Customer Support: 131 242

  • There are no items in your cart
We noticed you’re not on the correct regional site. Switch to our AMERICAS site for the best experience.
Dismiss alert

EN 50169:1994

Superseded

Superseded

A superseded Standard is one, which is fully replaced by another Standard, which is a new edition of the same Standard.

View Superseded by
superseded

A superseded Standard is one, which is fully replaced by another Standard, which is a new edition of the same Standard.

Sectional specification for backbone cables, riser and campus, with a common overall screen for use in digital communication

Superseded date

01-02-2001

Published date

07-10-1994

1. Guide to use
1.1 Scope
1.2 Introduction
1.3 Installation considerations
1.4 Object
2. Definitions and requirements
2.1 General
2.2 Reference publications
2.3 Definitions
2.4 Materials and cable construction
2.4.1 General
2.4.2 Cable construction
2.4.3 Conductor
2.4.4 Insulation
2.4.5 Cable element
2.4.6 Screening of the cable element
2.4.7 Colour code of insulation
2.4.8 Cable make-up
2.4.9 Screening of the cable core
2.4.10 Sheath
2.4.11 Colour of sheath
2.4.12 Identification
2.4.13 Finished cable
2.4.14 Cable overall diameter
3. Characteristics and requirements
3.1 General
3.2 Electrical tests
3.2.1 Conductor resistance
3.2.2 Resistance unbalance
3.2.3 Dielectric strength
3.2.4 Insulation resistance
3.2.5 Mutual capacitance
3.2.6 Capitance unbalance
3.2.7 Transfer impedance
3.3 Transmission characteristics
3.3.1 Velocity of propagation
3.3.2 Attenuation
3.3.3 Unbalance attenuation
3.3.4 Near-end crosstalk
3.3.5 Far-end crosstalk
3.3.6 Characteristics impedance
3.3.7 Structural Return Loss (SRL)
3.3.8 Longitudinal to Differential Conversion Loss (LCL)
3.4 Mechanical and dimension characteristics and
       requirements
3.4.1 Dimensional requirements
3.4.2 Elongation at break of conductors
3.4.3 Elongation and tensile strength at break of the
       insulation
3.4.4 Elongation and tensile strength at break of sheath
3.4.5 Crushing of the cable
3.4.6 Impact of the cable
3.4.7 Repeated bending of the cable
3.4.8 Tensile performance of the cable
3.5 Environmental characteristics
3.5.1 Shrinkage of insulation
3.5.2 Wrapping of insulation after thermal ageing
3.5.3 Bending of insulation at low temperature
3.5.4 Elongation and tensile strength at break of the
       sheath after ageing
3.5.5 Sheath pressure test at high temperature
3.5.6 Cold bend of the cable
3.5.7 Heat shock
3.5.9 Flame propagation characteristics of bunched cables
3.5.10 Acid gas evolution
3.5.11 Smoke generation
3.5.12 Toxic gas emission
4 Quality assessment procedures
Annex A (informative) Attenuation and NEXT.

This standard refers to HD 608 S1:1992, Generic specification for symmetrical pair/quad or multicore cables for digital communications. It covers individually screened or unscreened pair(s) or quad(s) in cables for vertical shafts or vertically between floors (riser backbone cables) or in horizontal between buildings (campus backbone cables). In the same cable both screened and unscreened elements may be used. When installed vertically extra strength requirements may be applicable and are defined in the detail specifications. The cables shall be provided with a common overall screen. These cables are suitable for different communication systems to which reference is made in the detail specifications. The cables covered by this specification are intended to operate with voltages and currents normally adopted for communication systems. These cables shall not be connected to low impedance sources, for example, the public mains electricity supply

Committee
CLC/TC 46X
DocumentType
Standard
PublisherName
European Committee for Standards - Electrical
Status
Superseded
SupersededBy

Standards Relationship
DIN EN 50169 : 1995 Identical
NEN EN 50169 : 1994 Identical
UNE-EN 50169:1996 Identical
NF EN 50169 : 1995 Identical
NBN EN 50169 : 1995 Identical
I.S. EN 50169:1995 Identical
VDE 0819-4 : 1995 Identical
BS EN 50169:1996 Identical
CEI EN 50169 : 1ED 1998 Identical
SN EN 50169 : 1994 Identical

DIN EN 50173:2000-07 INFORMATION TECHNOLOGY - GENERIC CABLING SYSTEMS

HD 606.1 : 200S1 MEASUREMENT OF SMOKE DENSITY OF ELECTRIC CABLES BURNING UNDER DEFINED CONDITIONS - TEST APPARATUS
HD 606.2 : 200S1 MEASUREMENT OF SMOKE DENSITY OF ELECTRIC CABLES BURNING UNDER DEFINED CONDITIONS - TEST PROCEDURE AND REQUIREMENTS
HD 624.5 : 200S1 MATERIALS USED IN COMMUNICATION CABLES - POLYPROPYLENE INSULATION COMPOUNDS
HD 624.7 : 200S1 MATERIALS USED IN COMMUNICATION CABLES - HALOGEN FREE FLAME RETARDANT THERMOPLASTIC SHEATHING COMPOUND
IEC TR 60344:2007 Calculation of d.c. resistance of plain and coated copper conductors of low-frequency cables and wires - Application guide
HD 624.4 : 200S1 MATERIALS USED IN COMMUNICATION CABLES - PE SHEATHING
HD 624.3 : S1 AMD 2 94 MATERIALS USED IN COMMUNICATION CABLES - PE SOLID INSULATION
HD 602 : 200S1 TEST ON GASES EVOLVED DURING COMBUSTION OF ELECTRIC CABLES - DETERMINATION OF DEGREE OF ACIDITY OF GASES EVOLVED DURING THE COMBUSTION OF MATERIALS TAKEN FROM ELECTRIC CABLES BY MEASURING PH CONDUCTIVITY
HD 624.6 : 200S1 MATERIALS USED IN COMMUNICATION CABLES - HALOGEN FREE FLAME RETARDANT INSULATION COMPOUNDS

View more information
Sorry this product is not available in your region.

Access your standards online with a subscription

Features

  • Simple online access to standards, technical information and regulations.

  • Critical updates of standards and customisable alerts and notifications.

  • Multi-user online standards collection: secure, flexible and cost effective.

Need help?
Call us on 131 242, then click here to start a Screen Sharing session
so we can help right away! Learn more