FOREWORD
1 Scope and object
2 Normative references
3 Preparation
4 Test method
5 Details to be specified
Annex A (informative) - Typical circuit diagram
IEC 60512-9-3:2011 defines a standard test method to assess the mechanical and electrical operational endurance, i.e. engaging and separating cycles, of a connector in an operating mode which includes a specified electrical load. This second edition cancels and replaces Test 9c of IEC 60512-5, issued in 1992, and constitutes a technical revision. The main technical changes with regard to the previous edition are as follows:
- An additional requirement to 4.1 stating that if more than one electrical circuit is wired for testing, the wiring shall be carried out in a parallel electrical circuit.
- Subclauses 4.3 through 4.7 were removed and replaced by 4.2 through 4.4.
This publication is to be read in conjunction with IEC 60512-1:2001 and IEC 60512-1-100:2006.
Committee |
TC 48/SC 48B
|
DevelopmentNote |
To be read in conjunction with IEC 60512-1 and IEC 60512-1-100. (02/2006) Stability Date: 2017. (10/2012)
|
DocumentType |
Standard
|
Pages |
17
|
PublisherName |
International Electrotechnical Committee
|
Status |
Current
|
Supersedes |
Standards | Relationship |
NBN EN 60512-9-3 : 2011 | Identical |
NEN EN IEC 60512-9-3 : 2011 | Identical |
PN EN 60512-9-3 : 2011 | Identical |
VDE 0687-512-9-3 : 2012 | Identical |
DIN EN 60512-9-3 : 2012 | Identical |
BS EN 60512-9-3:2011 | Identical |
CEI EN 60512-9-3 : 2012 | Identical |
EN 60512-9-3:2011 | Identical |
UNE-EN 60512-9-3:2011 | Identical |
I.S. EN 60512-9-3:2011 | Identical |
UNE-EN 60512-9-3:2006 | Identical |
SN EN 60512-9-3 : 2006 | Identical |
NF EN 60512-9-3 : 2012 | Identical |
CEI EN 60512-99-001 : 2013 | CONNECTORS FOR ELECTRONIC EQUIPMENT - TESTS AND MEASUREMENTS - PART 99-001: TEST SCHEDULE FOR ENGAGING AND SEPARATING CONNECTORS UNDER ELECTRICAL LOAD - TEST 99A: CONNECTORS USED IN TWISTED PAIR COMMUNICATION CABLING WITH REMOTE POWER |
PD CLC/TR 50174-99-1:2015 | Information technology. Cabling installation Remote powering |
15/30327728 DC : 0 | BS EN 60512-99-002 - CONNECTORS FOR ELECTRONIC EQUIPMENT - TESTS AND MEASUREMENTS - PART 99-002: ENDURANCE TEST SCHEDULES - TEST 99B: TEST SCHEDULE FOR ENGAGING AND SEPARATING CONNECTORS UNDER ELECTRICAL LOAD CONNECTORS |
17/30334978 DC : 0 | BS EN 62946-01 ED 1.0 - CONNECTORS FOR ELECTRONIC EQUIPMENT - PART 01: RECTANGULAR CONNECTORS - DETAIL SPECIFICATION FOR 8-WAY, SHIELDED, FREE AND FIXED HIGH DENSITY CONNECTORS FOR DATA TRANSMISSION WITH FREQUENCIES UP TO 100 MHZ AND WITH CURRENT CARRING CAPACITY UP TO 1A |
17/30361901 DC : 0 | BS EN 61076-3-125 - CONNECTORS FOR ELECTRONIC EQUIPMENT - PRODUCT REQUIREMENTS - DETAIL SPECIFICATION FOR 2-WAY, SHIELDED AND UNSHIELDED, FREE AND FIXED CONNECTORS FOR DATA TRANSMISSION UP TO 600 MHZ WITH CURRENT CARRYING CAPACITY |
S.R. CLC/TR 50174-99-1:2015 | INFORMATION TECHNOLOGY - CABLING INSTALLATION - PART 99-1: REMOTE POWERING |
IEC 62946-01:2018 | Connectors for electrical and electronic equipment - Part 01: Rectangular connectors - Detail specification for 8-way, shielded, free and fixed high density connectors for data transmission with frequencies up to 100 MHz and with current carring capacity up to 1A |
BS EN 60512-99-001:2012 | Connectors for electronic equipment. Tests and measurements Test schedule for engaging and separating connectors under electrical load. Test 99a: Connectors used in twisted pair communication cabling with remote power |
