Customer Support: 131 242

  • There are no items in your cart
We noticed you’re not on the correct regional site. Switch to our AMERICAS site for the best experience.
Dismiss alert

NEMA ICS 61800-1:2002(R2007)

Current

Current

The latest, up-to-date edition.

Adjustable Speed Electrical Power Drive Systems, Part 1: General Requirements—Rating Specifications for Low Voltage Adjustable-Speed DC Power Drive Systems

Published date

23-04-2002

Foreword
1 GENERAL
  1.1 Scope and Object
  1.2 Normative References
  1.3 Symbols
2 DEFINITIONS
  2.1 System
      2.1.1 d.c. Power Drive System (PDS)
      2.1.2 d.c. Power Drive System-Hardware Configuration
  2.2 Converters
      2.2.1 Converter, General Purpose
      2.2.2 Rectifying - Rectification
      2.2.3 Inverting - Inversion
      2.2.4 Converter, d.c. Linked
      2.2.5 Converter, Line-Side Commulated
      2.2.6 Chopper
      2.2.7 Converter, Voltage Source
      2.2.8 Converter, Voltage Source
  2.3 Drive System Operating Characteristics
      2.3.1 Two Quadrant Operation
      2.3.2 Four Quadrant Operation
      2.3.3 Dynamic Braking
      2.3.4 Regeneration
  2.4 CDM, BDM and Converter Input Parameters
      2.4.1 Rated System Voltage U[LN]
      2.4.2 Rated System Frequency f[LN]
      2.4.3 Line-Side Rated a.c. Voltage U[VN]
      2.4.4 Void
      2.4.5 Rated Input Current
      2.4.6 Line-Side Harmonic Content
      2.4.7 Characteristic Current Harmonics
      2.4.8 Harmonic Distortion
      2.4.9 Converter Input Displacement Factor cos[phi][V1]
      2.4.10 Line-Side Displacement Factor cos[phi][V1]
      2.4.11 Input Total Power Factor, lambda[L]
      2.4.12 Maximum a.c. System, Symmetrical Short-Circuit
             Current ISCM
  2.5 CDM, BDM and Converter Output Parameters
      2.5.1 d.c. current l[d]
      2.5.2 Rated Continuous Output Current l[dN]
      2.5.3 Overload Capacity l[dM]
      2.5.4 Continuous Output Rating P[dN]
      2.5.5 Rated Output Voltage U[dN]
      2.5.6 Ripple U[pp], l[pp]
      2.5.7 Load-Side Harmonic Content
      2.5.8 Efficiency of Power Conversion eta[D], eta[C]
      2.5.9 Maximum Field Supply current l[FM]
      2.5.10 Rated Field Supply Voltage U[FN]
  2.6 Converter Circuitry and circuit Elements
      2.6.1 Commutating Capacitor
      2.6.2 Commutating Inductor
      2.6.3 a.c. Filter Network
      2.6.4 Power Factor Correction Network
      2.6.5 d.c. Filter Capacitor
  2.7 Motors
      2.7.1 d.c. Motors Types
      2.7.2 Rated Hot Field Voltage
      2.7.3 Base Speed N[0]
      2.7.4 Maximum Safe Motor Speed
      2.7.5 Torque Pulsation
  2.8 Control Systems
      2.8.1 Controlled Variable
      2.8.2 Service Variable
      2.8.3 Operating Variable
      2.8.4 Feedback Control System Variables
3 FUNDAMENTAL FEATURES
  3.1 Operational
  3.2 Fault Supervision
  3.3 Minimum Status Indication Required
  3.4 I/O Devices
4 SERVICE CONDITIONS
  4.1 Installation and Operation
      4.1.1 Electrical Service Conditions
      4.1.2 Environmental Service Conditions
      4.1.3 Unusual Environmental Service Conditions
      4.1.4 Installation, Compressing and Operation
  4.2 Storage of Equipment
      4.2.1 Climatic Conditions
      4.2.2 Specific Storage Hazards
  4.3 Transportation
      4.3.1 Climatic Conditions
      4.3.2 Unusual Climatic Conditions
      4.3.3 Mechanical Conditions
5 RATINGS
  5.1 BDM Input Ratings
      5.1.1 Input Voltages
      5.1.2 Input Currents
  5.2 BDM Output Ratings
      5.2.1 Continuous Output Ratings
      5.2.2 Overload Capacity
      5.2.3 Speed Range
      5.2.4 Existing d.c. Voltage Ratings
  5.3 Efficiency and Losses
  5.4 Ripple
  5.5 Transformers and Reactors
6 PERFORMANCE REQUIREMENTS
  6.1 Steady-state Performance
      6.1.1 Deviation Band
      6.1.2 Selection of Deviation Bands (Steady-State)
      6.1.3 Service Deviation Band-Limits
      6.1.4 Operating Deviation Band-Limits
      6.1.5 Resolution
  6.2 Dynamic Performance
  6.3 Dynamic Braking and Dynamic Slowdown
      6.3.1 Dynamic Braking
      6.3.2 Dynamic Slowdown
  6.4 Other Performance Requirements
      6.4.1 Use of the Drive in the Application
      6.4.2 Use of the Drive in its Connection to Supply
      6.4.3 Ratings
      6.4.4 Protective Devices
7 Tests
  7.1 Classification of Tests
      7.1.1 Types Test
      7.1.2 Routine Test
      7.1.3 Sampling Test
      7.1.4 Special Test
      7.1.5 Workshop Test
      7.1.6 Acceptance Test
      7.1.7 Commissioning Test
      7.1.8 Witness Test
  7.2 Performance of Tests
      7.2.1 General Conditions
      7.2.2 Earthing Conditions
  7.3 Items of Separate Device Tests
      7.3.1 Standard Tests for PDS
      7.3.2 Standard Tests for CDM/BDM
      7.3.3 Checking the Properties of the Equipment of
             CDM/BDM
  7.4 Items of Power Drive Systems Tests
      7.4.1 Test Set-Up
      7.4.2 Definitions of Rating Tests
      7.4.3 Definitions of Dynamic Tests
8 PRODUCT INFORMATION
  8.1 Marking
  8.2 Information to be Supplied With the PDS or CDM/BDM
      8.2.1 Information to be Supplied With the Furnished
             Equipment
      8.2.2 Information to be Supplied or Made Available
      8.2.3 Speed Information to Be Supplied With the Power
             Drive System
9 SAFETY AND WARNING LABELS
  9.1 Warning Labels
  9.2 Safety and Nature of a PDS
Annexes
Annex A - MOTOR CONSIDERATIONS
Annex B - LINE-SIDE CONSIDERATIONS
Annex C - AUXILIARY EQUIPMENT
Annex D - CONTROL STRATEGIES
Annex E - TOPOLOGIES
Annex G - MONITORING FEATURES

