Customer Support: 131 242

  • There are no items in your cart
We noticed you’re not on the correct regional site. Switch to our AMERICAS site for the best experience.
Dismiss alert

ISO/ASTM 51401:2002

Withdrawn

Withdrawn

A Withdrawn Standard is one, which is removed from sale, and its unique number can no longer be used. The Standard can be withdrawn and not replaced, or it can be withdrawn and replaced by a Standard with a different number.

View Superseded by
withdrawn

A Withdrawn Standard is one, which is removed from sale, and its unique number can no longer be used. The Standard can be withdrawn and not replaced, or it can be withdrawn and replaced by a Standard with a different number.

Practice for use of a dichromate dosimetry system

Available format(s)

Hardcopy , PDF 1 User , PDF 3 Users , PDF 5 Users , PDF 9 Users

Withdrawn date

18-03-2019

Language(s)

English

Published date

18-04-2002

ISO/ASTM 51401 covers the preparation, testing, and procedure for using the acidic aqueous silver dichromate dosimetry system to measure absorbed doses in water when exposed to ionizing radiation. The system consists of a dosimeter and appropriate analytical instrumentation. For simplicity, the system is referred to as the dichromate system and is classified as a reference standard dosimetry system.

This International Standard describes the spectrophotometric analysis procedures for the dichromate system.

It applies only to gamma-rays, X-rays and high energy electrons provided the following conditions are satisfied:

the absorbed dose range is from 2 times 103 Gy to 5 times 10 4 Gy;

the absorbed dose rate does not exceed 600 Gy/pulse with a pulse repetition rate not exceeding 12,5 Hz, or does not exceed an equivalent dose rate of 7,5 kGy/s from continuous sources;

for radionuclide gamma-ray sources, the initial photon energy is greater than 0,6 MeV;

for bremsstrahlung photons, the initial energy of the electrons used to produce the bremsstrahlung photons is equal to or greater than 2 MeV

for electron beams, the initial electron energy is greater than 8 MeV;

the irradiation temperature of the dosimeter is above 0 C and below 80 C.

DocumentType
Standard
Pages
7
PublisherName
International Organization for Standardization
Status
Withdrawn
SupersededBy
Supersedes

View more information
$118.72
Including GST where applicable

Access your standards online with a subscription

Features

  • Simple online access to standards, technical information and regulations.

  • Critical updates of standards and customisable alerts and notifications.

  • Multi-user online standards collection: secure, flexible and cost effective.

Need help?
Call us on 131 242, then click here to start a Screen Sharing session
so we can help right away! Learn more