Customer Support: 131 242

  • There are no items in your cart
We noticed you’re not on the correct regional site. Switch to our AMERICAS site for the best experience.
Dismiss alert

ENA TS 43-100 : ISSUE 1 1997

Superseded

Superseded

A superseded Standard is one, which is fully replaced by another Standard, which is a new edition of the same Standard.

View Superseded by
superseded

A superseded Standard is one, which is fully replaced by another Standard, which is a new edition of the same Standard.

CONDUCTOR TENSIONS AND SAGS

Superseded date

29-03-2015

Published date

12-01-2013

Foreword
1. Scope
2. References
3. Application
4. Metric Tension and Sag Charts
5. Conductor Erection
6. Sag Templates
7. Templates, Ranges and Errors
Appendix
A - Template Plotting Co-ordinates and Sag Template Ground
    Clearances and Support Heights
Figures
Fig.1 Tension and Sag Chart for 400 mm2 (54/7/3.18mm)
       ACSR Conductor
Fig.2 Tension and Sag Chart for 175mm2 (30/7/2.79mm)
       ACSR Conductor
Fig.3 Tension and Sag Chart for 70mm (12/7/2.79mm)
       ACSR Conductor
Fig.4 Sag Template Outline: 400mm2 ACSR
Fig.5 Sag Template Outline: 175mm2 ACSR
Fig.6 Sag Template Errors: 400mm2 ACSR
Fig.7 Sag Template Errors 175mm2

Gives the metric tension and sag charts for 400mm2, 175mm2 and 70mm2 ACSR line and earth conductors and states requirements for erecting. Also gives, construction details of the associated sag plotting templates for lines that are suitable for 75 Deg C maximum conductor temperature and these are included together with template error charts.

DocumentType
Standard
PublisherName
Energy Networks Association (UK)
Status
Superseded
SupersededBy

ESI 43-6 : ISSUE 2 CONSTRUCTION OF OVERHEAD TRANSMISSION LINES ON STEEL TOWERS FOR 132kV AND HIGHER VOLTAGES
ESI 43-4 : ISSUE 2 AMD 1 DESIGN OF FOUNDATIONS FOR STEEL TOWERS FOR OVERHEAD TRANSMISSION LINES AT 132kV AND HIGHER VOLTAGES
ESI 43-1 : ISSUE 2 AMD 1 SURVEY AND PREPARATION OF GROUND LINE PROFILES AND PLOTTING OF TOWER POSITIONS FOR STEEL TOWER OVERHEAD TRANSMISSION LINES AT 132kV AND HIGHER VOLTAGES
ESI 43-2 : ISSUE 1 DESIGN OF STEEL TOWER OVERHEAD TRANSMISSION LINES AT 132kV AND HIGHER VOLTAGES
ESI 43-3 : ISSUE 1 DESIGN OF LATTICE STEEL TRANSMISSION TOWERS FOR OVERHEAD LINES AT 132kV AND HIGHER VOLTAGES

View more information
Sorry this product is not available in your region.

Access your standards online with a subscription

Features

  • Simple online access to standards, technical information and regulations.

  • Critical updates of standards and customisable alerts and notifications.

  • Multi-user online standards collection: secure, flexible and cost effective.

Need help?
Call us on 131 242, then click here to start a Screen Sharing session
so we can help right away! Learn more