Customer Support: 131 242

  • There are no items in your cart
We noticed you’re not on the correct regional site. Switch to our AMERICAS site for the best experience.
Dismiss alert

NFC 32 332 : 2002

Current

Current

The latest, up-to-date edition.

INSULATED CABLES AND FLEXIBLE CORDS FOR INSTALLATIONS - CABLES FOR SUPPLY LEADS WITH METALLIC COVERING FOR HEATING EQUIPMENT BY MEANS OF HEATING CABLES, WITH METALLIC COVERING, FOR EMBEDDING IN WALLS OF BUILDING

Published date

12-01-2013

AVANT-PROPOS
1 DOMAINE D'APPLICATION
2 RÉFÉRENCES NORMATIVES
3 DÉFINITIONS
4 DÉSIGNATION
5 REPÉRAGE DES CONDUCTEURS DES LIAISONS FROIDES
6 CONSTITUTION
7 TEMPÉRATURE SPÉCIFIÉE DES CABLES
8 RIGIDITÉ DIÉLECTRIQUE
9 RÉSISTANCE MÉCANIQUE
10 COMPATIBILITÉ DES CONSTITUANTS
11 GÉNÉRALITÉS SUR LES ESSAIS
12 RÉSISTANCE LINÉIQUE
13 VÉRIFICATION DE LA RÉSISTANCE D'ISOLEMENT
14 VÉRIFICATION DE LA RIGIDITÉ DIÉLECTRIQUE
15 ESSAI DE TRACTION
16 ESSAI DE COMPRESSION DES CABLES
17 ESSAI D'ENROULEMENTS ALTERNÉS
18 ESSAI DE PÉNÉTRATION A TRAVERS LE REVETEMENT MÉTALLIQUE
19 CARACTÉRISTIQUES DES LIAISONS FROIDES
20 RÉSISTANCE A L'HUMIDITÉ
21 RÉSISTANCE MÉCANIQUE
22 ISOLEMENT ÉLECTRIQUE
Annexe A (informative) - RACCORDEMENT INTERMÉDIAIRE ENTRE LES
                         ÉLÉMENTS CHAUFFANTS MONTÉS EN SÉRIE

La présente norme s'applique aux câbles de liaisons froides à isolation synthétique, comportant un revêtement métallique, destinés à raccorder des équipements de chauffage électrique réalisés à partir des câbles chauffants monoconducteurs revêtus d'un revêtement métallique, conformes à la norme NFC 32 330, de tension nominale 500 V et destinés à être incorporés dans les parois des bâtiments. Les normes d'installation NFC 15 100 et UTEC 15 720 fixent les règles de sécurité électrique à respecter pour la réalisation d'équipement de chauffage électrique. Il convient de préciser les règles de construction des câbles de liaisons froides en prenant en compte la nouveauté et la diversité des produits apparus sur le marché depuis la parution de ces normes, et permettre l'usage de câbles spécifiquement adaptés à cette fonction. La présente norme s'applique aux câbles suivants: - câbles isolés en matière organique, avec revêtement métallique n'assurant pas une protection mécanique; - câbles isolés en matière organique, avec revêtement métallique assurant une protection mécanique. Note: les liaisons froides réalisées en câbles à isolant minéral et pouvant se raccorder aux câbles chauffants à isolant minéral ne sont pas décrits dans cette norme. Du point de vue comportement au feu, le câble décrit par cette norme est de catégorie C2 selon la norme NFC 32 070. Indiquée par le constructeur, la température maximale de l'âme en fonctionnement ne doit pas dépasser celle indiquée dans cette norme. Cette norme a pour but de normaliser des câbles qui soient sûrs et fiables lorsqu'ils sont correctement utilisés, de définir les prescriptions relatives à la fabrication ainsi que les caractéristiques se rapportant à la sécurité et de préciser les méthodes pour la vérification de la conformité à ces dispositions.

DevelopmentNote
Indice de Classement: C32-332 (03/2002)
DocumentType
Standard
PublisherName
Association Francaise de Normalisation
Status
Current

NFC 32 330 : 2002 INSULATED CABLES AND CORDS FOR INSTALLATIONS AND EQUIPMENT - HEATING EQUIPMENT BY MEANS OF HEATING CABLES FOR EMBEDDING INTO WALLS OF BUILDINGS