Applies to general purpose adjustable speed dc drive systems that include the power conversion, control equipment and a motor or motors.

DocumentType
Standard
PublisherName
National Electrical Manufacturers Association
Status
Current
Supersedes

NEMA ICS 7 : 2014 INDUSTRIAL CONTROL AND SYSTEMS: ADJUSTABLE - SPEED DRIVES
NEMA ICS 20:2009 (R2015) Informational Guide to Electrical Industrial Topics
NEMA ICS 61800-2:2005 Adjustable Speed Electrical Power Drive Systems, Part 2: General Requirements—Rating Specifications for Low Voltage Adjustable Frequency AC Power Drive Systems
NEMA ICS 3.1 : 2009(R2014) GUIDE FOR THE APPLICATION, HANDLING, STORAGE, INSTALLATION, AND MAINTENANCE OF MEDIUM-VOLTAGE AC CONTACTORS, CONTROLLERS, AND CONTROL CENTERS
NEMA ICS 61800-4-2004 ADJUSTABLE SPEED ELECTRICAL POWER DRIVE SYSTEMS - PART 4: GENERAL REQUIREMENTS - RATING SPECIFICATIONS FOR A.C. POWER DRIVE SYSTEMS ABOVE 1000 V A.C. AND NOT EXCEEDING 35 KV

IEEE 519-2014 REDLINE IEEE Recommended Practice and Requirements for Harmonic Control in Electric Power Systems
NEMA MG 1 : 2016 MOTORS AND GENERATORS
NEMA ICS 1.3:1986 (R2001, R2009, R2015) Preventive Maintenance of Industrial Control and Systems Equipment
NEMA ICS 7.1:2014 Safety Standards for Construction and Guide for Selection, Installation and Operation of Adjustable Speed Drive Systems
NEMA 250 : 2014 ENCLOSURES FOR ELECTRICAL EQUIPMENT (1000 VOLTS MAXIMUM)
NEMA ICS 6-1993 (R2006) Industrial Control and Systems: Enclosures
NFPA 70 : 2017 NATIONAL ELECTRICAL CODE
NEMA ICS 1 : 2000(R2015) INDUSTRIAL CONTROL AND SYSTEMS: GENERAL REQUIREMENTS

View more information
Sorry this product is not available in your region.

Access your standards online with a subscription

Features

  • Simple online access to standards, technical information and regulations.

  • Critical updates of standards and customisable alerts and notifications.

  • Multi-user online standards collection: secure, flexible and cost effective.

Need help?
Call us on 131 242, then click here to start a Screen Sharing session
so we can help right away! Learn more