EN 1999-1-4:2007

Withdrawn

Withdrawn

A Withdrawn Standard is one, which is removed from sale, and its unique number can no longer be used. The Standard can be withdrawn and not replaced, or it can be withdrawn and replaced by a Standard with a different number.

Eurocode 9 - Design of aluminium structures - Part 1-4: Cold-formed structural sheeting

Withdrawn date

31-03-2010

Published date

28-02-2007

1.1.1Scope of EN 1999(1)PEN 1999 applies to the design of buildings and civil engineering and structural works in aluminium. It complies with the principles and requirements for the safety and serviceability of structures, the basis of their design and verification that are given in EN 1990 - Basis of structural design.(2)EN 1999 is only concerned with requirements for resistance, serviceability, durability and fire resis¬tance of aluminium structures. Other requirements, e.g. concerning thermal or sound insulation, are not considered.(3)EN 1999 is intended to be used in conjunction with:-EN 1990 "Basis of structural design"-EN 1991 "Actions on structures"-European Standards construction products relevant for aluminium structures-EN 1090-1: Execution of steel structures and aluminium structures - Part 1: Requirements for conformity assessment of structural components -EN 1090-3: Execution of steel structures and aluminium structures - Part 3: Technical requirements for aluminium structures(4)EN 1999 is subdivided in five parts:EN 1999-1-1Design of Aluminium Structures: General structural rules.EN 1999-1-2Design of Aluminium Structures: Structural fire design.EN 1999-1-3Design of Aluminium Structures: Structures susceptible to fatigue.EN 1999-1-4Design of Aluminium Structures: Cold-formed structural sheeting.EN 1999-1-5Design of Aluminium Structures: Shell structures.1.1.2Scope of EN 1999-1-4(1)PEN 1999-1-4 gives design requirements for cold-formed trapezoidal aluminium sheeting. It applies to cold-formed aluminium products made from hot rolled or cold rolled sheet or strip that have been cold-formed by such processes as cold-rolled forming or press-breaking. The execution of aluminium structures made of cold-formed sheeting is covered in EN 1090-3.NOTEThe rules in this part complement the rules in other parts of EN 1999-1.(2)(...)

Committee
CEN/TC 250
DocumentType
Standard
PublisherName
Comite Europeen de Normalisation
Status
Withdrawn

Standards Relationship
UNE-EN 1999-1-4:2007 Identical

View more information
Sorry this product is not available in your region.

Access your standards online with a subscription

Features

  • Simple online access to standards, technical information and regulations.

  • Critical updates of standards and customisable alerts and notifications.

  • Multi-user online standards collection: secure, flexible and cost effective.

Need help?
Call us on 131 242, then click here to start a Screen Sharing session
so we can help right away! Learn more