NFC 32 090 : 84 AMD 2 93 INSULATED CABLES AND FLEXIBLE CORDS FOR ELECTRIC POWER AND LIGHTING - EXTRUDED SOLID DIELECTRIC INSULATED CABLES OF RATED VOLTAGE UP TO AND INCLUDING 600/1 000 V
NFC 32 102-1 : 2003 CABLES OF RATED VOLTAGES UP TO AND INCLUDING 450/750 V AND HAVING CROSS-LINKED INSULATION - PART 1: GENERAL REQUIREMENTS
NF EN 50102 : 95 AMD 1 99 DEGRES DE PROTECTION PROCURES PAR LES ENVELOPPES DE MATERIELS ELECTRIQUES CONTRE LES IMPACTS MECANIQUES EXTERNES (CODE IK)
NF EN 60811 3-2 : 1996 AMD 2 2004 INSULATING AND SHEATHING MATERIALS OF ELECTRIC CABLES - COMMON TEST METHODS - PART 3: METHODS SPECIFIC TO PVC COMPOUNDS - SECTION 2: LOSS OF MASS TEST - THERMAL STABILITY TEST
NFC 32 050 : 1990 INSULATED CABLES AND FLEXIBLE CORDS FOR INSTALLATIONS - METAL SHEATHED CABLES - RULES
NF EN 60811 1-3 : 96 AMD 1 2001 INSULATING AND SHEATHING MATERIALS OF ELECTRIC CABLES - COMMON TEST METHODS - PART 1: GENERAL APPLICATION - SECTION 3: METHODS FOR DETERMINING THE DENSITY - WATER ABSORPTION TESTS - SHRINKAGE TEST
NFC 30 204 : 88 AMD 1 1991 INSULATED CABLES AND FLEXIBLE CORDS - MARKING OF CABLES
NFC 32 201-1 : 2003 CABLES OF RATED VOLTAGES UP TO AND INCLUDING 450/750 V AND HAVING THERMOPLASTIC INSULATION - PART 1: GENERAL REQUIREMENTS
NFC 01 461 : 2008 INTERNATIONAL ELECTROTECHNICAL VOCABULARY - PART 461: ELECTRIC CABLES
NFC 32 330 : 2002 INSULATED CABLES AND CORDS FOR INSTALLATIONS AND EQUIPMENT - HEATING EQUIPMENT BY MEANS OF HEATING CABLES FOR EMBEDDING INTO WALLS OF BUILDINGS
NFC 32 013 : 1981 INSULATED CABLES AND FLEXIBLE CORDS - CONDUCTORS OF INSULATED CABLES
NFC 32 070 : 2001 AMD 1 2005 INSULATED CABLES AND FLEXIBLE CORDS FOR INSTALLATIONS - CLASSIFICATION TESTS ON CABLES AND CORDS WITH RESPECT TO THEIR BEHAVIOUR TO FIRE
NF EN 60811 1-1 : 96 AMD 1 2001 INSULATING AND SHEATHING MATERIALS OF ELECTRIC CABLES - COMMON TEST METHODS - PART 1: GENERAL APPLICATION - SECTION 1: MEASUREMENT OF THICKNESS AND OVERALL DIMENSIONS - TESTS FOR DETERMINING THE MECHANICAL PROPERTIES
NF EN 60811 3-1 : 96 AMD 2 2001 INSULATING AND SHEATHING MATERIALS OF ELECTRIC CABLES - COMMON TEST METHODS - PART 3: METHODS SPECIFIC TO PVC COMPOUNDS - SECTION 1: PRESSURE TEST AT HIGH TEMPERATURE - TESTS FOR RESISTANCE TO CRACKING
NF EN 60811 1-2 : 96 AMD 2 2001 INSULATING AND SHEATHING MATERIALS OF ELECTRIC CABLES - COMMON TEST METHODS - PART 1: GENERAL APPLICATION - SECTION 2: THERMAL AGEING METHODS
UTEC 32 014 : 83 AMD 1 92 GUIDE FOR CHECKING CONDUCTORS CHARACTERISTICS
UTEC 15 720 : 1975 LOW-VOLTAGE INSTALLATIONS AND CORRESPONDING EQUIPMENT - ELECTRICAL HEATING EQUIPMENT FOR ROOMS. SAFETY REQUIREMENTS - PROVISIONAL REQUIREMENTS.
NFC 15 100 : 2002 AMD 5 2015 LOW-VOLTAGE ELECTRICAL INSTALLATIONS
NF EN 60811-2-1 : 99 AMD 1 2002 INSULATING AND SHEETING MATERIALS OF ELECTRIC AND OPTICAL CABLES - COMMON TEST METHODS - PART 2-1: METHODS SPECIFIC TO ELASTOMERIC COMPOUNDS - OZONE RESISTANCE, HOT SET AND MINERAL OIL IMMERSION TESTS
NF EN 60811 1-4 : 96 AMD 2 2002 INSULATING AND SHEETING MATERIALS OF ELECTRIC CABLES - COMMON TEST METHODS - PART 1: GENERAL APPLICATION - SECTION 4: TEST AT LOW TEMPERATURE

View more information
Sorry this product is not available in your region.

Access your standards online with a subscription

Features

  • Simple online access to standards, technical information and regulations.

  • Critical updates of standards and customisable alerts and notifications.

  • Multi-user online standards collection: secure, flexible and cost effective.

Need help?
Call us on 131 242, then click here to start a Screen Sharing session
so we can help right away! Learn more