09/30197932 DC : 0 | BS EN 60512-99-001 - CONNECTORS FOR ELECTRONIC EQUIPMENT - TESTS AND MEASUREMENTS - PART 99-001: TEST SCHEDULE FOR MATING AND UN-MATING CONNECTORS UNDER ELECTRICAL LOAD - POWER OVER THE INTERNET (PLUS) POEP, PARTICULARLY APPLICABLE TO IEC 60603-7 SERIES CONNECTORS |
NF EN 60512-99-001 : 2013 | CONNECTORS FOR ELECTRONIC EQUIPMENT - TESTS AND MEASUREMENTS - PART 99-001: TEST SCHEDULE FOR ENGAGING AND SEPARATING CONNECTORS UNDER ELECTRICAL LOAD - TEST 99A: CONNECTORS USED IN TWISTED PAIR COMMUNICATION CABLING WITH REMOTE POWER |
IEC 60512-99-001:2012 | Connectors for electronic equipment - Tests and measurements - Part 99-001: Test schedule for engaging and separating connectors under electrical load - Test 99a: Connectors used in twisted pair communication cabling with remote power |
I.S. EN 60512-99-001:2012 | CONNECTORS FOR ELECTRONIC EQUIPMENT - TESTS AND MEASUREMENTS - PART 99-001: TEST SCHEDULE FOR ENGAGING AND SEPARATING CONNECTORS UNDER ELECTRICAL LOAD - TEST 99A: CONNECTORS USED IN TWISTED PAIR COMMUNICATION CABLING WITH REMOTE POWER (IEC 60512-99-001:2012 (EQV)) |
CLC/TR 50174-99-1:2015 | Information technology - Cabling installation - Part 99-1: Remote powering |
IEC TR 62652:2010 | Effects of engaging and separating under electrical load on connector interfaces in cabling used to support IEEE 802.3af (power-over-ethernet) applications |
EN 60512-99-001:2012 | Connectors for electronic equipment - Tests and measurements - Part 99-001: Test schedule for engaging and separating connectors under electrical load - Test 99a: Connectors used in twisted pair communication cabling with remote power |
IEC 60512-3-1:2002 | Connectors for electronic equipment - Tests and measurements - Part 3-1: Insulation tests - Test 3a: Insulation resistance |
IEC 60068-1:2013 | Environmental testing - Part 1: General and guidance |
IEC 60068-2-13:1983 | Basic environmental testing procedures - Part 2-13: Tests - Test M: Low air pressure |
IEC 60512-2-2:2003 | Connectors for electronic equipment - Tests and measurements - Part 2-2: Electrical continuity and contact resistance tests - Test 2b: Contact resistance - Specified test current method |
IEC 60512-1-1:2002 | Connectors for electronic equipment - Tests and measurements - Part 1-1: General examination - Test 1a: Visual examination |
IEC 60512-1-100:2012 | Connectors for electronic equipment - Tests and measurements - Part 1-100: General - Applicable publications |
IEC 60512-2-1:2002 | Connectors for electronic equipment - Tests and measurements - Part 2-1: Electrical continuity and contact resistance tests - Test 2a: Contact resistance - Millivolt level method |
IEC 60512-4-1:2003 | Connectors for electronic equipment - Tests and measurements - Part 4-1: Voltage stress tests - Test 4a: Voltage proof |
IEC 60512-1:2001 | Connectors for electronic equipment - Tests and measurements - Part 1: General |
Please Login or Create an Account so you can add users to your Multi user PDF Later.
Important note : All end users must be registered with an Account prior to user licenses being assigned.
Users cannot be edited or removed once added to your Multi user PDF.
Access your standards online with a subscription
Features
-
Simple online access to standards, technical information and regulations.
-
Critical updates of standards and customisable alerts and notifications.
-
Multi-user online standards collection: secure, flexible and cost effective.