Customer Support: 131 242

  • There are no items in your cart
We noticed you’re not on the correct regional site. Switch to our AMERICAS site for the best experience.
Dismiss alert

NF EN 54-7 : 2001 AMD 2 2006

Superseded

Superseded

A superseded Standard is one, which is fully replaced by another Standard, which is a new edition of the same Standard.

View Superseded by
superseded

A superseded Standard is one, which is fully replaced by another Standard, which is a new edition of the same Standard.

FIRE DETECTION AND FIRE ALARM SYSTEMS - PART 7: SMOKE DETECTORS - POINT DETECTORS USING SCATTERED LIGHT, TRANSMITTED LIGHT OR IONIZATION

Superseded date

25-07-2019

Published date

12-01-2013

Avant-propos
1 Domaine d'application
2 Références normatives
3 Termes et définitions
4 Exigences
  4.1 Conformité
  4.2 Indication individuelle d'alarme
  4.3 Raccordement de dispositifs auxiliaires
  4.4 Surveillance des détecteurs à tête amovible
  4.5 Moyens de calibrage
  4.6 Réglage sur site de la sensibilité de fonctionnement
  4.7 Protection contre la pénétration de corps étrangers
  4.8 Réponse aux foyers à évolution lente
  4.9 Marquage
  4.10 Documentation
  4.11 Exigences complémentaires pour les détecteurs utilisant un
       logiciel
5 Essais
  5.1 Généralités
  5.2 Reproductibilité
  5.3 Influence de la direction
  5.4 Dispersion d'exemplaires
  5.5 Variation des paramètres d'alimentation électrique
  5.6 Influence des courants d'air
  5.7 Influence de la lumière artificielle
  5.8 Chaleur sèche (Essai fonctionnel)
  5.9 Froid (Essai fonctionnel)
  5.10 Chaleur humide continue (Essai fonctionnel)
  5.11 Chaleur humide continue (Essai d'endurance)
  5.12 Corrosion par le dioxyde de soufre (SO2) (Essai d'endurance)
  5.13 Choc (Essai fonctionnel)
  5.14 Impact (Essai fonctionnel)
  5.15 Vibration sinusoïdale (Essai fonctionnel)
  5.16 Vibration sinusoïdale (Essai d'endurance)
  5.17 Compatibilité électromagnétique (CEM), essais d'immunité (Essai
       fonctionnel)
  5.18 Sensibilité sur foyers types
Annexe A (normative) Tunnel de fumée pour les mesures du seuil de
                       réponse
Annexe B (normative) Produit d'aérosol d'essai pour la mesure des
                       valeurs du seuil de réponse
Annexe C (normative) Instruments de mesure de la fumée
Annexe D (normative) Appareil d'essai d'éclats
Annexe E (informative) Appareil pour l'essai d'impact
Annexe F (normative) Local d'essai feu
Annexe G (normative) TF2 - Feu de bois à combustion lente (pyrolyse)
Annexe H (normative) TF3 - Feu de coton à combustion lente
Annexe I (normative) TF4 - Feu de matières plastiques inflammables
                       (polyuréthanne)
Annexe J (normative) TF5 - Feu de liquide inflammable (n-heptane)
Annexe K (informative) Information relative à la construction du tunnel
                       de fumée
Annexe L (informative) Information relative aux exigences de la réponse
                       aux feux à développement lent
Annexe M (informative) Information relative à la construction de la
                       chambre de mesure d'ionisation

Deals in requirements, test methods and performance criteria for point smoke detectors that operate using scattered light, transmitted light or ionization, for use in fire detection and fire alarm systems for buildings.

DevelopmentNote
Indice de Classement: S61-987PR. Supersedes NFS 61 954 and NFS 61 956. (05/2001) PR NF EN 54-7 May 2011. (05/2011)
DocumentType
Standard
PublisherName
Association Francaise de Normalisation
Status
Superseded
SupersededBy
Supersedes

NFS 61 961 : 2007 FIRE DETECTION EQUIPMENT - ACTUATING DETECTOR SYSTEMS
NFS 61 023 : 2004 XP FIRE DETECTION SYSTEMS (FDS) USING RADIO LINKS

ISO 209-1:1989 Wrought aluminium and aluminium alloys Chemical composition and forms of products Part 1: Chemical composition
NF EN 54-1 : 2011 FIRE DETECTION AND FIRE ALARM SYSTEMS - PART 1: INTRODUCTION
IEC 60068-1:2013 Environmental testing - Part 1: General and guidance
IEC 60068-2-27:2008 Environmental testing - Part 2-27: Tests - Test Ea and guidance: Shock
IEC 60068-2-3:1969 Basic environmental testing procedures - Part 2-3: Tests - Test Ca: Damp heat, steady state
NF EN 60068-2-1 : 2007 ENVIRONMENTAL TESTING - PART 2-1: TESTS - TESTS A: COLD
NF EN 60068-1 : 2014 ENVIRONMENTAL TESTING - PART 1: GENERAL AND GUIDANCE
NF EN 50130-4 : 2014 AMD 1 2014 ALARM SYSTEMS - PART 4: ELECTROMAGNETIC COMPATIBILITY - PRODUCT FAMILY STANDARD: IMMUNITY REQUIREMENTS FOR COMPONENTS OF FIRE, INTRUDER, HOLD UP, CCTV, ACCESS CONTROL AND SOCIAL ALARM SYSTEMS
NF EN 60068 2-6 : 2008 ENVIRONMENTAL TESTING - PART 2-6: TESTS - TEST FC: VIBRATION (SINUSOIDAL)
NF EN 60068 2-27 : 2009 ENVIRONMENTAL TESTING - PART 2-27: TESTS - TEST EA AND GUIDANCE: SHOCK
IEC 60068-2-42:2003 Environmental testing - Part 2-42: Tests - Test Kc: Sulphur dioxide test for contacts and connections
IEC 60068-2-1:2007 Environmental testing - Part 2-1: Tests - Test A: Cold
IEC 60068-2-56:1988 Environmental testing - Part 2: Tests. Test Cb: Damp heat, steady state, primarily for equipment

View more information
Sorry this product is not available in your region.

Access your standards online with a subscription

Features

  • Simple online access to standards, technical information and regulations.

  • Critical updates of standards and customisable alerts and notifications.

  • Multi-user online standards collection: secure, flexible and cost effective.

Need help?
Call us on 131 242, then click here to start a Screen Sharing session
so we can help right away! Learn more