareil relèvent du domaine d\'application d\'une ou plusieurs autres Parties 2 de l\'IEC 61010, ainsi que du domaine d\'application de la présente norme. En particulier, si l\'appareil est prévu pour être utilisé pour l\'IVD, les exigences de l\'IEC 610102101 s\'appliquent également. Toutefois, lorsque l\'appareil comprend un système frigorifique et une fonction de chauffage dont la combinaison des deux introduit des dangers supplémentaires ou plus graves que lorsque le traitement est réalisé séparément, alors il est possible que l\'IEC 61010-2-012 soit applicable à la place de la présente Partie 2-010. De plus amples informations sur le processus de sélection sont données dans l\'organigramme (Figure 102) et des recommandations sont données dans l\'Introduction. 1.1.2 Appareils exclus du domaine d\'application Addition: Ajouter les points suivants après le point j): aa) appareils pour l\'échauffement et la ventilation des laboratoires; bb) appareils de stérilisation; cc) appareil de chauffage et/ou de refroidissement à l\'intérieur duquel il est prévu que l\'OPERATEUR entre, et qui est assez grand pour que l\'OPERATEUR puisse s\'y tenir avec la ou les portes fermées.

DocumentType
Standard
ISBN
978-1-4883-2621-9
Pages
76
PublisherName
Canadian Standards Association
Status
Current
Supersedes

View more information
$406.85
Including GST where applicable

Access your standards online with a subscription

Features

  • Simple online access to standards, technical information and regulations.

  • Critical updates of standards and customisable alerts and notifications.

  • Multi-user online standards collection: secure, flexible and cost effective.

Need help?
Call us on 131 242, then click here to start a Screen Sharing session
so we can help right away! Learn more