  • EN ISO 10993-7 : 2008 COR 2009

    Superseded A superseded Standard is one, which is fully replaced by another Standard, which is a new edition of the same Standard.
    Add to Watchlist
    This Standard has been added successfully to your Watchlist
    Please visit My Watchlist to see all standards that you are watching.
    Please log in or to add this standard to your Watchlist.
    We could not add this standard to your Watchlist.
    Please retry or contact support for assistance.
    We could not add this standard to your Watchlist.
    Please retry or contact support for assistance.
    You have already added this standard to your Watchlist.
    Visit My Watchlist to view the full list.

    BIOLOGICAL EVALUATION OF MEDICAL DEVICES - PART 7: ETHYLENE OXIDE STERILIZATION RESIDUALS (ISO 10993-7:2008/COR 1:2009)

    Available format(s): 

    Superseded date:  21-01-2022

    Language(s): 

    Published date:  15-11-2009

    Publisher:  Comite Europeen de Normalisation

    Add to Watchlist
    Pure ENs are not available for sale, please purchase a suitable national adoption

    Sorry this product is not available in your region.

    Add To Cart

    Table of Contents - (Show below) - (Hide below)

    Foreword
    Introduction
    1 Scope
    2 Normative references
    3 Terms and definitions
    4 Requirements
      4.1 General
      4.2 Categorization of devices
      4.3 Allowable limits
      4.4 Determination of EO and ECH residuals
    5 Product release
      5.1 General
      5.2 Release of products without dissipation curve data
      5.3 Procedure for product release using residue dissipation
          curves
    Annex A (normative) - Evaluation of gas chromatograms
    Annex B (informative) - Gas chromatographic determination
                            for EO and ECH
    Annex C (informative) - Flowchart and guidance for the
                            application of this part of ISO
                            10993 series of standards to the
                            determination of EO and ECH residuals
                            in medical devices
    Annex D (informative) - Factors influencing product residual
    Annex E (informative) - Extraction conditions for
                            determination of residual EO
    Annex F (informative) - Rationale for the provisions of this
                            part of ISO 10993
    Annex G (informative) - Establishment of allowable limits for
                            EO
    Annex H (informative) - Establishment of allowable limits for
                            ECH
    Annex I (informative) - Establishment of allowable limits for
                            EG
    Annex J (informative) - Preparation of EO and ECH standards
    Annex K (informative) - Ethylene oxide residue measuring
                            methods
    Bibliography
    Annex ZA (informative) - Relationship between this International
                             Standard and the Essential Requirements
                             of EU Directive 93/42/EEC Medical
                             devices
    Annex ZB (informative) - Relationship between this International
                             Standard and the Essential Requirements
                             of EU Directive 90/385/EEC on Active
                             Implantable Medical Devices

    Abstract - (Show below) - (Hide below)

    Describes allowable limits for residual ethylene oxide (EO) and ethylene chlorohydrin (ECH) in individual EO-sterilized medical devices, procedures for the measurement of EO and ECH, and methods for determining compliance so that devices may be released.

    General Product Information - (Show below) - (Hide below)

    Committee TC 206
    Document Type Standard
    Publisher Comite Europeen de Normalisation
    Status Superseded
    Superseded By
    Supersedes

    Standards Referenced By This Book - (Show below) - (Hide below)

    I.S. EN 12022:1999 BLOOD GAS EXCHANGERS
    I.S. EN 13503-8:2000 OPHTHALMIC IMPLANTS - INTRAOCULAR LENSES - PART 8: FUNDAMENTAL REQUIREMENTS
    DIN EN ISO 7199:2015-06 (Draft) CARDIOVASCULAR IMPLANTS AND ARTIFICIAL ORGANS - BLOOD-GAS EXCHANGERS (OXYGENATORS) (ISO 7199:2016)
    I.S. EN ISO 7198:2017 CARDIOVASCULAR IMPLANTS AND EXTRACORPOREAL SYSTEMS - VASCULAR PROSTHESES - TUBULAR VASCULAR GRAFTS AND VASCULAR PATCHES (ISO 7198:2016)
    UNE-EN ISO 7198:2017 Cardiovascular implants and extracorporeal systems - Vascular prostheses - Tubular vascular grafts and vascular patches (ISO 7198:2016)
    DIN EN 1422:2014-08 STERILIZERS FOR MEDICAL PURPOSES - ETHYLENE OXIDE STERILIZERS - REQUIREMENTS AND TEST METHODS
    BS EN 12006-2 : 1998 NON-ACTIVE SURGICAL IMPLANTS - PARTICULAR REQUIREMENTS FOR CARDIAC AND VASCULAR IMPLANTS - PART 2: VASCULAR PROSTHESES INCLUDING CARDIAC VALVE CONDUITS
    EN 12011 : 1998 INSTRUMENTATION TO BE USED IN ASSOCIATION WITH NON-ACTIVE SURGICAL IMPLANTS - GENERAL REQUIREMENTS
    EN 13503-8 : 2000 OPHTHALMIC IMPLANTS - INTRAOCULAR LENSES - PART 8: FUNDAMENTAL REQUIREMENTS
    EN 12022 : 1999 BLOOD GAS EXCHANGERS
    PREN 1422 : DRAFT 2011 STERILIZERS FOR MEDICAL PURPOSES - ETHYLENE OXIDE STERILIZERS - REQUIREMENTS AND TEST METHODS
    11/30252448 DC : 0 BS EN 1422 - STERILIZERS FOR MEDICAL PURPOSES - ETHYLENE OXIDE STERILIZERS - REQUIREMENTS AND TEST METHODS
    BS EN ISO 7199:2017 CARDIOVASCULAR IMPLANTS AND ARTIFICIAL ORGANS - BLOOD-GAS EXCHANGERS (OXYGENATORS) (ISO 7199:2016)
    I.S. EN 1422:2014 STERILIZERS FOR MEDICAL PURPOSES - ETHYLENE OXIDE STERILIZERS - REQUIREMENTS AND TEST METHODS
    DIN EN 1422:1997-11 STERILIZERS FOR MEDICAL PURPOSES - ETHYLENE OXIDE STERILIZERS - REQUIREMENTS AND TEST METHODS
    I.S. EN 12442-1:2000 ANIMAL TISSUES AND THEIR DERIVATIVES UTILIZED IN THE MANUFACTURE OF MEDICAL DEVICES - PART 1: ANALYSIS AND MANAGEMENT OF RISK
    DIN EN ISO 7199 E : 2017 CARDIOVASCULAR IMPLANTS AND ARTIFICIAL ORGANS - BLOOD-GAS EXCHANGERS (OXYGENATORS) (ISO 7199:2016)
    BS EN 12022:1999 BLOOD-GAS EXCHANGERS
    BS EN 12442-1:2000 ANIMAL TISSUES AND THEIR DERIVATIVES UTILIZED IN THE MANUFACTURE OF MEDICAL DEVICES - PART 1: ANALYSIS AND MANAGEMENT OF RISK
    I.S. EN 12006-2:1998 NON ACTIVE SURGICAL IMPLANTS - PARTICULAR REQUIREMENTS FOR CARDIAC AND VASCULAR IMPLANTS - PART 2: VASCULAR PROSTHESES INCLUDING CARDIAC VALVE CONDUITS
    UNI EN 12006-2 : 2009 NON ACTIVE SURGICAL IMPLANTS - PARTICULAR REQUIREMENTS FOR CARDIAC AND VASCULAR IMPLANTS - PART 2: VASCULAR PROSTHESES INCLUDING CARDIAC VALVE CONDUITS
    UNI EN 1422 : 2014 STERILIZERS FOR MEDICAL PURPOSES - ETHYLENE OXIDE STERILIZERS - REQUIREMENTS AND TEST METHODS
    BS EN ISO 25539-1:2017 Cardiovascular implants. Endovascular devices Endovascular prostheses
    I.S. EN 12011:1998 INSTRUMENTATION TO BE USED IN ASSOCIATION WITH NON-ACTIVE SURGICAL IMPLANTS - GENERAL REQUIREMENTS
    I.S. EN ISO 25539-1:2017 CARDIOVASCULAR IMPLANTS - ENDOVASCULAR DEVICES - PART 1: ENDOVASCULAR PROSTHESES (ISO 25539-1:2017)
    BS EN 13503-8:2000 OPHTHALMIC IMPLANTS - INTRAOCULAR LENSES - PART 8: FUNDAMENTAL REQUIREMENTS
    EN ISO 7198:2017 Cardiovascular implants and extracorporeal systems - Vascular prostheses - Tubular vascular grafts and vascular patches (ISO 7198:2016)
    EN 12006-2:1998+A1:2009 Non active surgical implants - Particular requirements for cardiac and vascular implants - Part 2: Vascular prostheses including cardiac valve conduits
    EN 1422:2014 Sterilizers for medical purposes - Ethylene oxide sterilizers - Requirements and test methods
    BS EN ISO 7198:2017 Cardiovascular implants and extracorporeal systems. Vascular prostheses. Tubular vascular grafts and vascular patches
    I.S. EN ISO 7199:2017 CARDIOVASCULAR IMPLANTS AND ARTIFICIAL ORGANS - BLOOD-GAS EXCHANGERS (OXYGENATORS) (ISO 7199:2016)
    DIN EN 12006-2:2009-08 NON ACTIVE SURGICAL IMPLANTS - PARTICULAR REQUIREMENTS FOR CARDIAC AND VASCULAR IMPLANTS - PART 2: VASCULAR PROSTHESES INCLUDING CARDIAC VALVE CONDUITS
    BS EN 1422:2014 STERILIZERS FOR MEDICAL PURPOSES - ETHYLENE OXIDE STERILIZERS - REQUIREMENTS AND TEST METHODS
    EN ISO 7199:2017 Cardiovascular implants and artificial organs - Blood-gas exchangers (oxygenators) (ISO 7199:2016)
    EN 12442-1 : 2000 ANIMAL TISSUES AND THEIR DERIVATIVES UTILIZED IN THE MANUFACTURE OF MEDICAL DEVICES - PART 1: ANALYSIS AND MANAGEMENT OF RISK

    Standards Referencing This Book - (Show below) - (Hide below)

    ISO 10993-3:2014 Biological evaluation of medical devices Part 3: Tests for genotoxicity, carcinogenicity and reproductive toxicity
    AAMI ST30 : 1989 DETERMINING RESIDUAL ETHYLENE CHLOROHYDRIN AND ETHYLENE GLYCOL IN MEDICAL DEVICES
    AAMI ST29 : 1988 DETERMINING RESIDUAL ETHYLENE OXIDE IN MEDICAL DEVICES
    ISO 11135-1:2007 Sterilization of health care products Ethylene oxide Part 1: Requirements for development, validation and routine control of a sterilization process for medical devices
    ISO 10993-10:2010 Biological evaluation of medical devices Part 10: Tests for irritation and skin sensitization
    AAMI ST43 : 3ED 93 GOOD HOSPITAL PRACTICE: ETHYLENE OXIDE GAS - VENTILATION RECOMMENDATIONS AND SAFE USE
    ISO 10993-12:2012 Biological evaluation of medical devices Part 12: Sample preparation and reference materials
    ISO 10993-17:2002 Biological evaluation of medical devices Part 17: Establishment of allowable limits for leachable substances
    ISO 10993-1:2009 Biological evaluation of medical devices Part 1: Evaluation and testing within a risk management process
    • Access your standards online with a subscription

      Features

      • Simple online access to standards, technical information and regulations
      • Critical updates of standards and customisable alerts and notifications
      • Multi - user online standards collection: secure, flexibile and cost effective
Need help?
Call us on 131 242, then click here to start a Screen Sharing session
so we can help right away! Learn more